for5/32 VVQ1000-51A-N3 One-touch fitting for1/4 VVQ1000-51A-N7 SY5000 One-touch fitting for5/16 VVQ1000-51A-N9 Note 1)P and R ports cannot be changed.
Applicable blank plate assenbly SY100-77-1A VZ P R 20 stations 20 R port VS A port M5 X 0.8 P port M3 X 0.5 M5 X 0.8 M5 X 0.8 Note 1) SY114 (A) and SY124 (A) cannot be mounted on the same manifold.
M3 X 0.5 SYJA314-M5 N.C. 39 (Without sub-plate 18) Base mounted (With sub-plate) M5 X 0.8 1.8 (0.1) SYJA324-M5 N.O.
FGDTF*-06 (5) FGD-CV006-03 FGDCE*-03 FGD-CV006-04 FGDCE*-04 FGD-CV006-06 FGDCE*-06 FGD-OP001 FGD*B (10) KT-FGDC FGDC KT-FGDE FGDE (2)(4)(6)(13)(16) KT-FGDT FGDT KT-FGDF FGDF FGD-CA002 FGDT,F(L250) (7)(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.
FGD-KT002 FGDE Nut kit FGD-KT003 FGDT FGD-KT004 FGDF FGD-CV005-03 FGDT,F-03 FGD-CV005-04 FGDT,F-04 FGD-CV005-06 FGDT,F-06 Replacement cover (5) FGD-CV006-03 FGDC,E-03 FGD-CV006-04 FGDC,E-04 FGD-CV006-06 FGDC,E-06 Joint FGD-OP001 FGDB (10) KT-FGDC FGDC Each of (2)(4)(6)(13) and (16) are provided as a kit.
to 10 ALD900-12 to 20 , 1 4 3 175 250 135 209 460 613 175 250 2 1 1 1 4 1 2 , , ALDU600-06 to 10, ALDU900-12 to 20 D.P.
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Recommended air flow Tubing size Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Unrestricted 360 piping tube mounting. The connector for the IN side is a universal joint type that enables a tube to be connected in any direction within 360.
FH100 Series How to Order 0 0 0 06 P 005 FH100 Made to Order Hydraulic filter Nil X0 None (Standard) Non-standard filtration Note) The non-standard filtration is for micromesh elements only.
W1 W1=NEMA 4 ISO Size Port Thread Code 1 Size 1 2 Size 2 3 Size 3 NIL Rc (PT) T NPTF F G(PF) Location of port 1(P), 5(EA), 3(EB) Number of Stations D D side 2 2 stations U U side B Both side 9 9 stations Size of port 1(P), 5(EA), 3(EB) Symbol Size Applicable ISO size 02 1/4 Size 1 U side option 03 3/8 Size 1, 2 SU0 No option 04 1/2 Size 1, 2 SUQW DeviceNet serial interface (Note) 06
to 10 ALD900-12 to 20 , 1 4 3 175 250 135 209 460 613 175 250 2 1 1 1 4 1 2 , , ALDU600-06 to 10, ALDU900-12 to 20 D.P.
EX245-SPN1 16 Valves (16 coils)32 Valves (32 coils) 2 2 4 D 0 1231 0.X byte Valves (16 coils) Valves (32 coils) 0 Valve coils 0-7 Valve coils 0-7 1 Valve coils 8-15 Valve coils 8-15 2 Valve coils 16-23 3 Valve coils 24-31 . 6-2 46 No.EX-OMU0020CN 6.4.
(Example): CDU20-25D Bore size 6, 10, 16, 20, 25 32 32 32 Type M5 x 0.8 Rc 1/8 NPT 1/8 G 1/8 Symbol D Double acting CU Nil TN TF CQS Standard stroke (mm) 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40, 50 CQ2 RQ Applicable Auto Switches/Refer to pages 1263 to 1371 for further information on auto switches.
Lock Specifications 25 32 40 50 Size Locking action Unlocking pressure Locking pressure Locking direction Spring locking (exhaust locking) 0.2MPa or more 0.05MPa or less One direction (extension locking, retraction locking, each type) 0.7MPa Symbol Maximum operating pressure Extension locking Retraction locking 245 403 629 982 M5 x 0.8 Rc, NPT, 1/8 Unlocking port connection size W Holding
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
0.2 MHZ2-16D 7 4 M5 x 0.8 M5 x 0.8 M5 x 0.8 14.9 20.9 6.6 12.6 11.6 2.1 4 MHZ2-20D 9 5 M5 x 0.8 M5 x 0.8 M5 x 0.8 16.3 26.3 7.2 17.2 14 2.1 4 MHZ2-25D 6 12 M5 x 0.8 M5 x 0.8 M5 x 0.8 19.3 33.3 8.8 22.8 19 3.5 4 Note) Through-hole mounting is not possible for 10. 925 Standard Type / Series MHZ2 Finger Option 1122Air Preparation Equipment Pressure Control Equipment Flow Control Equipment
SI unit for DeviceNet /PROFIBUS As a slave for DeviceNet/PROFIBUS, it is possible to control ON/OFF of a solenoid valve with the maximum of 32 points. Furthermore, by connecting a discrete input block, it is possible to input the sensor signal for 32 points at the maximum.
M5 x 0.8 for CQ2X 32-5 Auto switch specifications Lead wire length (m) Load voltage Direct mounting Rail mounting Indicator light Special function Wiring (output) Electrical entry Applicable load None (N) Type 32 to 100 32 to 100 0.5 (Nil) 3 (L) 5 (Z) DC AC In-line In-line Perpendicular Perpendicular 3-wire (NPN equiv.) 5V A76H A96V A96 IC circuit 200V A72H A72 Yes Reed switch Grommet
This is for reference. *8 Indicates case of grommet type Flow Rate Characteristics Face seal fitting/Compression fitting XSA1-12 XSA1-22 XSA2-22 XSA2-32 XSA2-43 XSA3-32 XSA3-43 Flow rate characteristics C[dm3/(sbar)] 0.55 1.07 1.07 1.51 2.78 1.54 2.89 b 0.41 0.36 0.34 0.24 0.21 0.24 0.21 (Rc, NPT) Female thread XSA1-11 XSA1-21 XSA2-22 XSA2-32 XSA3-33 XSA3-43 Flow rate characteristics C[dm3
M5 x 0.8 (Finger closing port) When auto switches are used, through hole mounting is not available. 637 Series MHC2 Double Acting: Size 20, 25 MHC2-20 2 x M5 x 0.8 thread depth 8 (Mounting thread) 4 x M5 x 0.8 thread depth 10 (Mounting thread) Bottom hole dia. 4.3 through (Mounting hole) 2 x M5 x 0.8 thread depth 10 (Mounting thread) Auto switch mounting groove (Both sides) 4 x M4 x 0.7