SMC Corporation of America
Elite Part Number Search
Search Results "ALDU900-N14B-S2"

to reach to the Speed (Unit: mm/s2) The setting to define the pushing operation or the positioning operation.

Guide Series LG1H21 How to Order 500 LG1H21 F R 2 A1 PC S2 Photo micro switch IO connector Stroke (mm) Refer to the standard stroke.

(Unit: 1 mm/s2) XX JOG 1 to "Max ACC/DEC" of the basic parameter acceleration Defines the JOG operation deceleration. (Unit: 1 mm/s2) XX JOG 1 to "Max ACC/DEC" of the basic parameter deceleration JOG thrust *1) Defines the torque limit during JOG operation. (Unit: 1%) XX Fixed distance 0.01 to Full stroke *1) Defines the Inching distance.

Impact/Vibration resistance (m/s2) 150/50 Note) Manifold Possible Use dry air (Dew point: 20C or less). If using a lubricant, be sure to use a lubricant for low temperatures.

Do not drop, bump, or apply excessive impact (PSE530, 540: 980 m/s2, PSE560: 500 m/s2, PSE550: 300 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2. The tensile strength of the cord is PSE530: 23 N, PSE540, 550, 560: 50 N or less. Applying a greater pulling force to it can cause malfunction.

Series CQ2 Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B + Stroke S2 B + Stroke S1 B + Stroke S2 B + Stroke S1 A + Stroke (S1 + S2)

With guide l = C/H/HT Combining with another guide Note) Direct mount of load Note) Friction coefficient for combining with another guide is 0.1 or less. 1092 Model Selection Guide Tact Time Heavy load specifications (2.45 m/s2) Standard load specifications (4.90 m/s2) Medium load specifications (9.80 m/s2) Light load specifications (19.60 m/s2) 4.0 4.0 4.0 4.0 300 mm/s 300 mm/s 300 mm/s

10 to 500Hz at whichever is smaller: 1.5mm amplitude or 98m/s2 acceleration in X, Y, Z directions for 2 hrs. each Vibration resistance 490m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000Vp-p, Pulse width 1s, Rise time 1ns Weight Note 3) 410g 470g 650g 1,100g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W3

Acceleration/Deceleration: 5,000 [mm/s2] It is possible to obtain an approximate cycle time by using method 1, but if a more detailed cycle time is required, use method 2. W 200 Cycle time: 0.5 seconds Method 1: Check the cycle time graph.

8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.

Move M Speed Position Accel Decel Pushing F TriggLV Pushing Sp Moving F Area1 Area2 In pos mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 Absolute 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 Absolute 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 [ ] Need to be set [] Need to be adjusted as required. [ ] Not used.

/s2) 22 36 Work load [kg] *2 3000(mm/s2) 14 29 80 5000(mm/s2) 12 29 30 Vertical 9800(mm/s2) 8 9 Actuatr specifications Electric specifications Lock unit to 500 2300 1250 500 Max. speed *3 501 to 1000 1600 800 320 [mm/s] 1001 to 1500 900 450 180 Lead [mm] Lost motion [mm] *4 Positionimg repeatability [mm] Max. acceleration/deceleration [mm/s2] 9800 0.01 0.05 or less 50 25 10 Actuation type

Maximum acceleration: 3000mm/s2 Positioning time (sec.)

Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.

Mounting orientation Note 2) 150/30 IP67 (Based on IEC60529) Impact/Vibration resistance Note 2) (m/s2) Enclosure Coil rated voltage (DC) Allowable voltage fluctuation (V) 24, 12 V 10% of rated voltage Note 3) Standard 0.35 (With indicator light: 0.4) 0.9 (With indicator light: 0.95) High pressure type, Quick response type Power consumption (W) Standard: 0.1 Note 4) (With indicator light

Contact input/output (D-sub 25 pin) and Serial RS-485 (D-sub 9 pin) (Refer to pages 92 and 93.) 170 UL, CE marking, SEMI (S2-0703, S8-0701, F47-0200), SEMATECH (S2-93, S8-95) Note 1) It should have no condensation.

S3 U0 U1 U2 U3 S0 S1 S2 S3 U0 U1 U2 U3 F F U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 S0 S1 S2 S3 Without cable Without cable Without cable (2) (2) (2) (2) Kit Kit Kit Kit Kit Kit With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable

C2 LECSC2-T9/CC-Link Absolute encoder 200V230V S2 LECSS2-T9/SSCNET/H Absolute encoder 200V230V N2 LECSN2-T9/Without network card Absolute encoder 200V240V E2 LECSN2-T9-E/EtherCAT Absolute encoder 200V240V 92 LECSN2-T9-9/EtherNet/IP Absolute encoder 200V240V *If you select with driver, the cable is included. Please select the cable type and length.

R73C OShock resistance 300m/s2 {30.6G} (Reed switch), 3m: L EX.) R73CL 1000m/s2 {102G} (Solid state switch) 5m: Z EX.) R73CZ : N EX.)

Maximum acceleration: 3000mm/s2 Positioning time (sec.)