SMC Corporation of America
Elite Part Number Search
Search Results "AC40B-N06C-V-Z-D"

(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.

(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.

type PF3W30D PF3W30F Max. 28 V, 80 mA Internal voltage drop 1 V or less C: Analogue output 1 to 5 V Max. 80 mA Internal voltage drop 1.5 V or less E: Analogue output 1 to 5 V Output impedance 1 k Output impedance 1 k D: Analogue output 4 to 20 mA F: Analogue output 4 to 20 mA Max. load impedance Max. load impedance When power supply is 12 V: 300 When power supply is 24 V: 600 When power

Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" AS1002FS V V V V V V AS2002FS V V V V AS2052FS V V V V AS3002FS V V V V V V V AS4002FS V V V V 1 Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the Web Catalog for details.)

Fluids VCC Series Union Nut Socket 1209 1008 1075 VCC-G-D-1 (Applicable fitting VCK ) VCC-G-D-1 2 13 Width across flats: 19 25.5 14 60 VCC-G-D-2 (Applicable fitting VCK ) 0806 0604 9 Width across flats: 17 20.5 14 50 For extending the socket VCC-G-D-1 VCC-G-D-1 VNA 113 VNB SGC SGH VCC-G-D-1 VNC VNH VCC-G-D-2 VND 97 VCC VCC TQ 655 VCC Series Disassembly/Assembly/ Maintenance Procedure Cleaning

Note 2) Value on option "V" (Non-leak, Vacuum).

ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.

Green OFF COM D has no received data. COM D Green ON COM D is receiving data. NOTE When connecting manifold valve only without connecting Input unit manifold, LEDs of COM A D do not light.

A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

, Tool required L plug connector Locking type (Manual) Single Locking type Closed center Double Exhaust center Pressure center Grommet Plug-in 12 V 24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz 4/2 5/3 (A/B R1/R2) 3 position Closed center Double Single Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal VQ130 0.73

Designation Content 1 SV24 V (PWR(V)) +24 V for valves 2 SV0 V (PWR(V)) 0 V for valves 3 SI24 V (PWR) +24 V for logic/sensors 4 SI0 V (PWR) 0 V for logic/sensors Fig. 2-4 Pin allocation of M12 4 pin plug A-coded connector Power-supply line for valves and power-supply line for logic/sensors operation are isolated. Be sure to supply power respectively.

AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 Cuts air consumption by operating the return stroke at a reduced pressure.

(A/D ) ( ) 6 2030 20 80 mA (Er1,2) () ( (Er4,6,7,8) ) DC1224 V DC1224 V Er1,2) Er4,6,7,8) 7 (HHH) "HHH" "LLL" Er3) (LLL) (Er3) 7F.S. -27No.PS-OMG0001CN-H No. DC1224 V DC1224 V 8 DC(+) DC(-) DC1224 V DC1224 V DC(+) 9 DC(-) / / 10 ( ) 11 / 5m / 12 2030 20 -28No.PS-OMG0001CN-H No.

OUT() DC(-) DC(+) PSE57--28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -13No.PS-OMS0004CN-D (A/D ) () 20 2030 -14No.PS-OMS0004CN-D PSE570 PSE573 PSE574 01MPa -100100 kPa 0500 kPa 3.0MPa 600 kPa 1.5MPa oC) oC) (25 ) 2F.S.(050 3F.S.(050 oC) oC) 3F.S.(-1060 4F.S.(-1060 PSE57PSE57--28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 oC) 1.0F.S. 0.5F.S. oC)

V 4 Q D 1 5 Clean series Manifold type 2 Body ported 5 Base mounted Valve stations 02 2 stations 20 20 stations (Maximum) Port size M5 M5 x 0.8 C4 4 cassette Note) 1(P), 3(R) ports: Rc1/8.

S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type VQZ VZ VS For AC (50/60Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] VFN Light/Surge voltage suppressor Electrical entry Nil R U Z For DC, AC Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor 24 V, 12 V, 6 V, 5 V, 3 VDC/100

IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 134 Thermo-chiller Inverter Type HRSH090 Series Circulating Fluid Temperature

as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 97 Thermo-chiller Standard Type HRS100/150 Series

Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: without Attachment, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter Drain Port: w/Drain Cock, Exhaust Mechanism