Unrestricted 300/50 m/s2 Manual override Lubrication Mounting orientation Impact/Vibration resistance Enclosure (2) Dustproof Note1) Based on dynamic performance test, JIS B 8419: 2010.
0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
C 400 300 200 10 20 30 100 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-3 Heating capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 600 Heating capacity W 500 Radiating water flow rate L/min 400 300 200 1 3 5 100 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.
NPN open collector, single output Analog, no output, 3 turn setting 14 NPN open collector, single output Analog, no output, 200 degree setting 15 Electrical entry NPN open collector, double output Analog, no output, 3 turn setting 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 16 G H L LN LO M MN MO Lead wire length 300 mm Lead wire length 600 mm With lead wires (Length 300 mm) Without lead wires
For details, refer to the optional accessory (page 11). 6 HEF Series Cooling Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 600 600 500 500 Cooling capacity [W] Cooling capacity [W] Ambient temperature 25C 400 400 Ambient temperature 25C 300 300 200 200 Ambient temperature 35C Ambient temperature
11 13 13 8.5 9.5 9.5 11 14 5 8.5 9 10 10 6 6 6.5 8.5 11.5 Since this is a guideline including hysteresis, not meant to be guaranteed.
55 41 63 XLA-50 70 170 79 2 11 75 52 68 XLA-63 88 196 100 3 11 87 95 70 69 XLA-80 90 235 117 3 11 114 110 83 96 XLA-100 108 300 154 3 11 134 130 102 131 XLA-160 138 315 200 3 11 190 180 153 112 10 XL*-OMI0009-E 5.
55 41 63 XLA-50 70 170 79 2 11 75 52 68 XLA-63 88 196 100 3 11 87 95 70 69 XLA-80 90 235 117 3 11 114 110 83 96 XLA-100 108 300 154 3 11 134 130 102 131 XLA-160 138 315 200 3 11 190 180 153 112 9 XL*-OML0013-B 5.
300 0.6MPa 0.6MPa 400 400 Holding force (N) Holding force (N) Holding force (N) Holding force (N) 250 250 0.5MPa 0.5MPa 0.5MPa 0.5MPa 0.4MPa 0.4MPa 200 200 300 300 0.4MPa 0.4MPa 0.3MPa 150 150 0.3MPa 0.3MPa 200 200 0.3MPa 100 100 0.2MPa 0.2MPa 0.2MPa 0.2MPa 100 100 50 50 0.1MPa 0.1MPa 0.1MPa 0.1MPa 50 100 150 200 50 100 150 200 0 0 40 80 120 160 200 40 80 120 160 200 0 0 Holding point R
VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.
55 41 63 XLF-50 70 170 79 2 11 75 52 68 XLF-63 88 196 100 3 11 87 95 70 69 XLF-80 90 235 117 3 11 114 110 83 96 XLF-100 108 300 154 3 11 134 130 102 131 XLF-160 138 315 200 3 11 190 180 153 112 9 XL*-OMJ0003-D 5.
Unrestricted 300/50 m/s2 SYJ Manual override Lubrication Mounting orientation Shock/Vibration resistance Enclosure VK (2) Dustproof VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Note 1) Based on dynamic performance test, JIS B 8374-1981.
Applying an excessive impact (more than 300 m/s2) may damage the product and cause malfunction. (2) Observe the proper tightening torque for mounting. If the screws are tightened in excessive of the specified torque range (0.2 to 0.4 Nm), it may damage the cylinder/actuator, mounting screws, mounting brackets, and sensor etc.
(Values at the initial period) Shock/Vibration resistance (m/s2) (3) For vacuum/ low pressure For general Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Pilot pressure (MPa) Solenoid Specifications Grommet (G), Conduit terminal (T) DIN terminal (D) Conduit terminal
Ground 4-7-11 12 Series VT317 How to Use DIN Terminal 1.
D-Y7 W (V) 5 6 A B D-Y 9 Red light at ON Green light at ON Red light at ON Green light at ON MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 4 6 15 5 11 4 5 11 4 9 2 4 9 3 7 2 3 6 2 5 2 3 5 2 4 2.8-24
(for Junction Common) Plug connector lead wires have a standard length of 300 mm, however, the following lengths are also available. Caution Single solenoid SJ3000-46-SC-l Double solenoid, 3 position type, 4 position type SJ3000-46-DC-l Connector Assembly Part No.
Circuit example/Built-in solenoid valve Ball valve Regulator FLUID OUT AIR EXH Filter AIR SUP FLUID IN Air supply Process pump PB1011 Transfer fluid 17-5-166 27 Series PB Process Pump: Built-in Solenoid Valve Type/ Air Operated Type (External Switching Type) Dimensions PB1000 FLUID OUT Rc 1/8 VC 11 OUT VDW 11 VQ 84 72 VX2 Mount with this surface (out port side) on top 7.5 41 60 45 VX Courtesy
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
M3 3B = M3E/M3E max = 1.8/10 = 0.18 L2 M3E m x g FE From above, n = 1 + 2a + 2b + 3A + 3B = 0.25 + 0.105 + 0.084 + 0.225 + 0.18 = 0.844 From n = 0.844 1, it is applicable. 8-16-10 10 MX MTS MY CY MG CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless