SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2KD10-30Z-NW-M9N-A"

AD17-A AD27-A AD37-A AD47-A Spacer Y100-A Y200-A Y300-A Y400-A Y500-A Y600-A Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Check valve 5 6 AKM2000-01-A (02)-A AKM3000-(01)-A 02-A AKM4000-(02)-A 03-A Pressure switch 6 IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A IS10M-60-A T-spacer 5 6 Y110-M5-A Y210-01-A (02)-A Y310-(01)-A 02-A Y410-(02)-A 03-A Y510-(02)-A 03-A Y610

1 1 1 1 2 (a) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) Note 1) The above (a), (b), (c) indicate heater mounting positions.

In the case of 0.8MPa, when port A is a vacuum, port P can be pressurized to 0.8MPa (7kgf/cmG).

It is again necessary to connect a contact protection box in order to extend its life. Please contact SMC in this case. If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

Magnet: Built-in, Mounting: Double Clevis, Bore: 16mm, Stroke: 75mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.157 lb

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if a surge is applied repeatedly. When directly driving a load that generates surge, such as a relay or solenoid valve, use a switch with a built-in surge absorbing element. 8.

If driving a load such as a relay that generates a surge voltage, use a contact protection box. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly.

L L A A L A L A L A L L A Unit symbol RB 1412 with adjusting bolt RB 2015 with adjusting bolt RB 0806 with adjusting bolt RB 1007 with adjusting bolt RB 2015 with adjusting bolt RB 0806 with adjusting bolt RB 1412 with adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt With adjusting bolt Configuration and

All three series, VQ, SX and SY, are c o m p a c t , l i g h t w e i g h t a n d a e s t h e t i c i n a p p e a r a n c e .

, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)

Description Material Model Color Zinc die-cast AR10-A 1 Body White Aluminum die-cast AR20(K)-B to AR60(K)-B AR20K-B to AR60K-B (Regulator with Backflow Function) AR10-A Polyacetal White AR20(K)-B to AR40(K)-B 2 Bonnet A-A Aluminum die-cast AR50(K)-B/ AR60(K)-B y A Replacement Parts [AR10-A] 2 OUT 1 I N No. Description Material Part no.

Modular Type Regulator AR Series AC-A Regulator AR Series AF-A Model Port size Options AF-A AR10-A M5 x 0.8 AR-A AR-A AL-A AR20-A 1/8, 1/4 AW-A Bracket AC-B AF-A AR25-A AF-A 1/4, 3/8 Round type pressure gauge AR -A -B AR30-A AL-A Set nut (for panel mount)* AW -A -B AR40-A 1/4, 3/8, 1/2 AW AG AR40-06-A 3/4 * For AR20-A to AR40-06-A, panel fitting dimensions are different from those of the

Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z M 1.4 100 x a x mn x g 1 3 a a ME x FE x Z Dynamic moment ME Dynamic moment ME does not occur. 1 3 mn x g ME M3 ME x FE x Y mn x g ME FE FE Note) Regardless of the mounting

Magnet: None, Series: J2, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 30mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: W (Double Knuckle Joint)

The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Head Cover Port Position: 90° to axis, Pivot Bracket: Shipped with pivot bracket, Rod End Bracket: U-Shaped Knuckle Joint, Type of Mount Support: U-Shaped Clevis Type, Custom-made Specifications: None, Lock unit magnet: Without magnet, Customized specification (port positions): -, Made-to-Order (hose nipple type): -

The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Head Cover Port Position: 90° to axis, Pivot Bracket: Shipped with pivot bracket, Rod End Bracket: U-Shaped Knuckle Joint, Type of Mount Support: U-Shaped Clevis Type, Custom-made Specifications: None, Lock unit magnet: Without magnet, Customized specification (port positions): -, Made-to-Order (hose nipple type): -

Bearing Type: M (Slide bearing), Bore Size: 25mm, Port Type: TN (NPT), Stroke: 30mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Inner Diameter(φ): 20, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT, Auto Switches: M9N