SMC Corporation of America
Elite Part Number Search
Search Results "PF2W511-N06-2"

Body Size: 40, Thread: NPT, Port: 3/4, Drain: None, Flow Direction: Left to Right, Pressure Gauge, Bracket: Round Type Pressure Gauge, w/o Limit Indicator, w/Bracket

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate), Made to Order

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: A (Calibration Certificate), Made to Order: X143

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: Piping Material Brass

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?

2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?