EMG (2)M 24V (1)C 24V 0V(4) DC24V 0V OFF 28 - 32 DC24V M24V EMG () 0V DC24V Ry (1 ) (3)EMG LK RLS6 Ry (1)C 24V (2)M 24V 0V4 DC24V 0V (2 ) (3)EMG LK RLS6 Ry (1)C 24V (2)M 24V 0V4 DC24V 0V (3 ) (3)EMG LK RLS6 Ry (1)C 24V (2)M 24V 0V4 DC24V 0V 1DC24V M24V EMG 2M24V(SETUP ON) (M24V) 3M24VLK RLS 29 - 7DeviceNet DeviceNet JXCD1 DeviceNet 1 DeviceNet AWG24120.2mm 22.5mm 2 M3

INNER VALVE(B) LOCK NUT (261020) INNER VALVE (A) (M3) (26102) 251 INNER VALVE Assy (26100-6) -8- 7.Countermeasures for failure ! Warning Avoid use when failure is not solved. Phenomenon Cause Countermeasures Dust attach supply port or exaust port Disassemble and clean. (If flawed, replace the part.)

Proper tightening torque The tightening torque of the M3 mounting screw must be 0.5 Nm (5.1 kgfcm). < D-S79, D-S7P, D-T79, D-T79C > 1. Auto switch mounting Loosen the cross recessed round head screw (2), and insert the arm of the auto switch. 2.

Model Thread size Tightening torque SX3000 M2 0.17 Nm SX5000 M3 0.8 Nm SX7000 M4 1.4 Nm 11 SX3000-OMM0002-B -12-SX3000-OMM0002-B -13SX3000-OMM0002-B TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

Connection of fittings When screwing fittings into valves, tighten as follows. (1) Follow the procedures below when installing an SMC fitting, etc. 1) M3 After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn.

Cross recessed round head screw for mounting the bottom bracket Square nut Bottom bracket Applicable torque IRV10(A):M3 0.320.03Nm IRV20(A):M4 0.760.05Nm 8 - Caution Handling (1) Reduce the set pressure to zero(atmospheric pressure) for removing the plug when additionally mount the pressure gauge and pressure switch. 1.For customers purchasing regulator with a pressure gauge or pressure switch

crimp branch connector ( ) into branch cable (EX510-FC ) 1 Branch connector on the SI unit side and connected them to GW unit. 2 Load mounting connector Connecting output equipment such as solenoid valve. 3 Power supply LED Lights up: Power ON (Normal) Goes off: Power OFF 4 Communication LED Lights up: Data received Goes off: No data received 5 Mounting hole Used to mount the unit with two M3

Tighten the FG terminal (M3 round head combination screw) firmly with a tightening torque of 0.3 Nm. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. A. Dual power supplies B. Single power supply Figure 3 Figure 4 : Communication connector FG and FG terminal are connected inside the SI unit.

For HAA71522 series Power cord Terminal Insulated ring terminal Customer connection side Terminal screw : M3 Connector width :6.5mm Suitable wire :0.75mm2 For HAA37 series Customer connection side Terminal screw : M3.5 Connector width :8.3mm Suitable wire :0.75mm2 HAA Series 12 9 1)Terminal Assembly (Symbol: T) ATX-OM-F004E Air-Cooled Aftercooler 9.

Without flow adjustment valve (using ZS-33-M) With flow adjustment valve (using ZS-33-MS) Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. Refer to the dimension drawing of the bracket (page 37) for mounting hole dimensions.

Actuator mounting A Model Bolt size Maximum tightening torque [Nm] Amm) mm LEKFS16 M3 0.63 3.5 23.5 LEKFS25 M4 1.5 4.5 24 LEKFS32 M5 3.0 5.5 30 LEKFS40 M6 5.2 6.6 31 4. When mounting the actuator, leave a gap of 40mm or more to allow for bending of the actuator cable. 20 - 3.4 Precaution on maintenance Warning 1.

Mount with the set screws M3 size (2 pcs.) supplied for direct installation. The required tightening torque of the mounting screws is 0.5 to 0.7 Nm. Mounting with panel mount adapter Panel mount adapter + Front protective cover (Model: ZS-39-D) -15No.PS-OMM0005-J Removal and mounting on DIN rail It is necessary to prepare a DIN rail adapter for the mounting on the DIN rail.

Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm. -14No.PS-OMM0003-J Mounting with panel mount adapter -15No.PS-OMM0003-J Piping Connection using screw type piping Connect suitable piping to the port.

Every air cylinder intended for use or mounting in Japan, with the gauge pressure of 0.2 MPa or more and the cylinder internal capacity of 0.04 m3 and more, or with the cylinder inside diameter of 200 mm dia. or more and the stroke of more than 998 mm falls within the scope of the second class pressure vessel regulations.

Bore size Hexagon socket head Appropriate tightening (mm) cap screw (mm) torque (Nm) 6, 10 M3 1.0810% 16 M4 2.4510% Do not use compressed air containing a lot of condensate, which 20, 25 M5 5.1010% can cause the operating failure of the product and other pneumatic 32 M6 8.0410% equipment. Ensure that fluid and ambient temperature are within the specified range.

Connection of fittings When screwing fittings into valves, tighten as follows. (1) Follow the procedures below when installing an SMC fitting, etc. 1) M3 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn. As a reference value, tightening torque is 0.4 to 0.5Nm.

Connection of fittings When screwing fittings into valves, tighten as follows. (1) Follow the procedures below when installing an SMC fitting, etc. 1) M3 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn.

(Applicable bolt size is M3) These grooves can be used for firmly fixing the tying bands of lead wires of the auto switch, etc., and also terminal boards, etc., to the main body of the cylinder. When the terminal block is fixed on a cylinder directly. 6 12. Piping 12-1. Attention in piping 1) Use clean air.

Mounting dimension on side face Size Bolt Tap depth Size Bolt 05 M4X0.7 5 Body tap Body through hole 1 M5X0.8 6 05 M4X0.7 M3 1 M5X0.8 M4 Piping Fig. (4) and Table (8) show port position and size. A port A port B port B port Side port Front port Fig.4 Port position 24 - Table 8. Port size .

50 63,CF114 80 Actuating type Normally closed (Pressurize to open , spring seal) Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (High temperature type:5 to 150) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pa m3