SMC Corporation of America
Elite Part Number Search
Search Results "LECP1P5-LEHF40K2-80"

N.O. 5.5 5.7 2 VNC0 VNC02 1 4 10.2 10.4 50 12 (P1) 10 (P2) VNC814-65F VNC811-65F VNC914-80F VNC911-80F 15.7 Air operated 65 1 2 1 2 21.2 80 Note) The companion flange is JIS B 2210 10K (standard) or its equivalent.

VQC5000 Bore size MB, CA1 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm CS1 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Average speed [mm/s] 50 63 80 100 125 140 160 180 200 250 1100 Vertically upward Horizontal 1000 900 800 700 600 500 400 300 200 100 0 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open

Metric size 2 3.2 3.2 4 4 6 6 8 10 12 Inch size 1/8" 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" 3/8" 0.8 Fluid Air, Nitrogen 0.6 Operating pressure 100 kPa to 1.0 MPa (at 20C) Flow rate (Positive pressure) [L/min] *1 15 45 50 80 100 200 250 450 550 650 0.4 Flow rate (Vacuum pressure) [L/min] 2 5 7 10 10 20 30 70 80 100 0.2 Proof pressure [MPa] 1.5 (at 20C) Operating and ambient temperature range

] Supply pressure [MPa] Supply pressure [MPa] ZU07SA Exhaust Characteristics Exhaust Characteristics Flow Rate Characteristics Flow Rate Characteristics ZU07LA 100 80 100 50 60 50 Vacuum pressure Vacuum pressure Air consumption [L/min(ANR)] Suction flow rate [L/min(ANR)] Air consumption [L/min(ANR)] Suction flow rate [L/min(ANR)] 50 80 80 40 40 Vacuum pressure [kPa] Vacuum pressure [kPa]

For 90 rotation Single vane (S): 80 to 100 adjustable Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 180 10 10 22.5 Allowable radial load (N) Size Allowable thrust load (N) Positioning pin hole 20 1 15 40 3 30 50 7 60 Adjustment bolt (A) Adjustment bolt (B) 60 20 80 Single vane (S): 170 to 190 adjustable For 180 rotation 11-5-6 6 Series MSUA Rotary Table:

(at 80 mA load current) PNP: 1.5 V max. (at 80 mA load current) Response time 25 0.5 s/1 s/2 s Output protection Short circuit protection Flow Selects one of the output (hysteresis or window comparator mode), the output for the accumulated flow and the accumulated pulse output. Output mode Temp. Selects the output for fluid temp.

Home Position Return Method .80 6.1 Position Control Mode (Pulse Input). 80 6.2 Positioning mode (point table) . 80 6.2.1 Stopper type home position return . 81 7.

M4x0.7x22L 20 NBA-088S 25 NBA-106S (mm) 32 BGS1-032S 40 BAF-04S 50 BAF-05S 63 BAF-06S 80 BAF-08S 100 BAF-10S D-G5BA mm 20 25 32 40 50 63 80 100 D-G5BA 5 5 5.5 6 7 7.5 7.5 8 30% 1 2 2 mm mm D-G5BA A B Hs 20 25 31.5 31.5 24 26 24 25 28 36 36 46 80 28.5 32 40 50 63 32.5 33 37 36.5 45.5 45.5 42 48.5 57.5 56 100 57 46 68 (mm) 10 20 75 15 3. 3-1. 1 2 3 4 5 6 7 8 9 10 1 2 3 416

YES NO NO 2 YES YES NO NO YES 10 2-2 (CEU2) (AC100V,15) (24V10,0.4A) (0.3MPa0.5MPa) 3) () (CE1-R**) (CE2**) 11 2-3 40 VFS240R VFS210 AR425 8/6 AN200-02 AS4000-02 50 VFS240R VFS210 AR425 10/7.5 AN200-02 AS4000-02 63 VFS340R VFS210 AR425 12/9 AN300-03 AS4000-03 80 VFS440R VFS310 AR425 12/9 AN300-03 AS420-03 100 VFS440R VFS310 AR425 12/9 AN400-04 AS420-04 12 * 3. 3-1 () 40 50 63 80

Description Qty Note For D-S/T79, S7P, R73/80 1. Mount the magnet lever (4) to the shaft of the body (1) using the hexagon socket set screw (5). 2. Mount the cover (A) (8) to the body (1) using the cross recessed round head screws (12). (tightening torque is approx. 0.8 Nm). 3.

40 40 40 40 80 AN LECPA ( AN LECPA NPN NPN AP AP PNP PNP (m) () 8 8 8 8 L L 1.5 1 1.5 1 A A 10 10 3 3 3 3 B B 15 15 5 5 5 C C 20 20 5 () () R R S S / P.42 7.3 <> (NPNPNP) LEHF10K2-16 3 - 3.3 9 13 16 10 18 15 8 11 6 ( 12 4 5 7 2 1 3 17 14 1 2 A 3 B 4 + 5 6 + 7 + 8 9 10 A 11 B 12 13 NBR 14 15 16 17 18 ( DC24V) 4 - 4.

JXC-OMY0004-A 18.5 Power supply 80 18.6 Grounding 80 18.7 Maintenance 80 19. Troubleshooting 81 20. Handling of sent/received data 87 21. Definitions and terminology 88 -4No. JXC-OMY0004-A JXCPH/Controller 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

JXC-OMU0026 Supplement 1.7 Initial setting of LEH series Model LEHZ(J)10 LEHZ(J)16 LEHZ(J)20 LEHZ(J)25 LEHZ32 LEHZ40 Lead symbol K Lead [mm] 251/73 (3.438) 249/77 (3.234) 246/53 (4.642) 243/48 (5.063) 242/39 (6.205) 254/43 (5.907) Max. speed [mm/s] 80 80 100 100 120 120 Min. speed [mm/s] (Independent and interpolation) 5 5 5 5 5 5 Min. speed [mm/s] (Speed tuning control) 8 8 8 9 9 9 Model

80 100 100 120 120 [mm/s] () 5 5 5 5 5 5 [mm/s] () 8 8 8 9 9 9 -110No.JXC-OMT0001CN-C LEHF10 LEHF20 LEHF32 LEHF40 K [mm] 40/15 50/15 70/16 70/16 (2.667) (3.333) (4.375) (4.375) mm/s 80 100 100 100 [mm/s] () 5 5 5 5 [mm/s] () 7 8 8 8 LEHS10 LEHS20 LEHS32 LEHS40 K [mm] 255/76 235/56 235/40 235/40 (3.355) (4.196) (5.875) (5.875) mm/s 70 80 100 120 [mm/s] () 5 5 5 5 [mm/s] () 8 8 9 9

When movement starts again from the pushing stopped state, the pushing operation is repeated with the normal pushing force. 0B INP (Example) Step data force is 100% Step data Trigger LV is 80% The energy saving setting of the electric actuator is 40% *1) INP [ON] Force () 100 Trigger LV 80 Power saving mode 40 Time *1) The electric actuator model determines the energy settings.

. / . 80 19.1 . 80 19.2 . 81 19.3 . 82 19.4 . 83 19.5 . 84 19.6 . 84 20. . 85 20.1 / . 85 20.2 . 85 20.3 . 87 20.4 . 87 20.5 . 88 20.6 . 88 20.7 . 88 21. . 89 22. . 93 23. . 97 24. . 98 3 - LECPMJ / 1 *1) (ISO/IEC) (JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.

(Page 11) 7 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig 1. Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.

The following shows an example of switching cycle count value 10.000.000 cycles according to the transmission method of the upper communication. 10.000.000(dec) = 80 96 98 00 (hex) (little endian) 10.000.000(dec) = 00 98 96 80 (hex) (big endian) *: For details of conditions that output switching count, refer to note out of the table in page 19. -20No.EX-OMW0016-A Structure of Output Open

80 100 100 120 120 Min. speed [mm/s] (Independent and interpolation) 5 5 5 5 5 5 Min. speed [mm/s] (Speed tuning control) 8 8 8 9 9 9 -110No.

. -13No.PS-OMO0002-A Internal circuit and wiring example -21 Switch output NPN open collector output 2 outputs Max. 30 V, 80 mA -22 Switch output NPN open collector output 2 outputs Max. 30 V, 80 mA Analog output: 1 to 5V (5%F.S.)