Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Series: LEFS, Accuracy: Basic Type, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 550mm, Motor Option: B (w/Lock), Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: RA (10m), Controller: C91
Size: 40, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Series: LEY, Size: 16, Motor Mounting Position: Top Side Parallel, Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 40: 8mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End, Male Thread; 1 Rod End Nut is Included), Mounting: D (Double Clevis, Parallel), Actuator Cable Type, Length: RA (10m), Controller
Series: LEKFS, Size: 40, Motor Mounting Position: L (Left Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 600, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: RA (10), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail
Series: LEFS, Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 1000mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: RA (10m), Controller: C91 (EtherNet
Series: LEFB, Size: 32, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: T (48mm), Stroke: 600mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: K (Body Bottom 2 Locations), Actuator Cable Type, Length: RA (10m)
Series: LEFS, Accuracy: Basic Type, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 700mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: RA (10m), Controller
Series: LEKFS, Size: 40, Motor Mounting Position: L (Left Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 1200, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: RA (10), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)
Series: LEFB, Size: 25, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: T (48mm), Stroke: 500mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: K (Body Bottom 2 Locations), Actuator Cable Type, Length: RA (10m)
Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 400mm, Motor Option: B (w/Lock), Auto Switch Compatibility: None, Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: K (Body Bottom 2 Locations), Actuator Cable Type, Length: RA
Size: 16, Bearing Type: M (Sliding Bearing), Motor Mounting Position: Top Mounting, Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Rotating Torque: J (Basic, 6.6 N.m), Rotation Angle: 320°, Motor Cable Entry: Basic, Entry Right Side, Actuator Cable Type, Length: RA (10m), Controller: C61 [Parallel Input (PNP)], Mounting: 8 (DIN Rail), I/O Cable: 3 (I/O Cable, 3m)
Size: 32, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting