specifications Model With bracket With built-in silence K L M N P Q R S T U V W X Y AVA2000-02--A 30 50 51.5 44 5.5 10 66 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 14 AVA3000-03--A 41 50 53.5 46 5.5 15 70 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 19 AVA4000-04--A 50 60 64 54 8.5 18 90 3.2 39 74 M5 x 0.8 Depth 6.5 4 Width across flats 22 AVA5000-06,10--A 70 75 70 60 11
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Pressure switch Power supply Thermometer Solenoid valve Equipment for test Control circuit
Internal circuit and wiring example Z/ISE40A(F)Output specification -S/-R (Analogue output mode) Switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less R: Analogue output 1 to 5 V Output impedance 1 k S: Analogue output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -S/-R (
ALARM is expressed as negative-logic circuit. (2) Positioning Operation (4) Stop by the STOP Signal 24 V 0 V 24 V 0 V Power supply Power supply ON OFF ON OFF IN0-3 IN0-3 Input Input ON OFF OUT0-3 STOP Output ON OFF BUSY OUT0-3 Release Hold BUSY External lock Output ALARM 0 mm/s Speed Positioning operation Release Hold External lock OUT0-3 output signals are ON in the same state as the input
g = 9.8m/s m = 0.1kg x = 10 L = 50mm V = 12m/min Procedure2 Confirmation of impact Obtain the total amount of the work piece.
Switch return position (OFF) D-F9N D-F9B D-F9BA D-F9NW D-F9NV D-F9BV D-F9NWV MHS O MHY2-10D 3 8 13 6 1 1 8 S Hysteresis O MHY2-16D 3 8 13 7 1 1 8 S MHC2 Switch operating position (ON) O Hysteresis MHY2-20D 5 10 4 5 S Switch operating position (ON) MHT2 O Switch return position (OFF) MHY2-25D 3 9 3 3 S MHY2 D-F9NW(V) D-F9BA MHW2 D-F9N(V) D-F9B(V) Red light at ON Red light at ON Green
Dedicated Controller/LC1 P.73 Controller setup software P.80 Dedicated teaching box P.82 Options P.85 Dedicated Regenerative Absorption Unit/LC7R P.86 Non-standard Motor Compatible Drivers P.89 73 2 Series LC1 Controller Single Axis Type Built-in AC Servo Driver Series LTF: Standard Motor Compatible How to Order 2V LC1 F 1 H 1 L 3 Number of axes Mounting bracket 1 3 5 1 axis M3
speed Symbol A M5 50 to 1000mm/s Relief port size Piston speed C85 Auto switch can be mounted.
Refer to "Auto Switch Hysteresis" on P.24. Note 2) Refer to P.22 and 23 for auto switch specifications.
V,12 V Magnetic field resistant (2-color indication) 2-wire (Non-polar) 3-wire (NPN equivalent) IC circuit A96V A96 5 V A72 A72H Grommet 200V 100V Reed switch A93V A90V A93 A90 12 V IC circuit 100 V or less Relay, PLC 5 V,12 V 12 V 2-wire A73C A80C A79W 24 V Connector IC circuit 24 V or less 5 V,12 V Diagnostic indication (2-color indication) Grommet Solid state auto switches
P 45.5 24 32 1.8 (Bleed port) With fiflter (80 mesh) R2 21 2 position double: SYJA5220-M5 2 position double: SYJA5240-01 2-4.3 44 2-M5 x 0.8 (Pilot port) 2-M5 x 0.8 (Pilot port) (For mounting) A B 1 11 1 5 A B 1 24 A B 1 2-2.6 10 R P (For manifold mounting) 19 4 2 37.5 47 42 15 54 54 Manual override 24.5 23 20 11.5 3 2-2.6 (For mounting) 11 Manual override 2-1.8 (Bleed port) 46.5 1/8 33.5
The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1)/t l/min(ANR) V : Inner volume = cm3 P : Absolute pressure = {Operating pressure (MPa) + 0.1} t : Operating time = s CRB2 CRBU2 CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.
V = 1.4 x Va V = 1.4 x 250 V = 350 mm/s Va M1E = 1/3 x FE x Z = 1/3 x 188.7 x 100/1000 = 6.3 [Nm] (A) M1E (z) m x g Z 3A = M1E/M1max = 6.3/17.1 = 0.37 Find the value M1Emax when Va = 350 mm/s from Graph (11) v. Va Examine M3E.
V (mm/S) Graph (1) Confirm that V = 420 and W = 0.2 do not exceed the values in Graph (1).
OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) JEMANET (JPCN-1) Mitsubishi Electric Corp.: CC-LINK System Rockwell Automation: Allen Bradley Remote I/O (RIO) System NKE Corp.: Uni-wire H System 1 to 16 stations Kit L Kit L BB C D F1 J1 J2 K Q R1 R2 U V G H 3 to18 stations SD S Simple specials are available with SMC Simple Special System.
T 2 x P (Rc, NPT, G) Q B S W U K L E R I AA AL AP X A AB J V Y + Stroke Z + Stroke 8 x AF AC AD AE (mm) Bore size (mm) 20 25 32 40 50 Stroke range (mm) A AA AB AC AD AE AF AL AP B C D E F G H I J K L M N 90 11 11 7.5 75 30 6 25 108 15 60 92 5.5 30 55 60 80 25 45 M5 x 0.8 depth 10 M8 x 1.25 depth 14 75, 100, 125, 150, 200 9.5 depth 6 100 14 13 7.5 85 30 6 30 130 17.5 65 113 6.6 35 65 70 100
(mm) 26 20 16.5 14 C 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 13<10> 20<18> 20 20 GA 50 40 40 35 H 8 6 6 5 H1 19 17 17 13 B1 47 38 31 26 I 187 175 173 163 ZZ M6 x 1 depth 12 M5 x 0.8 depth 8 M5 x 0.8 depth 7.5 M4 x 0.7 depth 7 J 27 19.5 19.5 15.5 AL Bore size A M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 MM 44 35.5 29 24 NA 1/8 1/8 1/8<M5 x 0.8> 1/8<M5 x 0.8> P 9 7 7 7 RA 87 95 93 93 S 6 5.5 5.5
wire (NPN equivalent) 100 V 12 V Relay, PLC 2-wire 24 V A90V No IC circuit 5 V,12 V 100 V or less 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.