These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion. Pressure Setting 2. Do not use in an environment where a strong magnetic field is present. Caution The influence of the external magnetic filed may cause the switch to malfunction. 1.
These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion. Pressure Setting 2. Do not use in an environment where a strong magnetic field is present. Caution The influence of the external magnetic filed may cause the switch to malfunction. 1.
If the application does not satisfy the safety requirements, add an external circuit for safety reasons as required. 12 - (2) Output Signals Signal Pin No. Name Function Servo alarm output signal ALM+ ALM3 4 Turns OFF when an error is detected. /BK+ (/SO1+) /BK(/SO1) Controls the lock. The lock is released when the signal turns ON.
To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.
For details, refer to pages 3-7-19 and 3-7-20.
Accessory None (Standard) With bracket (Except IDG1) Nil B Note) When symbol B is indicated, a bracket assembly with a part number shown in the table below is included as an accessory.
Note 2) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. When using it as a reverse pressure valve, P port regulation is not allowed to use. Note 3) When using a perfect spacer, assemble a valve, a spacer regulator and a perfect spacer in this order to use it.
Within the reciprocating movement of the actuator, if only the movement in one direction must be controlled, connect an airhydro unit to the cylinder piping port of the control direction as shown in Fig. (1).
Manual Override How to Use L/M Plug Connector Caution Warning Attaching and detaching connectors Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option.
Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of moisture can cause malfunction of pneumatic equipment such as rotary tables. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator. 4.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. 4. Keep wiring as short as possible.
Holding pressure (including vacuum) Since valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel. 4. The valve cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve.
Note that power daisy chaining supports a maximum of 20 MPCs in one power group. This does not mean that you cannot have more than 20 MPCs connected to a single supply. More MPCs can be supported as long as the supply can source enough power to support multiple chains of MPCs. Each MPC uses about 7 watts of power when moving.
If there is no need to be used in an air-tight circuit, remove the packing at the lid of the tank to use it as an open tank. Do not mistake IN for OUT of recirculating fluid radiating water.
Specifications Specifications Type Bore size (mm) Action Fluid Type Bore size (mm) Action Fluid Spring assisted type 6, 10, 16, 20, 25, 32, 40 Double acting Air Spring assisted type 10, 16, 20, 25 Double acting Air Dimensions are the same as the single acting type. Note) Dimensions of 6 to 25 are the same as the standard type.
Specifications Specifications Type Bore size (mm) Action Fluid Type Bore size (mm) Action Fluid Spring assisted type 6, 10, 16, 20, 25, 32, 40 Double acting Air Spring assisted type 10, 16, 20, 25 Double acting Air Dimensions are the same as the single acting type. Note) Dimensions of 6 to 25 are the same as the standard type.
When the conduit type is used as equivalent to an IP65 enclosure, install a wiring conduit, etc. 9. When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged.
Action D Double acting Cylinder stroke Bore size (mm) Standard stroke (mm) Mounting Bore size 10, 20, 30, 40 10 Through hole & double end tapped (standard) Foot type Front flange type Rear flange type Double clevis type B L F G D Note) 10 16 20 25 28 10mm 16mm 20mm 25mm 28mm 10, 20, 30, 40, 50, 60 16 10, 20, 30, 40, 50, 60 20 10, 20, 30, 40, 50, 75, 100 25 10, 20, 30, 40, 50, 75, 100 28 Note
Wiring Specs 20 20 Applicable up to 20 Solenoid M A N I F O L D O P T I O N S PORT PLUGS Applicable Fitting Size d A L D Model 16 32 6 KQP-04 4mm 16 32 6 KQP-03 5/32 18 35 8 KQP-06 6mm 18 35 8 KQP-07 1/4 20.5 39 10 KQP-08 8mm 20.5 39 10 KQP-09 5/16 Inserts easily into an unused cylinder port and/or SUP/EXH Ports.