10 10 10 10 RLQ D-A59W 17 17 17 17 17 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL MLU D-A3/A44 D-G39/K39 BS1-125 BS1-140 BS1-200 BS1-160 BS1-180 12 13 7 7.5 8 MLGP D-Z7/Z80 D-Y5/Y6 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5/F59F D-F5W/J59W D-F5BAL/F5NTL BS4-125 BS4-125 BS4-160 BS4-180 BS4-200 ML1C 5 5 5.5 6 6 D-G39/K39 11 11 10 10 10 [Mounting screw set made of stainless steel] Since this is a guideline
Through-hole: CQ2YB/CDQ2YB Both ends tapped style: CQ2YA/CDQ2YA CDQ2YA RE A B Both Ends Tapped (mm) Bore size (mm) O1 R O1 thread REC R R 32 M6 x 1.0 10 40 M6 x 1.0 10 CX 50 M8 x 1.25 14 CY MQQ M RHC H thread effective depth C U 4-N through 8-O counterbore Q F 2-P (Port size) (Rc, NPT, G) MK(2) I RS Q G RS H A 22 D M E Z 11 Lead wire min. bending radius 10 RZQ Auto switch D-A7, A8 MI W S
500 Up to 600 Up to 600 Up to 700 Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22
Model AS1ll1FS-M5l AS2ll1FS-01 AS2ll1FS-02 AS3ll1FS AS4ll1FS Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
PC09]MOl-LG 10 2 MO2 CN3-14 [Pr. PC10]MO2-LG 10 (D) No. I/F DICOM CN3-5 DC24V(DC24V10% 150mA) DC24V CN3-10 DC24V I/F DOCOM CN3-3 EM1LG DC24V DC24V LG CN3-1 MO1MO2 CN3-11 SD 3 22 3 3.6 OFFON CPU () ON ON OFF OFF ON ON OFF OFF ON ON ON () OFF () OFF 1s ON ON () OFF 50ms 60ms () OFF 50ms 60ms .
Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable voltage fluctuation should be within the following range. 24 VDC: 7% to +10% 12 VDC: 4% to +10% Made to Order (Refer to page 24 for details.)
Electrical entry F: Plug-in type Option Port size Nil 01 Without sub-plate Rc 1 8 50 01 F Z VZS2 1 2 Plug-in 5 G 50 VZS2 Non plug-in 2 01 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil rated voltage Symbol Thread type 1 2 3 2 position single 100 VAC, 50/
CKZ-50A009 ACA213M 150.0 1.0 50 mm offset: Machined 25 mm offset: Machined A A B B C C 8F7 through +0.028 +0.013 D 8F7 through +0.028 +0.013 D E E 200.03 F G F 10 200.03 10 G 300.025 300.025 11 through H 300.025 300.025 I 11 through H 250.05 J 250.05 I M6 x 1.0 45 R45 500.05 6.5 18 M6 x 1.0 10 750.05 3 R25 10 R6 1 1 6.5 R25 19 18 19 R25 19 [mm] R6 19 [mm] Model NAAMS code A B C D E F G H
A B 32 32 41 44 F 7.5 7.5 9 11 L A B 22 22 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 A B 17 17 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 12 16 20 25 45.5 13.5 25.5 5 to 30 5 to 30 5 to 50 5 to 50 35 to 200 35 to 200 75 to 200 75 to 300 6 8 7 12 6 8 10 12 25 29 36 40 M4 x 0.7 6.5 6.5 9 9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 20.5 M3 x 0.5 32 38 47 52 5 6 8 10 15.5 20 3.5 3.5 5.4 5.4 45.5 13.5 25.5 34 M4 x 0.7
Size 40 L L 2 K G1 0 0.030 F D B 4 K N V1 Body (B) T V2 M S Body (A) h Key dimensions L1 b C G2 J F h (h9) L1 b (h9) Model L 2 x R A CRB2B;40 4 0 0.030 4 0 20 E 0.030 CRB2B=10-=S CRB2B==-=SE/DE
B C D E F IDF1D-1 to 11C-1 IDU3D-1 to 11C-1 200, 220 230, 240VAC (50Hz) 200 to 260VAC (60Hz) IN PUT VOLUTAGE SELECTOR 100VAC (50Hz) 100 to 110VAC (60Hz) Single phase Single turn IDF-TR500-2 500VA 118 140 163 70 112 6 5.5 x 10 (Long hole) E D 4-F IDF15C-1 IDU15C-1 Input cord 2m IDF-TR1000-2 1kVA 118 140 208 70 157 10 IDF-TR -3, 4 C VOLUTAGE SELECTOR Dryer Weight (kg) Part No.
T kit 12 stations C8 (For 8) C10 (For 10) C12 (For 12) Rc 1/4 Rc 3/8 Rc 1/2 Option 2.24 F kitD-sub connector T kitTerminal block box L kitLead wire S kitSerial transmission VV5Q41VQ400 VQ401 Side L kit Except solenoid valve weight L kit 16 stations VQ4000 Direct exhaust with silencer box S kit 10 stations VQC Rc 1/4 Bottom Note) For details about inch-size One-touch fittings and other
9 9 11 11 38 41 50 52 66 76 51 54 65 67 86 96 10 10 12 14 18 20 21 24 33 37 47 55 7 9 11 11 12.5 13.5 18 22 30 35 40 50 26 28 32 40 50 60 31 35 45 50 60 70 32 36 45 50 63 71 8 10 12 12 14 15 10 11 12 15 15 19 32 40 50 63 80 100 11 11 15 15 18 18 10 12 16 16 20 20 21 24 33 37 47 55 8.5 8.5 10.5 10.5 11.5 12.5 10 10 12 12 14 15 6.6 6.6 9 9 11 11 38 41 50 52 66 76 18 22 30 35 40 50 31 35 45
, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Current consumption 15 mA or less (with no load) Analog output 1 to 5 V (with rated pressure range), 0.6 to 1 V (with extension analog output range), Output impedance: Approx. 1 k Output specification Accuracy (Ambient temperature at 25C) 2% F .S. or less (with rated pressure range), 5% F .S. or less (
N T Rc F: With foot bracket G NPT SYJ NPTF Port size VK 01 1 8 Light/Surge voltage suppressor Note) Bracket is not mounted.
> [F 2] [F 1] OUT1(2729) 1[-], [F 3] <> [F 3] [F 3] -30No.PS-OML0002CN-G [F 4] <> [F 4] 1000 100 [F 4] [MPa]/[kPa(ZSE)]/[kgf/cm 2]/[bar]/[psi]/[inHg] ([kgf/cm 2]/[bar]/[psi]/[inHg] 26[F 0] -31No.PS-OML0002CN-G [F 5] <> [F 5] [F 5] -32No.PS-OML0002CN-G OUT1 AP1 (OUT1AP1 1AP2) OUT1 OUT1 OUT1 A1L A1H (A1L 1AP2) OUT2 P_1 H_1(n_1 H_1)AP2 (OUT2AP2 1 ) OUT2 OUT2OUT1OUT2
Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) CC 70 Lateral load F (N) RB 60 0.4 MPa 50 J 40 2.
Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) CC 70 Lateral load F (N) RB 60 0.4 MPa 50 J 40 2.
Rod clevis: GKM (ISO 8140) l1 [mm] Bore size [mm] Part no. e b d f h11 (Shaft) f H9 (Hole) l1 c (Min.) a (Max.) 32 GKM10-20 M10 x 1.25 10+0.5 +0.15 40 10 10 52 20 20 40 GKM12-24 M12 x 1.25 12+0.5 +0.15 48 12 12 62 24 24 50, 63 GKM16-32 M16 x 1.5 16+0.5 +0.15 64 16 16 83 32 32 80, 100 GKM20-40 M20 x 1.5 20+0.5 +0.15 80 20 20 105 40 40 125 GKM30-54 M27 x 2 30+0.5 +0.15 110 30 30 148 54 55
(ISE70 series only) prevent moisture from getting into the piping. -30No.PS-OMH0003-F Reference No. Problem Possible cause Investigation method Countermeasure Check if the power supply voltage is within the range of 12 to 24 VDC. (ripple 10%) Supply power supply voltage of 12 to 24 VDC (ripple 10%) Incorrect power supply Check the wiring to the power supply.