Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: T (w/o Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: K (Operation Manual,
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: T (w/o Operation Manual, Calibration Certificate
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Type: S3 (200W Output, Incremental Encoder), Lead: A (LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 300mm, Motor Option: w/o Lock, Vacuum Port: R (Right), Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 2 (2m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input)
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Type: S2 (100W Output, Incremental Encoder), Lead: A (LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 400mm, Motor Option: B (w/Lock), Vacuum Port: D (Both Left and Right), Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse