Flow Characteristics With DIN terminal block With terminal block Port size Flow characteristics 2 3 (A R) b Cv C [dm 3/(sbar)] 1 2 (P A) b Cv C [dm 3/(sbar)] 26 38 0.38 0.30 7.0 9.8 27 38 0.37 0.32 7.4 9.8 27 40 0.36 0.22 7.3 9.8 25 40 0.37 0.20 6.8 9.6 2 1 (A P) b Cv C [dm 3/(sbar)] 3 2 (R A) b Cv C [dm 3/(sbar)] 1/2 3/4 Port size Effective area (mm2) 2 3 (A R) 1 2 (P A) 235
(A cylinder with 4 bore has been added as a compact type to the existing CJ2: 6 double acting cylinder.)
U S Can be locked with a padlock in the exhaust condition. E C Padlock mounting position C D D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SUP SUP . A OUT IN A OUT IN 1 2 B 3 B EXH. EXH.
In order to prevent a malfunction or diaphragm damage caused by debris or cutting chips in the fluid, install a filter with approximately 100 mesh on the inlet side of a flow switch. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Z I SE3 Common A White Normally Open B (N.C.)
Product: Strainer ALBA90-30 ALBA90-10/-20 At the terminal of an air pressure line in which a Booster Lube is used, install a strainer (filtration rate of 5 m) upstream from a metal seal solenoid valve, which is susceptible to dust.
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.
The element can be replaced with a single touch.
Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AME650 is obtained when the max. flow line is above the point of intersection A in the graph. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.
AV AU AF AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ALF500/600 IR Port size D VEX AMR ITV IC Model Port size VBA C D A B , 1 4 3 8 1 2 , ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 80 85 90 100 100 100 238.5 246.5 295.5 319.5 338.5 344.5 44 46 48 51 59 63
Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AMG650 is obtained when the max. flow line is above the point of intersection A in the graph. HA AT Max. air flow rate (m3/min (ANR)) ID Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.
Series VVX31/32/33 Construction/Principal Parts Material Port R Port P Port A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Option Material Description No.
A A A A 1 (Station n) (Station 1) L1 L2 (Pitch) P = 10.5 4.5 (Light/surge voltage suppressor) 15.5 15.5 (Station n) (Station 1) + + (Light/surge voltage suppressor) A A 20 48.5 [55.5] 15 5 B B + + 16 1.5 One-touch fitting (A, B port) Applicable tubing O.D.: 4, 5/32" (Pitch) P = 10.5 33.1 A A 20 15 B B 1 (Pitch) P = 10.5 5 M5 x 0.8 (A, B port) 16.5 L plug connector (L) M plug connector (M)
equipped with a limit indicator on which the prescribed pressure range can be viewed at a glance.
Heater: 8 XLC Series Dimensions XLC: Air operated (b) E C Size 16, 25, 40 E C E Fn (KF flange) (a) D Auto switch (Option) Heater (Option) (c) H J B A G A (b) C E Size 50, 63, 80 E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) H J K B A G A [mm] Model A B C D E*1 Fn Fd G H J K XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27 12 40 26 44 21 XLC-
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
FGDT/F(L250) Replacement case assembly FGDT/F(L500) FGDC/E(L250) FGDC/E(L500) 25 A FGD Series Dimensions FGDA (1 element) FGDB (2 elements) 108 108 2 x Rc 2 x Rc AIR VENT M6 AIR VENT M6 OUT IN OUT IN B A FGDT FGDF B A DRAIN DRAIN G1/4 G1/4 Element removal dimension: 50 mm (mm) A B Model Element length Port size Rc 314 346 A (L250) FGDC FGDE 574 606 B (L500) 3/8, 1/2, 3/4 314 349 A (L250)
33 B A 33 B D-A3 D-G39/K39 D-A3C D-G39C/K39C G 1/2 (Applicable cable O.D. 6.8 to 9.6) Auto switch G 1/2 HW A 49 B (Applicable cable O.D. 6.8 to 9.6) Hs 49 Hs 34 56 S M C A U T O S W I T C H S M C A U T O S W I T C H A 36 B 36 Auto switch D-F5/J5 D-F5NTL D-F5W/J59W D-F5BA/F59F D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL Hs Auto switch Hs Auto switch Hs Ht 24.5 SMC SMC Ht A 30 (33) B 14 A 33 B
Set point A input on. 3. Busy output is on while actuator homes. 4. Busy output turns off, and origin return outpul turns on. 5. Set point A input otf, and point A output turns otf. 3 Load 4 work pieces. 4 Move from home to point A (800 pulses) 1. Set bank 1 input on,2 & 3 off. 2. Set point A input on. 3. Busy output is on while actuator moves. 4.
Rotate the pin 30 to the right with a wooden implement such as the grip of a wooden hammer or a resin stick without scratching.