SMC Corporation of America
Elite Part Number Search
Search Results "NCMR150-1100"

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: T (High-pressure Pump)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BW (B + W)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: MT (M + T)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BJ (B + J)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BJMW

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJM (B + J + M)

circuit voltage Surge current immunity Energy immunity voltage (reference Varistor V1mA value) power AC [Vrms] DC [V] 8/20 s [A] 2ms [J] [W] [A] [V] [pF] [V] 100V class TND20V-431K 275 350 10/1 time 195 710 1300 430(387 to 473) 200V class TND20V-471K 300 385 7000/2 time 215 775 1200 470(423 to 517) 1.0 100 400V class TND20V-102K 625 825 7500/1 time 6500/2 time 400 1650 500 1000(900 to 1100

If you want to the SON to automatic ON Binary number (BIN) "0100" to Hexadecimal (HEX) "4" Binary number (BIN) "0" to Hexadecimal (HEX) "0" If you want to the LSP and LSN to automatic ON Binary number (BIN) "1100" to Hexadecimal (HEX) "C" Ex) LSP, LSN and SON to be automatically turned ON, [PD01] = 0C04 38 - * Enabling Stroke end (LSP, LSN) and Servo-on (SON) Signals Set to PD01 to 0C04

Surge current Energy voltage (reference Varistor pulse V1mA voltage immunity immunity value) voltage power AC[Vrms] DC[V] 8/20 s[A] 2ms[J] [W] [A] [V] [pF] [V] 100V class TND20V-431K 275 350 10/1 time 195 710 1300 430(387 to 473) 200V class TND20V-471K 300 385 7000/2 time 215 775 1200 470(423 to 517) 1.0 100 400V class TND20V-102K 625 825 7500/1 time 6500/2 time 400 1650 500 1000(900 to 1100