(2.5)] VFRA4311-04 3 8 VFRA4411-03 3 position exhaust center 1.2 1 8 PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] 1 2 VFRA4411-04 3 8 65 (3.6) [PA, B: 30.6 (1.7)] VFRA4511-03 3 position pressure center 1.2 1 8 VFRA4511-04 1 2 67 (3.7) [PA, B: 30.6 (1.7)] ( ): in case of normal position.
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Model Port size Note 2) INLET OUTLET Rated flow rate (L/min) FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 1B 1/2B 20 1B 3/4B 50 1 1/2B 1B 100 1 1/2B 1 1/4B 150 2B 1 1/2B 200 2B 2B 300 2 1/2B 2 1/2B 450 3B 3B 600 3 1/2B 3 1/2B 750 4B 4B 900 Note 2) Both flange
0 70 _ _ 4 0 17.6 _ _ 0 1 2250 _ _ 2 1 66 _ _ 4 1 16.5 _ _ 0 2 1125 _ _ 2 2 62 _ _ 4 2 15.6 _ _ 0 3 750 _ _ 2 3 59 _ _ 4 3 14.8 _ _ 0 4 562 _ _ 2 4 56 _ _ 4 4 14.1 _ _ 0 5 450 _ _ 2 5 53 _ _ 4 5 13.4 _ _ 0 6 375 _ _ 2 6 51 _ _ 4 6 12.8 _ _ 0 7 321 _ _ 2 7 48 _ _ 4 7 12.2 _ _ 0 8 281 _ _ 2 8 46 _ _ 4 8 11.7 _ _ 0 9 250 _ _ 2 9 45 _ _ 4 9 11.3 _ _ 0 A 225 _ _ 2 A 43 _ _ 4 A 10.8 _ _ 0 B 204
A)4 2(B) (A)4 2(B) Fitting, Plug Part Nos.
A b . A b . A PLCetc Axis Axis Axis No. 1 No. 2 No. 3 "b01" is displayed on axis No. 1, "Ab." is displayed on axis No. 2 and later. PC or PLCetc Controller After PC or PLCetc reset 0 1 b b . A b . A One axis is connected per reset.
(With 2 input blocks) With external pilot specification 46.5 (Pitch) 15.8 9.5 16.5 20.5 17.5 P = 16 M3 M12 11.9 9.2 17.7 25.2 30.6 3 3 4 A 4 A 4 A 4 A 4 A 3 3 3/5 E PWR 49.9 42.7 4 A 4 A 4 A 4 A 4 A E 3/5 3/5 E PWR 2 2 E 3/5 63.5 2 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 1 1 1 1 1 P P 1 BUS 0 P 1 1 P BUS 0 0 0 X PE PE x One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4, N3 6
3/5 3/5 4 A 4 A 4 A 4 A 2 B 2 B 2 B 2 B 2 B P 1 P 1 One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.
A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
A 1 () () A 2 LECSCSeries/ / *3) 1 1.5 3) 1 1 () A 3 1. 15P()-N() 2. L1L2L3(MC) (MC) 3. () () A 4 4.
A: Orange B: Green (n) (2) (1) stations (Press and turn for the locking type.)
A: Orange B: Green (n) (2) (1) stations (Press and turn for the locking type.)
A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield (3) Cable color Terminal No.
T) V 1 2 1 2 1 2 1 2 LVQ3 , LVQ4 LVQ5 , LVQ6 N M V A B U B A Z (Max.
Brown 2 A B-1 Red 1 A A-1 Cable length (L) Orange 6 B B-2 Yellow 5 B A-2 1.5m 1 Green 3 COM-A/COM B-3 3m 3 Blue 4 COM-B/ A-3 Shield 5m 5 Cable color Terminal no.
Note 4) 32 A to 50 A are 80C. 17-3-36 5 Series VXD21/22/23 Pilot Operated 2 Port Solenoid Valve For Air, Gas, Water and Oil The VX series will be revised shortly. How to Order (Normally Open) VXD21 2 VXD22 VXD23 Bracket Nil B None With bracket VC Model Thread connection sizes are available from 03 to 10.
/8 With sub-plate 1 1/2 With sub-plate 04 53-SY9000 1 (P) (EA) 5 3 (EB) 2-position double Manual override 2 (B) (A) 4 2 E: Push-turn locking lever type D: Push-turn locking slotted type Nil: Non-locking push type (EA) 5 1 (P) 3 (EB) 3-position closed center 2 (B) (A) 4 3 Note 1) (EA) 5 1 (P) 3 (EB) 3-position exhaust center 2 (B) (A) 4 4 Note 1) (EA) 5 1 (P) 3 (EB) Lead wire length 3-position
Standard stroke range (mm) Long stroke range (mm) Bore size (mm) B1 A C D E F GA GB H H1 I J K KA MM NA P S TA TB TC ZZ WA WB WH W CS1 AL 30 18 22 22 30 35 35 40 40 15.5 13 17 17 19 27 27 32 41 14 8 10 12 16 20 20 25 30 2 2 2 2 2 2 3 3 12 12 12 13 14 14 20 20 10(12) 35 5 6 6 8 11 11 13 16 26 M4 x 0.7 depth 7 5 6 8 10 14 18 18 22 26 M8 x 1.25 11 11 11 12 13 13 11 M5 x 0.8 106(114) 16 15(
To screw a bracket or a nut onto the piston rod, make sure to retract the piston rod entirely, and place a wrench over the flat portion of the rod that protrudes. 1-7-33 Series CDG1KW Auto Switch Specifications Refer to p.5.3-2 for details of the auto switch.
) (2 ) 2 1 ( (14) (1 ) 5.5) B1 A1 5 6 (17.7) (3 ) 2 1 (18) B6 A6 ( 6.3) 16 15 (11) (30.7) 66 - 15.3 [5m ] (1) (2 ) ---A B-1 2 L A A-1 1 B (B-2) 6 B (A-2) 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (3) 5 5m Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 B (B-6) 9 B (A-6) 8 3 (4) S 4 (+) B-1 5 (-) A-1 1 (+) B-3 2 A-3 (8) (1) (2 ) (B 1) (14.2) A1 2 1 (17.7) (14
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 310 A Series PF2W For Water Digital Flow Switch Dimensions: Remote Type Monitor Unit For Water PF2W3-A Panel mount adapter type Internal Circuits and Wiring Examples -0 NPN (2 outputs) Position Detection Switch Flow Sensor Pressure Control Pressure Sensor 41.8