SMC Corporation of America
Elite Part Number Search
Search Results "HRSH100-AN-40-M"

69 26 M48 x 1.5 t +0.15 0 m 40 NTH-040 22 25.4 21 10 M16 x 1.5 C 50 NTH-050 27 31.2 26 12 M20 x 1.5 Df8 63 H 0 0.15 NTH-060 32 37 31 14 M24 x 1.5 C-series 80 NTH-080 41 47.3 40 17 M30 x 1.5 C L 100 NTH-100 55 63.5 54 20 M39 x 1.5 Material: Rolled steel Bore size (mm) C L m t H Df8 Part no. 32, 40 0.016 0.043 16 CDH-04 1 62 2.5 4.8 14 50 0.016 0.043 20 CDH-05 1 76.5 3.5 4.8 18 0.016 0.043

Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 6-3-13 for details.

Applicable for use in an environment with water splashing such as food processing and car wash equipment, etc. Specifications Action Double acting, Single rod Caution Bore size (mm) 32, 40, 50, 63, 80, 100 1. Do not use the air cylinder as an air-hydro cylinder. This will cause an oil leak. 2. Install a rod boot without twisting.

Add M to the end of the part number for 1 m, L for 3 m, and Z for 5 m. Example) -2M9NL !

Description Size 1 Valve Rc1/2 2 Valve Rc1 3 Y-strainer (#40) (Accessory)* Rc1 4 Flow meter Prepare a flow meter with an appropriate flow range. 5 Valve (Part of thermo-chiller) Rc1/4 6 Pressure gauge 0 to 1 MPa 7 Y-strainer (#40) or filter Rc1/2 8 Valve Rc3/8 9 Y-strainer (#40) or filter Rc3/8 * If foreign objects of 20 m or larger may enter, install a particle filter separately.

3 3 m B 15 m* LER 5 5 m C 20 m* 2N LECP2* Programless type (With stroke study) *1 The standard cable should be used on fixed parts.

m m m d Dd9 d Dd9 0.1 0.3 NX +0.2 0 A1 U1 L 7 12 Material: Pin and snap ring both SUS304 Material: SUS304 Material: Pin and snap ring both SUS304 Part no.

) 4-wire (NPN) 5 V, 12 V IC circuit Magnetic field resistant (2-color indication) P5DW 40 to 100 2-wire Lead wire length symbols: 0.5 mNil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Solid state switches marked with are produced upon receipt of order.

2 1.5 m 3 3 m SI unit output polarity, End plate type (S6m) Refer to page 63.

40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)

(Type 20 manifold) 10 SYJ3 2 5 M 1 M3 3 Body ported Base mounted (4 port) 2 3 SYJ3 10 3 5 M (Manifold use only) Base mounted (5 port) 10 4 M 2 5 3 SYJ3 Clean series 4 port Manual override Port size Body option Nil: Non-locking push type Nil: Without sub-plate 3: Main/Pilot valve common exhaust type For type 31, S31, 32, S32 manifold 5 port R port P, E port (With gasket and screws) D: Push-turn

(R)-L-01 M plug connector (M): SX3 40(R)-M-01 Manual override (Press and turn for the locking type.)

) 4-wire (NPN) 5 V, 12 V IC circuit Magnetic field resistant (2-color indication) P5DW 40 to 100 2-wire Lead wire length symbols: 0.5 mNil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Solid state switches marked with are produced upon receipt of order.

IA 25 43 BY Max.Wc 40 Ws 35 13 30 D 36 Width across flats K Width across flats 44 R15 0.050 0.093 +0.027 0 Shaft: 12d9 Clevis width CLK1A: 16.5 F +0.3 0 +0.4 0 Hole: 12H8 Z + Stroke S + Stroke 1.5 27 CLK1B: 19.5 40 57 97 ZZ + Stroke 2 (mm) Symbol BX BY D F GA GB IA K L M N S W Wc Ws Z ZZ Bore size 40 56 54 16 44 77 10 47 14 55 M12 x 1.5 86 112.5 5 39 27.5 114 228 50 64 64 20 55 78.5 10 58

Description Size 1 Valve Rc1/2 2 Valve Rc3/4 3 Y-strainer (#40) (Accessory) Rc3/4 4 Flow meter Prepare a ow meter with an appropriate ow range. 5 Valve (Part of thermo-chiller) Rc1/4 6 Y-strainer (#40) Rc1/2 7 Pressure gauge 0 to 145 psi (0 to 1 MPa) 8 Y-strainer (#40) or lter Rc3/4 Cable Specications Power supply and signal cable should be prepared by user.

Mixed single and double wiring are available as an option. Refer to the below special wiring specifications (option). Sheath Color: White Lead wire length 0 1 2 0.6 m 1.5 m 3.0 m Electrical characteristics Item Property Conductor resistance /km, 20C 65 or less Voltage limit V, 1 minute, AC 1000 Polarity Terminal no.

Lead wire length symbols: 0.5 mNil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z Auto switches marked with are made-to-order specifications.

Guide for Using MY3B Side Support Guide for Using MY3A Side Support 100 100 90 90 (1800) (1900) 80 80 m 70 70 MY3A63 Weight w (kg) 60 60 MY3B63 Weight w (kg) l 50 50 (1300) (1400) 40 40 MY3B40 MY3A40 30 30 m 20 20 (1000) (1100) l MY3B25 MY3A25 10 m 10 (900) (1000) MY3A16 MY3B16 0 0 4000 3000 2000 1000 0 4000 3000 2000 1000 0 Support spacing l1 (mm) Support spacing l1 (mm) Note) A side support

L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN D-P5DWL type can only be mounted for bore sizes 40, 50, 63.