SMC Corporation of America
Elite Part Number Search
Search Results "CNA2D100TN-350-D"

Magnet: None, Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: None, Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 500mm, Bellows/Cushion: J (Nylon Tarpaulin+Cushion Both Sides), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC4 (w/Heavey Duty Scraper)

Magnet: None, Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC4 (w/Heavey Duty Scraper)

Magnet: None, Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 337, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Magnet: None, Mounting: Double Clevis, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Coil Scrapper

Magnet: None, Mounting: Double Clevis, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Heavey Duty Scraper

Magnet: None, Mounting: Double Clevis, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Coil Scrapper

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 337, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

C F G D E F G D T F G D F F G E S F G E L F G E T F G G S F G G L Fluid name Applicable element type, material Nominal filtration accuracy (m) Fiber element Polypropylene 10 Industrial water Fiber element Polypropylene 20 Water for cleaning Fiber element Polypropylene 20 Water Fiber element Cotton 10 Fragrances Micromesh element Stainless steel 316 10 Hot water Micromesh element Stainless

(max. 20 stations) 3 SY3000 5 SY5000 Connector mounting position A, B port size Symbol Mounting position U U side SY5000 SY3000 D D side Symbol Port size 4 One-touch fitting C4 Symbol Port size 4 One-touch fitting C4 6 One-touch fitting C6 Mixed M 6 One-touch fitting C6 Valve stations 8 One-touch fitting C8 Mixed M Stations Symbol Note Single wiring specifications (up to 16 solenoids are

Symbol Applicable stations Mounting position U side D side Both sides M Special specifications 2 to 10 stations 2 to 10 stations 2 to 16 stations D U B Indicate special specifications separately on a manifold specification sheet. Note 2) The number of blanking plate assemblies is also included.

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

.: Alarm output 1> Power supply voltage 24V DC and load resistance 1k (+ internal resistance 350), Load current = 24V DC / (1k + 350) = Approx. 18mA DC 4: Determination of load resistance of alarm output for intrinsic safety type of explosion protected construction specification.

Number of auto switches mounted Rod boot material Symbol Models 2 pcs. 1 pc. 70C00 Nylon tarpaulin J D-C7, C8 D-B5, B6 D-H7 D-G5, K5 110C Heat resistant tarpaulin K 15mm 10mm The maximum ambient temperature for the rod boot itself. 20mm 15mm D-B59W 20mm 10mm D-H7LF 3 Series CBG1 Rubber Bumper Type: CBG1BN With rear lock: CBG1BN Bore size Stroke H MM H GA GB Width across flats B1 2-Rc

E A F B C D Position For transporting a workpiece to a specific position Pushing For applying force to a workpiece or for measuring the size of a workpiece E A C F B D Setting completed (Download) Step 4 Step 3 Setting of operating conditions -Entering of the operating valuesAfter the operating conditions have been set, Click the [Download] button to complete the settings.

D-SMC, P-63 (M) 2nd printing September 1996. D-SMC, P-59(YG) March 1997. 29(YG) Printed in Japan.

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.