Auto switches are shipped together (not assembled). 464 Slide Unit/Double Rod Type Series CX2 Specifications Type Air-hydro type Non-lube Fluid Air Hydraulic fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure CX2N10 CX215 CX225 0.15 MPa 0.15 MPa Min. operating pressure 0.10 MPa 10C to +60C Ambient and fluid temperature Refer to Table (1).
Auto switches are shipped together (not assembled). 464 Slide Unit/Double Rod Type Series CX2 Specifications Type Air-hydro type Non-lube Air Hydraulic fluid Fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure CX2N10 CX215 CX225 0.15 MPa 0.15 MPa Min. operating pressure 0.10 MPa Ambient and fluid temperature 10C to +60C 30 to 200 mm/s Refer to Table (1).
Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications 6 10 Bore size (mm) Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed Cushion Stroke adjustable range Port size Air (Non-lube) Size Suction flow rate L/min (ANR) 6 10 1.05 MPa 7 15 0.7 MPa 0.15 MPa 0.1 MPa 10C to 60C (No freezing) 30 to 400 mm/s Rubber bumper
-X 421 CK1 Series Specifications 50 40 63 Bore size (mm) Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa CKG1 Minimum operating pressure 0.05 MPa 10C to 60C Ambient and fluid temperature Piston speed 50 to 500 mm/s Cushion Unclamped side (head end): With air cushion Speed controller Equipped on both ends Lubrication Non-lube +1.0 0 Stroke length tolerance CKP1 Mounting
Specifications Bore size (mm) Item 6 10 15 20 25 32 40 50 63 1.05 MPa Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Stroke length tolerance 0.7 MPa 0.16 MPa 0.15 MPa 0.14 MPa 0.12 MPa 10C to 60C (No freezing) 50 to 400 mm/s 0 to 250 st: , +1.0 0 251 to 1000 st: , +1.4 0 Over 1001 st: +1.8 0 Mounting bracket Grease 2 mounting
REC32 11-REC40 Relief type Vacuum suction type 150 to 700 45 1/8 200 to 1000 150 to 1000 60 50 Air cushion 1/4 Double acting Non-lube (Both sides) Single rod 150 to 700 45 1/8 150 to 1000 200 to 1000 50 1/4 60 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Size Suction flow rate L/min (ANR) 20 25/32/40 Bore size (mm) Item 20/25/32/40 1 2 1.5 MPa 1.0 MPa 0.2 MPa 10C
Note 4) q Ambient temperature: 25C, w Circulating fluid temperature: 20C, e Rated circulating fluid flow rate, r Circulating fluid: Clear water, t Facility water temperature: 25C Note 5) Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is 10C or less.
(including four M10 bolts)8 Accessories Weight (dry state) kg Approx. 136 1 Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating uid temperature is 10C or less. 2 Use uid in condition below as the circulating uid.
/Japanese 1 pc.), Y-strainer 20A 1 pc., Barrel nipple 20A 1 pc., Drain pan for the pump Weight (dry state) kg 171 177 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating uid temperature is 10C or less. Note 2) Use uid in condition below as the circulating uid.
Power supply Nil Rc F G (With Rc-G conversion tting) N NPT (With Rc-NPT conversion tting) 46 3-phase 460 VAC (60 Hz) Specications 1 When the ambient temperature or circulating fluid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 14). 2 Use uid in condition below as the circulating uid.
(including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 180 Approx. 215 Approx. 280 Note 1) When the ambient temperature or circulating uid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1). Note 2) Use uid in condition below as the circulating uid.
(including 4 M10 bolts) Note 10) Weight (dry state) kg Approx. 130 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating uid temperature is 10C or less. Note 2) Use uid in condition below as the circulating uid.
Conditioning Industry Association (JRA GL-02-1994 cooling water system circulating type make-up water). 3 q Ambient temperature: 25C, w Circulating uid temperature: 20C, e Circulating uid rated ow, r Circulating uid: Tap water Refer to the cooling capacity graph on page 10 for details. 4 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating uid temperature is 10C
Refrigerant R134a (HFC) Standard Inlet Air Temperature IDFlE Series 1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1 (Inlet air temperature: 35C, Outlet air pressure dew point: 10C) How to Order IDF 8E 10 Nil A C G K L M R S T Size Symbol Air compressor size 1 1E 0.75 kW 2E 1.5 kW 3E 2.2 kW 4E 3.7 kW 6E 5.5 kW 8E 7.5 kW 11E 11 kW 15E1 15 kW 1 Note that the above values are for reference only.
D 5 port Port #4 on Coil side Voltage 3 110VDC 5 24VDC Manual override B Locking type (Tool required) Thread type N NPT Thread size 02 1/4 Specifications 5-way solenoid valve configuration (for Double acting actuator ) Fluid Air or inert gas Reverse function Normal function Working pressure range 21.8psi to 130psi (0.15 to 0.9 MPa) D-TYPE B-TYPE Ambient & Fluid Temperature 14F to 140F (10C
and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, ET, 10MM MHZ2 SGL-ACT AUTO-SW, .00000 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-10C
and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, ET, 10MM MHZ2 SGL-ACT AUTO-SW, .11440 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-10C
Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, ET, 10MM MHZ2 SGL-ACT AUTO-SW, .29132 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-10C(N)10?13455
18.0 29.5 46.1 KRE12-00 27 M22 x 1 23 90 10.4 26.1 41.5 58.3 2-applicable tubing 19 D MS Plug: KRP Applicable fitting size d Model T A Weight (g) L D KRP-08 KRP-06 6 1 2 3.5 5 KRP-10 KRP-12 8 35 16 10 39 18.5 12 43 20 14 46 22 VMG 8 10 12 Applicable fitting Spatter Cover 1: KR (Applicable tube: FR soft nylon) Applicable fitting size Model Weight (g) D L KR-08C KR-06C 6 0.9 1.0 1.5 1.6 KR-10C
Locations where the ambient temperature exceeds +5~50C range.The metal seal type can be used down to -10C, but take care that solidification of contaminants or water freezing does not take place. 2. Locations where valves will be exposed directly to water drops, cutting oil, etc. 3. Locations exposed to direct sunlight. 4.