Exhaust Cleaner Series AMC How to Order Ensures clean plant air and reduces noise pollution; Over 35 dB (A) noise reduction Over 99.9% oil mist removal 5 1 0 AMC 06 Thread Body size Suffix std. 1 4 std. 3 8 std. 3 4 1 std. 1 std. 1 2 2 std. 2 3 5 6 8 9 B With bracket 1 Male thread D Drain piping (Except AMC220) (1) (2) 2 Female thread Note 1) Female thread: Available only AMC220, 320, 520
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
VK300-82-2-01 100 VAC V100 VK300-82-2-03 110V 110 VAC 200 VAC 220 VAC VK300-82-2-02 200V VK300-82-2-04 220V S070 240V 6V 12V 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal VQD VQD-V Light (Built-in connector) Marking Circuit with light AC Circuit diagram 12 VDC or less Circuit diagram 24 VDC or more Circuit
Ph (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) * 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max. 50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (Ph4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L) Max.200 Max.70 Calcium hardness (mgCaCO3/L) Max.150 Max.50 Standards Ionic silica (mgSiO2/L) Max.50 Max.30 Iron (mgFe/L) Max.1.0 Max.0.3 Copper
mm/sec Cylinder stroke: 200 mm AQ The set pressure can be either fixed or variable.
DXT170-176-2-01 DXT170-176-2-02 100V 200V 100 VAC 200 VAC DXT170-176-2-03 110V 110 VAC DXT170-176-2-04 220V 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240V 6VD 12VD 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC circuit DC circuit NL: Neon bulb R: Resister D: Protective diode LED: Light emitting diode R: Resistor 4
mm/sec Cylinder stroke: 200 mm AQ The set pressure can be either fixed or variable.
Relay, PLC 100 V Reed switch Solid state switch PLC 100 V, 200 V Relay, PLC 12 V Yes Yes 24 V 2-wire Terminal conduit PLC 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V 24 V IC circuit Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC 12 V 3-wire (NPN
Relay, PLC 100 V Reed switch Solid state switch PLC 100 V, 200 V Relay, PLC 12 V Yes Yes 24 V 2-wire Terminal conduit PLC 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V 24 V IC circuit Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC 12 V 3-wire (NPN
Use pilot ports and sensor (breathing) ports as indicated below. (2) Lead wire color Rated voltage (1) (2) DC (Type B only) Red Black 100 VAC Blue Blue Sensor (breathing) port PB port PA Port 200 VAC Red Red N.C. Exhaust Exhaust Pressure Other AC Gray Gray N.O. Exhaust Pressure Exhaust There is no polarity.
V 2-wire PLC 12 V No 200 V or less 24V Terminal conduit Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com R L 10 8 5 4 ZZMA Stations 06 ZL 10 10 8 6 ZZMA Stations 06B ZY R L 10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2. ZF ZP ZCU How to Order Ejector Manifold AMJ ZZMA 06 06 R Misc.
Display LCD LCD with backlight LED Pressure setting range 101 to 10 kPa 101 to 0 kPa Maximum operating pressure 200 KPa Operation indicator light (Lights up when ON) Green OUT1: Green OUT2: Red Response frequency 200 Hz (5 ms) Hysteresis mode Variable (3 digits or more) Variable (can be set from 0) Hysteresis Window comparator mode Fixed (3 digits) Fluid Air, Non-corrosive gas Temperature
(Including O-ring for element) FH FH With relief valve Without relief valve Model Element size 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) HOW FH990-04/06 FH990-08/10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28/32 65 x 90 82 x 133 104 x 177 104 x 177 132 x 212 132 x 212 155 x 193 EM520-105N EM620-105N EM720-105N EM820-105N EM920-105N
D 200 AS Type adjustable by flat head screwdriver Body size 100 200 205 300 400 M5 standard Applicable tubing O.D. 1/8 standard Inch size Metric size 1/4 standard 3.2 3/8 standard 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 1/2 standard 4 5/32" 6 3/16" 8 1/4" With One-touch fittings 10 5/16" 12 3/8" 1/2" Use 1/8" tube. 15-9-81 8 Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa
Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of
) Air N2 1 L/min 10 100 2 L/min 20 200 5 L/min 50 500 PF3A7 H Thermal type (Platinum sensor) 2 L/min 30 3000 p. 9 Air N2 PFG300 5 L/min 60 6000 p. 14 12000 Bypass flow type 10 L/min 120 0.2 PFM 0.01 L/min 10 Dry air N2 Ar CO2 0.5 25 Thermal type (MEMS) 0.1 L/min 1 50 2 100 PFMB 2 200 Thermal type (MEMS) 5 500 Dry air N2 1 L/min Bypass flow type 10 1000 PFG300 20 2000 PFMC 5 500 Thermal
Standard stroke (mm) 60C Nylon tarpaulin 110C Neo plain cloth MXQ 25, 50, 75, 100, 125, 150, 175, 200, 250, 40 Maximum ambient temperature for the rod boot itse 300, 350, 400, 450, 500 MXF 25, 50, 75, 100, 125, 150, 175, 200, 250, 50, 63 300, 350, 400, 450, 500, 600 MXW 25, 50, 75, 100, 125, 150, 175, 200, 250, 80, 100 300, 350, 400, 450, 500, 600, 700 MXP Minimum stroke of auto switch