Cover A Case Cover A Case O L L Element O-ring Window 3) Pull cover A out of the case and remove the element. Remove dust and other debris remaining inside the case by blowing it out with air, etc.
Note 6) : For thread type: NPT only 1075 A 1021-AR-B Regulator 1021-ARK-B Regulator with Backflow Function Standard Specifications 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Pressure gauge port size 1/8 Air Preparation Equipment Pressure Control
Osincea DC2wire system autoswitch isg -4 V or less in the inlemalvoltage drop and l mAor less in the weak current, it satisfies the input soecifications of most sequence controllers. lf trouble a ses, a DC 3 wire system should be used.
Osincea DC2wire system autoswitch isg -4 V or less in the inlemalvoltage drop and l mAor less in the weak current, it satisfies the input soecifications of most sequence controllers. lf trouble a ses, a DC 3 wire system should be used.
After washing the element, make sure the base seal is properly mounted. 500 A Vertical Suction Filter FHIA Series Dimensions Differential pressure indicator 16 B (34) F OUT Removal dimension K H F OUT D E C H Differential pressure indication switch FH FH 62 HOW (65) F IN 4 x I OUT A J G (mm) A B C D E F G H I J K Model Weight (kg) FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA
Check (3). (2) A command argument Check if the command It has a failure. Correct the command description. is using a value out of description has a failure. It has no failure. Check (3). specifications. It is not repeatable.
4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (A) 4 (B) 2 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) X X X X X 1.2-72
D OUT OUT IN E 2 x A (Port size) F SMC J C H 4 x K Bracket mounting thread A C D E F G H J K Model AF30-02 to 03-X2230 AF40-02 to 04-X2230 AF40-06-X2230 AF50-06 to 10-X2230 AF60-10-X2230 57 118 Rc 1/4, 3/8 Rc 1/4, 3/8, 1/2 Rc 3/4 Rc 3/4, 1 Rc 1 M4 x 0.7 x 0.5 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 44 35 53 14 53 258 245 169 165 78 73 60 60 63 59 47 47 73 73 95 90 70 70 24 24 20 18 95 90 75 70 1056
center 3 position closed center 3 position exhaust center 3 position exhaust center 3 position pressure center 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) Note 1) Except for VQZ1000 and metal seal Component Parts No
Material Description NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR Piston seal Rod seal A Rod seal B Brake piston seal Middle cover gasket Cam gasket Cushion seal A Cushion seal B Piston gasket Cushion ring gasket A Cushion ring gasket B Valve seal A Valve seal B Gasket for valve retainer Cylinder tube gasket $1 $2 $3 $4 $5 $6 $7 $8 $9 %0 %1 %2 %3 %4 %5 CY1 MY1 Note) Contact
/8 1/4 A 12.6 9.1 5/32" L2 14.4 4.2 H Connection thread 3.5 14.7 10-32UNF 1/8 1/4 3/8 1/8 1/4 3/8 1/8 1/4 3/8 1/2 1/4 3/8 1/2 13.5 11.7 1/4" 11.4 15.9 (NPT) Applicable tube 18.6 L1 16.1 21.6 13.7 5/16" 19.1 M 21.6 20 D A 16.6 16 3/8" 35.2 21 L2 H Connection thread (with sealant) 22.7 50.2 19.6 18.5 1/2" 23.7 Reference dimensions after installation of NPT thread Note 1) D is maximum diameter
Material Description NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR Piston seal Rod seal A Rod seal B Brake piston seal Middle cover gasket Cam gasket Cushion seal A Cushion seal B Piston gasket Cushion ring gasket A Cushion ring gasket B Valve seal A Valve seal B Gasket for valve retainer Cylinder tube gasket $1 $2 $3 $4 $5 $6 $7 $8 $9 %0 %1 %2 %3 %4 %5 MGQ MGG MGC MGF MGZ CY
ZK2-OM00201 (11) Filter element (10 pcs. per set) ZK2 FE1 3 A Nominal filtration rating 3 30m (12) Check valve Note) (10 pcs. per set) ZK2 CV A Note) When mounting a check valve additionally, the workpiece may not be removed unless vacuum release pressure is applied. (13) Pressure switch for vacuum assembly ZK2-ZS E A M G G A [1] [2] [3] [4] [5] [1] Rated pressure range and function E 0 to
Size 1 2 1 2 3 1 2 1 2 A B C A B A B A B 2 2 3 3 3 4 4 5 5 2 2 2 3 3 4 4 5 5 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 SMC SMC P U Panel mount union Union SMC SMC With reducer Basic size Note) Select the fittings of the same size as the one at the valve side
Pressure cannot be applied from a 3 port valve RETURN port.
A two stage regulator is simply two regulators in series with a common body. Two stage regulations are two separate regulators in series. 3.
Install a water hammer relieving valve. 2. Use a flexible material for piping (such as a rubber hose) and an accumulator that can absorb impact pressure. 3. Keep piping as short as possible. Use the product within the specified operating pressure and temperature range. Reserve a space for maintenance.
36 132 50 41 200 74 60 230 74 60 271 86 70 22 36 110 180 544 612 873 JIS Symbol 1 4 1 2 2 Construction/Parts/Dimensions ANA1-01 to 06 Sound absorbing Case material (PFV ) End plate Hexagonal flats ANA1-06: PP How to Order Cover ANA1-10 to 20 Sound absorbing material Body Tension bolt End plate A1 03 AN Port size Symbol Connection Port size 1 8 01 1 4 3 8 1 2 3 4 02 03 04 06 10 12 14 20 (
Thread type Rc G NPT NPTF Nil F N T Stations 02 : 10 2 stations : 10 stations D side U side 1 2 3 4 5 How to Order Valves (VCA30/40) VC A 5 1 G 3 4 03 For air Thread type Rc G NPT NPTF Nil F N T Series 3 4 Class 3 Class 4 Port size (OUT) 5 N.C. for manifold Valve type Symbol 03 04 06 Class 3 Port size 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Fluid General air Dry air Nil A Orifice size Orifice
Electric signal 2 IN blue 3-2-3. Ground connection Make sure to ground the ground terminal with a ground resistance of 100 or less. The ground terminal is used as a reference electric potential for static neutralization. If the ground terminal is not grounded, the Ionizer will not be able to achieve the optimal offset voltage (ion balance). Ground terminal 3-2-4.