Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 46, Table Material: [Aluminum] Aluminum, Guide: [Rolling Guide] Linear guide type, Table Size Width W(mm): 32, Table Size Height H(mm): 23, Table Parallelism(µm): 25, Table Surface Treatment: Electroless Nickel Plating, Environment: General Purpose, Maximum Load(kg): 1, Types: Symmetrical shape, Port Screw Type: M screw,
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 46 DEGREE ELBOW, CONNECTORS, KQ2 FITTING, CX, KQ2 4MM, .02388 lb
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 46 lb
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, MALE CONNECTOR, ONE-TOUCH FITTING, 945, 46 lb
46?0.11?0.1?------??--Translucent (color of material)Please refer to the applicable fluid in page 41.1 MPa6.9 MPa20260CSuper PFA
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 949, 46 lb
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, BR UNI MALE ELBOW, ONE-TOUCH FITTING, 957, 46 lb
Consider the kinetic energy applied when stopping and the lateral load applied during stopping.
The kinetic energy is determined by the mass of the transported object and the transfer speed. During a stop, the load continues to act due to the relationship between the transport load (weight x g) and the friction from the conveyor, which acts as a lateral load on the cylinder.
Refer
Order an MGP series cylinder with the special order part number suffix “-X144.”
For the symmetrical port position type, the side piping port positions and the top piping port positions are changed.
Repeated return to origin operations can be performed. See below for how to check the completion of return to origin operations when performing them repeatedly.
How to check return to origin completion: The completion of the return to origin operation is confirmed by a SETON signal.
However, the SETON signal is turned ON when the first return to origin operation is completed,
When mounting to the ceiling, selection is the same as for other methods of horizontal mounting.
However, note that if the stroke is too long, the seal band may bend.
The purge air flow rate cannot be adjusted because it is performed with an internal fixed orifice.
If the valve is continuously energized for a long period of time, the temperature rise caused by the heat generated by the coil assembly may degrade the performance of the valve and adversely affect the service life of the product or the peripheral equipment.
In addition, even for low power consumption types, it is recommended that the valve be switched ON/OFF at least once every 30 days
Yes, SMC offers an elbow, universal, and in-line type speed controller with an indicator. All 3 types have a stainless steel specification. In addition, the list of applicable special order options is being gradually expanded. For further details on clean, throttle valve (restrictor?), and grease-free specifications, refer to the catalog.
CHILLER, RACK MOUNT, REFRIGERATION TYPE. Rack Mount Refrigeration Chiller. 40.00000 lb. O72.
Dual Channel Chiller for Lasers, HRS090 AND LARGER CAPACITIES, O88, 330 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 29 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 74.00000 lb