Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: Piping Material Brass
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Speed Controller/In-line Type AS2000-N02-X800/AS3000-N03-X800/AS4000-N04-X800 P .G. information Point to Group Specialized Product Flow Characteristics AS3000-N03-X800 AS4000-N04-X800 AS2000-N02-X800 300 800 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 1500 250 600 200 1000 150 400 100 500 200 50 0 0 1 2 3 4 5 6 7 9 8 10 0 0 1 2 3 4 5 6 7 9 8 0 0 1 2 3 4 5 6 7 8 Number
This is a legacy product, and replaced byAF40-N04-27Z-40-A, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, FC, AF MASS PRO 1/2 MODULAR (NPT), 1.21254 lb, ModelPort sizeFluidAmbient and fluid temperatureProof pressureMaximum operating pressureNominal filtration ratingDrain capacity (cm3)Bowl materialBowl guardMass (kg)AF401/4, 3/8, 1/2Air?
Standard Features General purpose pre-filter AFW30-N03-E1 AFW30-N03-E1 AFW30-N03-E1 AFW30-N03-E1 AFW30-N03-E1 AFW30-N04-E1 AFW60-N04-E1 AFW60-N04-E1 Simplex Simplex Simplex Simplex Simplex Simplex Duplex Duplex B C Inlet flow rate Model CFM 6 8 10 15 22 33 44 66 168 222 282 420 624 930 1248 1866 Connection size Model 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 1/2"NPT 1/2"NPT Pipe size
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material
Regulator Unit Combination: Filter Regulator, Port Size: NPT1/2, Filter Rating: 5μm, Compressed Air Quality: -, Maximum Operating Pressure(MPa): 1, Case Material: [Metal] Metal, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Size of Body: 40, Check Valve
This is a legacy product. Please contact us for the latest version.sales@ocaire.com