Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
~~ , A 00) 0(0) 0 (2.5) 2(6) 4(7. 5) ~ , 40 D-AG 43.5 49 55.5 3 D-AS 1(0 1(0) 5(1.5 I O{S.5) 8(4 3t 35 42 so 57 .5 ~ Ht A 00) 00) 0(2.5 26 417 .5) D-A3 B !
[Check valve] A check valve is a safety device intended to prevent reverse flow. The AP 64 is a unique design with only one moving part in the gas stream, an O-ring. It is a springless design, free of springs and poppets. [Vacuum generator] A venturi device that creates vacuum by flowing gas through a nozzle.
Distributor Series VA, VB How to Order V A 4 6 Applicable tube O.D. 6 6 Oil Distributor Number of distribution ports (VA) (VB) VB6-6 Distribution 4 ports 6 ports 8 ports 4 ports 6 ports 10 ports 16 ports 4 6 8 4 6 10 16 Both sides exhaust One side exhaust A B VA4-6 Dimensions VAl-6 VBl-6 A B C Model # Ports Applicable tubing 4 6 10 16 36.5 60 88 130 VA4-6 VA6-6 VA10-6 VA16-6 Model # Ports
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
The dual type speed controller is especially suitable for cylinders with a small bore size. Elbow/Universal Type Air Flow/Effective Area Model AS121FM-M5 AS131FM-M5 AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 RE A B 3.2, 4, 6 3.2, 4 6, 8 4 6 8, 10 Metric size Tubing O.D.
The dual type speed controller is especially suitable for cylinders with a small bore size. Elbow/Universal Type Air Flow/Effective Area Model AS121FM-M5 AS131FM-M5 AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 RE A B 3.2, 4, 6 3.2, 4 6, 8 4 6 8, 10 Metric size Tubing O.D.
L1 L2 20 27.2 13 T T A A Width across flats H Width across flats 22 H Width across flats A T Connection male threads T Connection male threads Effective area mm Min. bore Weight g Model Effective area mm Min. bore Weight g Model A L L 41.5 R 1/8 30 R 1/8 81 18 45.5 34 19.0 6 6 22.6 KK13P-01M KK13S-01M 14 42.5 R 1/4 31 R 1/4 86 22 24.1 7 -02M -02M 48.5 37 42.1 R 3/8 30.6 R 3/8 89 7.5 35.3
: SYJA5240-01 2 x 4.3 (For mounting) 44 2 x M5 x 0.8 (Pilot port) VGA 37.5 4 1 2 x M5 x 0.8 (Pilot port) 11 B A 5 VPA 1 A B 1 10 M5 x 0.8 (A, B port) 2 x 2.6 (For manifold mounting) 24 A B VPA3 19 1 P R Manual override 54 2 42 47 54 Manual override 23 20 15 3 11 2 x 2.6 (For mounting) 11.5 45 2 x 1.3 (Breathing port) 33.5 M5 x 0.8 (P , R1, R2 port) 21.5 6 6 P R1 17 17 15 8.5 R2 45.5 1/8 (
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" 38 (1.33) 7 (0.25) Flow rate l/min (ANR) (CFM) 12 (0.42) Controlled flow 0.6 (0.03) 0.2 (0.01) 0.1 (0.006) Effective area
It may result in a breakdown of membrane module, case and mounting screws or insufficient sealing. (Verify the tightening torque range in the instruction manual.) 6. Installing a pressure gauge A pressure gauge should be installed on the inlet and outlet sides of the membrane air dryer (unit) for the maintenance and inspection purposes. Maintenance Warning 1.
This acceleration process can be achieved smoothly (as a SIN function) by using a cushion spear on which a Ushaped groove is machined. 6. Reset 3. Acceleration Actuating air passes from cylinder port on rod side and enters the left chamber of the cylinder from space between cushion seal and U-shaped groove on the outer surface of cushion spear.
F(mm) Port B min. port size Weight (g) L1 L2 L3 L4 L5 L6 P Q1 Q2 M KM12-04-02-6 6 17 89 110 99 125 108 139 40 67 75 84 96 100 117 1 4 4 10 18 29.5 19.5 29 10.6 16 6 12 KM12-04-02-10 10 KM12-06-02-6 6 KM12-06-02-10 10 KM12-08-03-6 6 KM12-08-03-10 10 61.5 47 1 4 6 17 10 19.5 31.5 21.5 31 13 17 7.5 13.5 73 55 3 8 8 19 11.5 22.5 35.5 24 34.5 15.5 18.5 9 14.7 86 63 Series KM One-touch Fittings
When point input A is turned ON, the actuator begins to return to the home position. 4. BUSY output is turned ON during home position return. 5. BUSY output is turned OFF when the actuator reaches the home position, and home position return output turns ON. 6. Turn OFF point input A. 6. When point inputs A to D are turned OFF, point outputs A to D turn OFF.
When point input A is turned ON, the actuator begins to return to the home position. 4. BUSY output is turned ON during home position return. 5. BUSY output is turned OFF when the actuator reaches the home position, and home position return output turns ON. 6. Turn OFF point input A. 6. When point inputs A to D are turned OFF, point outputs A to D turn OFF.
10 14.5 4.5 U40 40 43 7 18 13.7 18.5 6.5 U50 50 53 7 18 14.7 19.5 7.5 Model Nom.size D10 A 10 ZP10Dl B 12 C 4 D 13 E 10.7 F 15 Y 6 Put in the symbol for material at the end of model no.
(A) 2 1 (P) 3 (R) Rubber seal type VQZ200 300 / Metal seal type 3 2 1 3 2 1 N.C. N.C. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) 3 2 1 3 2 1 N.O. (A) 2 N.O. (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Parts list No.
When very clean air is required, install a separator as mentioned above on the downstream side, or instead of a regulator, use the order made specification (refer to page 35) fitted with a micro mist separator regulator (series AWD). 3.
.) * Special Order XS With surge voltage suppressor x Speciallor grommet type G only. lZ oplion N/A lor grommettype G. a Electrical entrv Volta9e 5]24voc 6 12VDC x9 Otherc Note 1) Indicate in parentheses at end of part no. Ex. (AC24V).