The CK1 series is a clamp cylinder available in two styles of clevis widths *. It is a non-lube, compact, lightweight cylinder with a built-in speed controller. Gaiters are unnecessary because a heavy-duty coil scraper is provided as a countermeasure against spatters. The CK1 is available in 3 bore sizes with stroke lengths up to 150mm. Options include rod attachments and auto-switch capabilities.Two
Part Number Description: GASKET (ZCUK016-01-70225) Product Line: A Product Line Description: ACTUATOR Family Code: 518 Family Description: ZCU COMPACT CYLINDER Class Code: G1 Part Code: 2 Reference Code: J This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, GASKET (ZCUK016-01-70225), ACTUATOR
With abrasion resistant packings and replaceable nose seals, the C85 offers exceptional service life.Double acting, single rod, crimped cylinder, Conforms to ISO 6432 and CETOP RP52P, Bore sizes *: 8, 10, 12, 16, 20, 25, Standard strokes up to 300mm, Auto switch capable, CYL, ISO, DBL ACTING, ACTUATOR, C85 ROUND BODY CYLINDER, FD, 12MM C85 DOUBLE-ACTING, 0.33686 lb
SMC's series AW, is a combination filter/regulator, minimizing space and piping by integrating 2 units into one. The element and bowl on the AW series is now one-piece, making element replacement easier. Bowls on size 30 and 40 are covered with a transparent bowl guard, completely protecting them from the environment, and making the inside visible from 360 degrees. This series is part
HOSE ADAPTER NW25 base x hose nozzle 7/16"
PRODUCTION ASSY, 4/5 PORT SOLENOID VALVE, VVD, 10.00000 lb
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and
Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa
Single acting single rod, spring return or spring extend , Bore sizes *: 3/4, 7/8, 1 1/16, , 1 1/4, 1 1/2 , Maximum stroke: up to 6in. as standard , Available with auto switches, 1 1/16" NCM SGL-ACT AUTO-SW, ACTUATOR, NCM ROUND BODY CYLINDER, JT, 1 1/16" NCM SGL-ACT AUTO-SW, 0.39021 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, 3.08647 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DUST SEAL, ACTUATOR, CKZN SLIM LINE CLAMP CYLINDER, R1, 80MM CKZN SLIM LINE CLAMP CYL, .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, 3-POSITION, ACTUATOR, RZQ 3-POSITION CYLINDER, NC, 50MM RZQ OTHERS (COMBO), .00000 lb
Projection area, weight, and overall length has been reduced when compared to the CH2 series; Applicable bore sizes: 32mm, 40mm, 50mm, 63mm, 80mm, 100mm; Nominal pressure: 16 MPa; Available in 25mm to 1000mm strokes depending on bore size selection; Auto switch capable
FC3W is a flow controller for water between 0-50°C. A motor driven adjustable flow valve works together with feedback from a Karman vortex flow sensor to establish a flow rate corresponding to an analog input signal. When a single water supply source is divided into multiple lines, the flow rate between lines can be inconsistent. FC3W controllers can adjust flow on each line to a constant
Projection area, weight, and overall length has been reduced when compared to the CH2 series; Applicable bore sizes: 32mm, 40mm, 50mm, 63mm, 80mm, 100mm; Nominal pressure: 16 MPa; Available in 25mm to 1000mm strokes depending on bore size selection; Auto switch capable
. -7No.EX-OMV0023-A
Model Indication and How to Order EX260-SPL 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) / source 3 M12 connector, 16 outputs, PNP (negative common) / source Fieldbus PL POWERLINK -8No.EX-OMV0023-A
Summary of Product elements
) Note 16) Note 16) ON Power supply +24 VDC OFF ON Ion generation stop External input signal Input OFF ON Controller button / / S button OFF ON Maintenance detection signal (Normally OFF) Output OFF ON Error signal (Normally ON) OFF ON CH display Selected CH to display 1Hz 1Hz 1Hz 1Hz 1Hz 1Hz OFF CH display CH which display is not selected CH display High voltage power supply module
Reassemble the parts such as valve and cover in the reverse order of the removal "1" to "3". -16- Revision history Edition B Ionizer changed.