1000 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XB6 Heat resistant cylinder (150C) 100 1000 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XB13 Low speed cylinder (5 to 50 mm/s) 1400 Intermediate strokes are available.
REA REB JIS Symbol Standard Stroke REC Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) Made to Order Specifications CY 25 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 (For details, refer to pages 1851 to 1954.) 4000 CX Symbol Specifications 32 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Long stroke type XB11 5000 40 200, 250, 300, 350, 400, 450, 500, 600, 700
When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 2 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l . 25 Solenoid Valve Flow Characteristics C : Sonic conductance [dm3/(sbar)]
Select from hysteresis mode or window comparator mode. 0.5 s/1 s/2 s (linked with the switch output) Voltage output: 1 to 5 V Output impedance: 1 k7 Voltage output Current output Analog output Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDC Hysteresis External input Display method Indicator light Power supply voltage Current consumption Variable Voltage
When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .
Necessary maintenance space Front: 600 mm Back: 600 mm Top: 600 mm Right side: 600 mm Left side: 600 mm Avoid locations where the ventilation grille is obstructed. Avoid locations where the air dryer will draw in high-temperature air discharged from an air compressor or other dryer. Avoid pneumatic circuits where rapid pressure fluctuations or flow speed changes are generated.
mm 600 mm 600 mm 600 mm 600 mm 3.2.2 7 7.3 IDF-AB500 14 1 IDF60/70/80/90 Series 3-2 IDX-OM-W093 3.2.3 60 65 65 IN OUT (OUT) (IN) IN OUT IDF60/70/80/90 Series 3-3 IDX-OM-W093 3.2.4 12mm 5m8mm SO O S IDF60/70/80/90 Series 3-4 IDX-OM-W093 3.2.5 7.1 0.2m IDF60-20 IDF70-20 IDF80-20 IDF90-20 2) 12AWG (3.5mm 2) 10AWG (5.5mm 2) 16AWG (1.25mm 911 mm 1823 mm IDF60-30 IDF70-30 IDF80
On-stream: 2 to 40oC Spaces needed for maintenance Storage: 0 to 50oC (when there is no Front : 600 mm drain water inside of the piping) Rear : 600 mm Locations where temperature changes rapidly.
Storage: 0 to 50oC (when there is no Spaces needed for maintenance Front : 600 mm drain water inside of the piping) Locations where temperature changes Rear : 600 mm Top : 600 mm rapidly.
mm 600 mm 600 mm 600 mm ( ) 600 mm IDF Series 2-1 2 1 IDX-OM-W026 2 2 2 2 6 6-3 IDF-AB500 14 1 IDF22E,IDF37E,IDF55E,IDF75E 2 2 3 50 50 OUT IN (IN) (OUT) IDF-BP317 1 IDF22E IDF-BP318 1 IDF37E IDF-BP325 1 IDF55E IDF75E 2 2 4 10mm IDF Series 2-2 2 2 IDX-OM-W026 2 2 2 5 6-1 IEC () AC200V 30mA 10A IDF75E 15A 216AWG,3 , 812 1.25 0.2m 30m M3 1.25-3 6.5mm M3 :0.63Nm
Top : 600 mm Locations where strong Right : 600 mm electromagnetic noise is generated (locations Left : 600 mm Locations the ventilation grille of the product where electromagnetic field, can be blocked. strong magnetic field, surge is Place where rejection style air of air generated) Circumstances where static electricity is compressor or other driers (hot wind) is inhaled. produced
Necessary maintenance space Front: 600 mm Back: 600 mm Top: 600 mm Right side: 600 mm Left side: 600 mm Avoid locations where the ventilation grille is obstructed. Avoid locations where the air dryer will draw in high-temperature air discharged from an air compressor or other dryer.
mm 600 mm 600 mm 600 mm 600 mm 3.2.2 7 7.3 IDF-AB500 14 1 IDFC60/70/80/90 Series 3-2 IDX-OM-W095 3.2.3 60 80 80 IN OUT (IN) (OUT) IN OUT IDFC60/70/80/90 Series 3-3 IDX-OM-W095 3.2.4 12mm 5m8mm SO O S IDFC60/70/80/90 Series 3-4 IDX-OM-W095 3.2.5 7.1 0.2m IDFC60-23 IDFC70-23 IDFC80-23 IDFC90-23 16AWG (1.25mm 2) 14AWG (2.0mm 2) 911 mm 1823 mm IDFC60-23 IDFC70-23 IDFC80-23
Necessary maintenance space Front: 600 mm Back: 600 mm Top: 600 mm Right side: 600 mm Left side: 600 mm Avoid locations where the ventilation grille is obstructed. Avoid locations where the air dryer will draw in high-temperature air discharged from an air compressor or other dryer. Avoid pneumatic circuits where rapid pressure fluctuations or flow speed changes are generated.
Spaces needed for maintenance Front : 600 mm Rear : 600 mm Top : 600 mm Right : 600 mm Left : 600 mm Locations the ventilation grille of the product can be blocked. Place where rejection style air of air compressor or other driers (hot wind) is inhaled.
mm) 2feet (600 mm) 2feet (600 mm) 2feet (600 mm) 2feet (600 mm) IDFB Series 2-2 2 2 IDX-OM-W020 2. 2-2-2 6 6-2 2-2-3 122F50 oC 122F 50 oC 2-2-4 IDFB Series 2-2 2 3 IDX-OM-W020 2. 2-2-5 6-1 IEC 2 3 () 812 16AWG1.251.5mm 0.1m 98feet (30m) M3 118138mil (33.5mm) PE IDFB Series 2-2 2 4 IDX-OM-W020 2. 2-3 ()2 (2 ) IDFB Series 2-3 2 5 IDX-OM-W020 3 / 3 / 3-1 INOUT 3-2 ON
0 3 Series VT307 Dimensions Grommet: VT307-G1 Manual override (Non-locking) 2 x 4.5 (For mounting) (42) (33) 54.5 18.6 (17.2) (14.5) (4.5) (4.5) (28) (37) G: 300 H: 600 (Lead wire length) 40.3 13.5 47.2 10.3 3 13 2 1 1/4", 1/8" (Piping port) 16.5 16.7 25.6 (3.2) 33.2 29.5 25 M4 x 0.7 thread depth 7 (Mounting screw) Note) There is also VT307-H1 (lead wire length: 600 mm).
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Nil 6 10 15 20 25 30 50 G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
Fixed (Body) 0.003 to 0.20 N.m or less 0.003 to 0.20 Low rotational torque 0.003 to 0.20 N.m or less Low rotational torque Rotary Joint Turntable Allowable RPM 600 to 3000 min-1(r.p.m) Allowable RPM 600 to 3000 min-1(r.p.m) 600 to 3000 Drive (Adapter plate) Drive motor Application of adapter plate drive Not suitable for transmission of drive Series MQR Low torque Metal seal type Rotary joint