Bar type Bar length Sensor Emitter cartridge type/Emitter material Bar length 300 mm 380 mm 620 mm 780 mm 1100 mm 1260 mm 1500 mm 1900 mm 2300 mm Symbol 300 380 620 780 1100 1260 1500 1900 2300 Without sensor Autobalance sensor [Body-mounting type] Nil E F G Symbol Nil C S J K Emitter cartridge type Emitter material With feedback sensor Autobalance sensor [High-precision type] Tungsten Silicon
Outside of cylinder tube with hard chrome plated 32 Non-lubricated exterior (with dust seal) 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 1500 40 Switch rails on both sides (with 2 pcs.)
Standard Stroke / Bore size (mm) Maximum stroke (mm) Standard stroke (1) (mm) Rod Boot Material 20 25 32 40 1000 1500 25, 50, 75, 100, 125, 150 200, 250, 300 Symbol Rod boot material Maximum ambient temperature 2000 70C 2000 J Nylon tarpaulin 110C K Note 1) Intermediate strokes other than listed above are produced upon receipt of order.
st: JIS Symbol Standard Stroke Maximum manufacturable stroke (mm) Minimum stroke (1) Bore size (mm) Standard stroke (2) (Recommended) (mm) 20 150 Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
Standard Strokes (mm) Bore size Standard stroke Note1) Maximum manufacturable stroke Note 2) 1 Cylinders with rubber bumper have no bumper. 2 Only compatible with cylinders with rubber bumper, but has no bumper. 20 25, 50, 75, 100, 125, 150, 200 201 to 1500 25 32 40 50, 63 80 100 25, 50, 75, 100, 125, 150, 200, 250, 300 301 to 1500 Refer to pages 355 to 361 for cylinders with auto switches
Connector assembly 6 43 Connector lead wire length (mm) Blanking plate with connector 4-wire 2-wire 43 44 Nil 300 600 1000 2000 3000 Nil 300 20 25 30 2000 Connector A C B 6 10 20 30 6 10 15 600 2500 Nil Without connector With connector/2-wire With connector/4-wire 1 2 1000 3000 A Lead wire color: Black Lead wire color: Red 1500 B Lead wire color: White 24AWG Blanking plate with a connector
The value displayed is not multiplied by the electronic gear (CMX/CDV). 1500 to 1500 Analog speed command voltage Analog speed limit voltage 10.00 F V (1) Torque control mode Analog speed limit (VLA) voltage is displayed. to 10.00 (2) Speed control mode Analog speed command (VC) voltage is displayed.
(Note) The value will be -1500 to 1500 kpulse/s when kpulse/ -9 s 9 inputting command pulse.
. -4i -2 .44 -.4 5000 4m0 40 30 m 2500 2000 1500 12.5 1 0 ===-rt=='-t {E -.2-_L-2. d r / .zx. :2. 4 6 (mm) Fig.6.14 Theortical Force of pneumatic cylinders, trom 2.5 to 30 mm (left and top scales) and from 32 to 300 mm (right and bottom scales) for 19,.1-a"ng,5 bg!.
500, 600, 700, 800 Oversized rod cylinder XB5 125 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (150C) XB6 Intermediate strokes are available.
MRQ Mass Rotating angle Size Basic mass (g) Flange (g) Add'l stroke mass (g/mm) 80 to 100 1400 4 500 32 170 to 190 1500 80 to 100 2100 40 5 500 170 to 190 2300 Calculation: (Example) MRQBS32-50CA Basic mass 1400 g 4 x 50 = 200 g Stroke additional mass Total 1600 g For the mass of auto switch alone, refer to pages 767 to 809.
[oC] correction coefficient Less than 1000m 45 1.00 1000 m or more Less than 1500 m 42 0.85 1500m or more Less than 2000m 38 0.80 2000m or more Less than 2500m 35 0.75 2500m or more Less than 3000m 32 0.70 Installation/Operation in an ambient temperature of 10 oC or less Use ethylene glycol solution at a concentration of 15 % for the circulating fluid.
N Nil Rc 3 1 0 14 to 60 l/min 20 to 1500 l/min 36 to 2600 l/min NPT Specifications Water/Non corrosive liquid Copper alloy Fluid Stainless steel 304 Liquid, which do not corrode stainless steel 304. Max. pressure 1 MPa 1.75 MPa Water resistance Insulation resistance 100 M (500 DC by megameter) 1500 VAC for one min.
MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Handling Warning 15. In locations where strong impacts or vibrations occur 16.
Operating time 20 s 30 s HRZ 10 s Voltage HRZD 5 s Min. 2 s HRW 1 s 0.5 s dV dt HECR = Voltage increase ratio 0.2 s 0.1 s dV HEC 0.05 s 0.02 s Time HEB 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 dt HED Current (% for chiller main breaker volume) < For option B [With earth leakage breaker]> 3.
Refer to gauge guide (P.94, 95). qIN wOUT erGauge port (Outlet) Specifications AK9202 1 to 30 psig (0.007 to 0.2 MPa) Ak9215 5 to 150 psig (0.034 to 1.0 MPa) Select compatible materials of construction for the gas Vacuum to 300 psig (2.1 MPa) 450 psig (3.1 MPa) 1500 psig (10.3 MPa) 40 to 160F (40 to 71C) (No freezing) 1.6 1 x 10-10 Pam3/sec NPT 3/4 inch 7 psig (0.048 MPa) rise in delivery
AS301FS, AS311FS AS401FS, AS411FS Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable tubing
st: JIS Symbol Standard Stroke Maximum manufacturable stroke (mm) Minimum stroke (1) Bore size (mm) Standard stroke (2) (Recommended) (mm) 20 150 Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.