FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, HX, TR 8MM, 3.96834 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU0805851--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, LX, TR 12MM, 13.74109 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU12081281--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, JX, TR 10MM, 5.78100 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU1065106.51--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, JX, TR 10MM, 5.56667 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU1065106.51--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, JX, TR 10MM, 28.66009 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU1065106.51--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, HX, TR 8MM, 4.47284 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU0805851--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, FX, TR 6MM, 2.71109 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU0604641--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, FX, TR 6MM, 2.84151 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU0604641--
FR three-layer polyurethane tubing , Flame resistant , Equivalent to UL-94 standard V-0 , 20m and 100m reels available , Several color options available , RoHS compliant, TUBING, FLAME RESISTANT, CONNECTORS, TR FLAME RESIST TUBING, FX, TR 6MM, 2.64554 lb, ModelInner tube O.D. (mm)Inner tube I.D. (mm)Outer layer thickness (mm)--TRTU0604641--
Developed to be combined with our extensive line of fittings, the addition of the TLM tube provides customers with a complete solution for their piping equipment needs., FLUOROPOLYMER,TUBING NAT 100M, CONNECTORS, TIL/TL FLUOROPOLYMER TUBING, LX, TIL/TL 12MM FLUORINE TUBING, 2.93948 lb
Developed to be combined with our extensive line of fittings, the addition of the TLM tube provides customers with a complete solution for their piping equipment needs., FLUOROPOLYMER, TUBING NAT 100M, TUBING, FLUORO. TL/TIL, TD/TID, TH/TIH, 18.13 lb
Developed to be combined with our extensive line of fittings, the addition of the TLM tube provides customers with a complete solution for their piping equipment needs., FLUOROPOLYMER,TUBING NAT 100M, TUBING, FLUORO. TL/TIL, TD/TID, TH/TIH, 7.56 lb
your piping equipment needs., FLUOROPOLYMER,TUBING NAT 100M, CONNECTORS, TIL/TL FLUOROPOLYMER TUBING, MX, TIL/TL 1/2" FLUORINE TUBING, 26.89639 lb
Developed to be combined with our extensive line of fittings, the addition of the TLM tube provides customers with a complete solution for their piping equipment needs., FLUOROPOLYMER, TUBING NAT 100M, TUBING, FLUORO. TL/TIL, TD/TID, TH/TIH, 7.6 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, HYDRAULIC, 10MPA, OTHERS, CH HYDRAULIC CYLINDER, RE, 80MM CH DBL-ACT AUTO-SW, 11.93931 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 3.52739 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [lb] Note 2)Pushing force [lbf] Note 3) 4)Speed [mm/s]Max. acceleration/deceleration[mm/s2]Pushing
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting