Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Power cable L3 = 21 x m + 93 Brown: 24 VDC (for solenoid valves/output) White : 0 V (for solenoid valves/output) : The number of Input Blocks + The number of Output Blocks + The number of Power Blocks: m 2 1 5 24 VDC n,m L After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.
Separate cable IZT40-CF Shield wire Semi-stripped terminal Cable length L3 Cable specification Product No. L3(mm) Number of wire /size 12 cables/AWG20(4pcs. ), AWG(8pcs.) Nominal cross section 0.54mm2(4pcs.), 0.09mm2(8 pcs.) 0.96mm (4pcs. ), 0.38mm (8pcs. ) IZT40-CP3 2950 Conductor O.D.
HRLE050 200V N L HRLE090 200V L3 L1 L2 Fig. 3-12 Cable wiring (200V) 3.3 Installation Procedure HRLE Series 3-16 HRX-OM-Z002 Chapter 3 Transport and Set Up 400V L1 L2 L3 Fig. 3-13 Cable wiring (400V) HRLE Series 3.3Installation Procedure 3-17 HRX-OM-Z002 Chapter 3 Transport and Set Up 3.3.4 Preparation and wiring of communication cable Be sure to turn OFF the breaker of the facility power
Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.
M= WexL =5xVaxWxL 3 F3 L3
or knocking of stopper) V (m/s) : Impact speed (during locking or knocking of stopper) Va (m/s) : Average speed L (m) : Distance from C.G. of load M (Nm) : Maximum moment E (J) : Kinetic energy of load g (m/s) : Gravity acceleration (9.8m/s2) Load (N) W1 Moment (N.m) M1=F1x L1 F1