80 85 90 95 100 105 60 65 70 75 80 85 73 78 83 88 93 98 16 to 25 Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R QA Q GC GB E MM GA D J C 2.8 A Width across flats L 2 x P through A1 H E 4 x T counterbore 0.5 B S Z (mm) S Z A A1 GB P Q QA R T B C D E GA GC H J L MM Bore size 5 30 40 50 5 10 15 20 25 30 40 50 10 15 20 25 20 16 12 11 5.5 4.5 9 4 4.5 2 16 12 26 20 40 32 8 6 30 27 M6 x 1.0

Description Ethernet UCMP Echo request (Ping command) received Orange LED is flashing PI 1 TX+ 1 2 Forced output mode is ON Orange LED is ON RX+ 2 No Link, No Activity (Port1) LED is OFF 3 4 3 TXLink, No Activity (Port1, 100 Mbps) Green LED is ON 4 RXL/A1 Link, Activity (Port1, 100 Mbps) Green LED is flashing Link, No Activity (Port1, 10 Mbps) Orange LED is ON Summary of Product parts CAUTION

[GSDML ] PLC [SC_MonSs] [Monitior Short Enable 1 Circuit(Power) ] Disable 1 Enable [OC_Mon] [Monitor Open 2 2 Disable Circuit] [Inrush] [Inruch Current Enable 100 mse 3 Disable Filter] 0.1 ms [Filter_T] [Input Filtering 1.0 ms 4 1.0 ms 10 ms Time] 20 ms 1.0 ms [SigExt_T] [Input Extention 15 ms 15 ms 5 100 ms Time] 200 ms Enable Val: 1 65000 4 ON/OFF [Counter] []

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

No.CG1*-OM0006N / / C*G5*N**SR/V-* C*G5*A**SR/V-* P2 P4 1. P6 1-1. 2. P7 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. 2-8. 3. P16 3-1. 3-2. 3-3. 3-4. 4. P24 5.

Specification 1.1 AC servo motor 1.1.1 How to order L E J S 100 T9 B 500 T X400 Lead [mm] Motor type Stroke [mm] H 50 200 200 T9 AC servo motor to to A 25 1500 1500 B 10 *Refer to the applicable stroke table.

Clean Tubing Polyolefin Tubing Series TPH RoHS How to Order TPH0604 B 20 Tubing model Color Length per roll Symbol W B R BU Y G Color White Black Red Blue Yellow Green Symbol 20 100 Length 20 m roll 100 m reel 20 m roll 100 m reel Burst Pressure Characteristics Curve and Operating Pressure Model TPH0425 4 2.5 TPH0604 6 4 TPH0806 8 6 TPH1075 10 7.5 TPH1209 12 9 Model O.D. (mm) I.D.

Tubing model KFG2 Symbol 20 100 Length 20 m roll 100 m roll Precautions MS Color KKA Be sure to read this before handling the products.

reduction Current model IR3000 Series Approx. 100% reduction 49000 yen reduction 150 150 128000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1200-A Series IR2200-A Series 50 50 IR3200-A Series 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Bleed air 0 IR No fixed throttle in the new design.

Piston Speed 40 Without stroke adjusting unit 16 25 Bore size (mm) Note 1) 100 to 1000 mm/s L unit and H unit Stroke adjusting unit 100 to 1500 mm/s Note 1) When exceeding the air cushion stroke ranges on page 1094, the piston speed should be 100 to 200 mm/s. Note 2) Use at a piston speed within the absorption capacity range. Refer to page 1094.

Membrane Air Dryers 361 405 428 468 548 618 83 187 53 113 212 54 1/4 73 140 40 Port size L B A Port size L A B C 70 91 3/8 1/2 3/8 IN Port size: 1/4 OUT Port size: 1/4 IDG30, 30L IDG50, 50L IDG60 IDG75, 100 IDG60L, 60S IDG75L, 75S IDG100L, 100S Model Model (67) (46) (26) IDG3, 5 IDG10 IDG20 Width across flats 17 Width across flats 14 Width across flats 14 Purge air outlet for dehumidification

600/150 / AC200V 1600/100 2400/150 XL1A25-60S-3 XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200/180 1[W] 216 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0001 5 5-1 1 , SUS304 8 4 SUS304 10 , SUS316L 7 5 A6063 2 1 6 SUS304 3 2 9 2 SUS304 SUS304 11 XL-OMY0001 5-2 C E E E KF K Fd Fn C D H B A G A mm A B C D E Fn Fd

common) Output points 16 points Output specification 24 VDC Solenoid valve with a surge voltage suppressor of 2.1 W or less, made by SMC Connection load Output of communication error Hold/Clear (set through network) Enclosure IP20 Operating temperature range 0 to +55 C (8 valves on) 0 to +50 C (16 valves on) Environment proof Operating humidity range 35 to 85RH (no dew concentration) Withstand

ITV2-OM00095-C P R O D U C T N A M E E/P Regulator (DeviceNetTM type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-DE* Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Specifically, read the safety instructions carefully. Keep this operation manual available whenever necessary.

Flow Characteristics/Weight C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Operating pressure range (MPa) Port size Grommet DIN terminal 0.10 0.13 0.13 0.10 0.13 0.13 0.13 0.13 0.13 0.13 0.41 0.32 0.32 0.41 0.32 0.59 0.32 0.32 0.59 0.32 2 3 2 3 2 3 VKF33 VKF33 Y VKF33 E VKF33 V VKF33 W VKF334 VKF334Y VKF334E VKF334V VKF334W 0.67

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series

kPa to 0.2 Proof pressure [MPa] 0.6 Ambient and fluid temperatures [C]*2 0 to 50 C [dm3/(sbar)] 0.25 0.12 0.5 Cv 0.07 0.032 0.14 b 0.25 0.25 0.3 Flow rate [L/min (ANR)] at 0.2 MPa*4 45 22 90 Response time [msec]*3 ON, OFF: 10 or less ON, OFF: 15 or less Impact/Vibration resistance [m/s2] 150/30 Mounting orientation Unrestricted Enclosure IP40 Weight [g] 10 20 Valve specifications Inrush*

LEY25: 200 or less LEY32: 100 or less 3. In case of [Double clevis], use the actuator within the following stroke limit. LEY16: 100 or less LEY25: 200 or less LEY32: 200 or less 4. G Head flange is not available for LEY32. Nil 1 3 5 8 A B C Without cable 1.5 3 5 8 !

Temperature range (C) Pressure range (MPa) Required flow rate Note 12) (50/60 Hz) (L/min) 5 to 40 0.3 to 0.5 8 0.3 or more 5 to 40 0.3 to 0.5 12 0.3 or more Note 1) Inlet-outlet pressure differential of facility water (MPa) Port size Wetted parts material Rc3/8 Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Single-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz) Allowable

Specifications Port Size (Applicable Tubing O.D.): ø1/8" / ø5/32", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 50 / 80, Flow Rate (Vacuum Pressure) [L/min]: 7 / 10, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2