T dimension) 0 1 5 None Differential pressure indicator Differential pressure indication switch Note) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)

2 x 3.5 Mounting hole Piping port M5 x 0.8 depth 5 13 13 01: R 1/8 T1: NPTF 1/8 01: R 1/8 T1: NPTF 1/8 IS ISG ZSM 785

exhaust center 3 position pressure center 2 3 4 5 5 24VDC Rated voltage 2 1 Station U side D side Pilot type 24VDC -COM SMC Nil R Internal pilot External pilot SS5X3-45GD-05U-C6 .1 set (manifold part number) SX3140-5LOZ ... 3 sets (single solenoid part number) SX3240-5LOZ ... 2 sets (double solenoid part number) The "" symbol indicates mounting.

(mm) 4 6 8 10 12 3.18 4.76 6.35 9.53 12.7 2.5 4 5 6.5 8 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst Pressure Characteristics Curve Yellow (Y) Green (G) Clear (C) Orange (YR) Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Specifications Fluid Air, Water Max. operating pressure 0.8MPa at 20C Refer to pressure characteristics curve.

FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

1 V 2815 V 1 k 29420 mA 12 V300 24 V600 -40No.PF-OMO0007CN PF2A7--28--X560 PF2A7--68--X560 PF2A7--29--X560 PF2A7--69--X560 (15 V) (420 mA) 12 V 300 24 V 600 1 k 5F.S. 1 s A B 1 V 5 V 4 mA 20 mA 1 NL/min 10 NL/min PF2A710 3.5 CFM10 -2 35.0 CFM10 -2 5 NL/min 50 NL/min PF2A750 18 CFM10 -2 176 CFM10 -2 10 NL/min 100 NL/min PF2A711 3.5 CFM10 -1 35.5 CFM10 -1 20 NL/min 200 NL/min PF2A721

(mm) M Effective area (mm 2) Weight (g) A L2 L1 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 DL04-01 15 3.5 23 DL04-02 17 19 4 10 23.5 19.6 10 30 DL06-01 25 17 Applicable tubing 19.6 10 23.5 DL06-02 16 19 31 14 6 9 12 DL06-03 22 53 26.5 24.5 21.6 22.6 24.5 25.8 24.5 29.4 29.6 30.3 29.4 91 Reference dimensions after R thread installation.

(SI unit side) Valve manifold Output No. 1 3 5 7 9 17 29 31 Solenoid on side B Accessories Bit No. 1 3 5 7 1 1 5 7 Replacement of the SI unit Remove the M3 hexagon screw from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.

Note 4) Assembly of a bracket and set nuts Standard Specifications AWM20 AWD20 AWM30 AWD30 AWM40 AWD40 Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.85 MPa Pressure gauge port size Note 1) 1/8 1/4 Ambient and fluid temperature Note 2) 5 to 60C (with no freezing) AWM20 to AWM40 0.3 m (95% filtered

Input "n+1" 2 Power supply (0 V) 3 1 2 1 3 Input No.1 1 5 3 Power supply (0 V) 4 4 4 3 Input 4 Input connector "1" Input No.0 1 4 Input "n" 3 1 2 Input connector "2" 4 Input No.3 5 Ground 4 5 4 3 Caution 3 Input No.2 3 1 After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.

locations) Ambient and fluid temperature Note 3) 5 to 60C (No freezing) Weight (kg) Note 4) 0.13 0.23 0.47 Note 1) When there is no flow rate on the outlet.

end plate assy u-side, VV5Q* MANIFOLD VQ 4/5 PORT*** $29.05 + Add to Quote Add To Cart Add to Cart SMC VVQ2000-2A-1-S end plate assy u side, VV5Q* MANIFOLD VQ 4/5 PORT*** $38.64

(The tightening torque for the M3 screw should be 0.8 to 1Nm {8.2 to 10.2kgfcm}.) 5. Perform changes of the detection position under the same conditions as step 3. 24 Series RSDG Auto Switch Hysteresis Contact Protection Boxes/CD-P1 1, CD-P12 D-C7/C8, D-C73C/C80C The above auto switches do not have internal contact protection circuits. 1.

AMK20 AMK30 AMK40 Port size 1/8, 1/4 1/4, 3/8 1/43/8, 1/2 Fluid Air Ambient and o fluid temperature -5 to 60 oC (No freezing) Proof pressure 1. 5MPa Max. operating pressure 1. 0MPa Min. operating pressure 0.05MPa Outlet side oil concentration Note1) Max. 0.003mg/m3(0.0025ppm) Compressed air purity class Note 2) ISO8573-1: 2010[1: 4: 1] Note 3) Max. flow capacity Note 4) 300 L/min (ANR) 750L

Nil 6 5, 10 S 1 pc. 8 10, 20 n n pcs. In the case of MXP6-5, with 2 auto switches are available for DM9 type and D-M9V type only.

Note 12) 3/4", 1-1/16" and 1-1/2" only. 1 Series NCM Auto Switch Specifications Applicable Auto Switches Lead wire length (m) Load voltage Indicator light Yes Wiring (Output) Type Special function Electrical entry Applicable load Pre-wired connector Auto switch model 3 (L) 0.5 (Nil) 5 (Z) 1 (M) None (N) AC DC M9N M9P M9B H7C M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5 V, 12 V Grommet