K M H 2-4.5 mounting hole D N-FA Applicable tubing O.D. MS T VMG Applicable tubing O.D.
Auto switch Auto Switch Specifications D-M9N-5(With indicator light) Auto switch model D-M9N-5 Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less
D-A9V/M9V/M9WV/D-M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.
EX120-SMJ1 EX121-SMJ1 -32No.EX-OMB0014-H EX122-SMJ1 EX124D/U-SMJ1 -33No.EX-OMB0014-H EX126D-SMJ1 -34No.EX-OMB0014-H Revision history C: Complete revision D: Terminal screw change Switch cover change (EX124U/D, EX126D) E: Modified errors in text.
Signal name Details 1 L+ 24 V (Control and input) 2 P24 24 V (Output) 3 L0 V (Control and input) 4 C/Q IO-Link communication, Digital input (PNP) or Digital output (PNP) 1 5 N24 0 V (Output) 1: Can be changed with parameters. Digital output power supply is used for control / input. The relationship between connector No. and IO-Link port is shown below. Connector No.
Point for measure Point for measure Offset voltage (V) Discharge Offset voltage(V) Discharge time (s) time (s) ment ment (1) 1.3 0.20 (1) 0.0 0.19 (2) 2.5 0.34 (2) 0.6 0.40 Notes: When additional air flow pressure is set to 0.2MPa and supply pressure to the dust collector to 0.3MPa.
Discharge time is the time required to reduce electricity on the static plate (150 mm x 150 mm, static capacity 20 pF) from 1000 V to 100 V. The above shown values are measured using SMC's measurement instruments and conditions, and not the guaranteed values.3. Ionizer Functions -13- 3. Ionizer Functions 3.1 Functions 1.
Stations: Stations, Wiring: D-sub Connector, Manifold Options: with Manifold Options B & D, Exhaust: Complex Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Leadwire: 2m Switch/Sensor Only, Unit Options: Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut, 1st Nominal Nozzle Size: ø1.0, 1st Selection Supply
. & / a) (52) b) 28 c) /(16) d) e) (51) f) g) h) OFF ON i) j) (51) k) (SIDXDYDM) ON/OFF ON SI 030 (DXDYDM) 1 -17No.EX-OML0010CN-C a) (52 ) b) (28 c) /(16 ) d) e) (51 ) f) g) h) Offset binarySign & Magnitude2S Complement mA() V() Scaled mA() V() i) j) (51 ) -18No.EX-OML0010CN-C 3.
D-M7BA# Sheath Outside diameter (mm) 2.6 Wires 2-wire (Brown, Blue) Insulator Outside diameter (mm) 0.88 Cross section (mm2) 0.15 Conductor Wire diameter (mm) 0.05 Min. bending radius (mm) (Reference value) 17 -15No.D-S-OMZ0004 Dimensions D-M7BA# Pre-wired connector A B D-M7### PC D-M7###DPC -16No.D-S-OMZ0004 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3
Auto switch Auto Switch Specifications D-M9(With indicator light) Auto switch model D-M9N D-M9P Electrical entry direction In-line Wiring 3-wire Output NPN type PNP type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage DC28V or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less
ZL-OM00801 Circuit Diagram ZL112 ZL112-K1*-D*** A ZL112-K2*-D*** A ZL212 22 - Doc. no. ZL-OM00801 Weight 23 - Doc. no. ZL-OM00801 Exhaust Characteristics and Flow Characteristics of Ejector 24 - Doc. no.
, PLC Yes Grommet 24 V IC circuit Diagnostic indication (2-color display) 5 V, 12 V 12 V Solid state auto switches marked with are produced upon receipt of order.
/N.C.), 3rd Selection Vacuum V Port: 8 (Vacuum, V Port: Ø8), 3rd Selection Quantity: 4
The load does not work. -16No.D-S-OMS0002-B Specification Specifications Model D-M9NJ D-M9PJ Output type NPN type PNP type Power supply voltage 20 to 26 VDC Current consumption 25 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less Leakage current 100 A or less at 24 VDC Indicator light Operating range: The red LED lights up.
A One-touch Mini Fittings Miniature Fittings Auto switch model (KQ2H/KQ2S/KQ2L/KQ2W M-3AU / M-3ALU KJH/KJS/KJL/KJW) D-M9 (V) NG OK D-M9 W(V) NG OK D-M9 A(V) NG OK OK: No interference NG: With interference Auto switch Auto switch interferes fitting interferes the fitting NG: With interference OK: With interference Mounting dimensions of extension fitting With the extension fitting mounted
Air filter, mist separator and regulator unit , Clean looking, modular design , Energy saving with high flow rate , Compact spacer with bracket reduces total assembly space , Optional embedded pressure gauge , Improved installation , Rc(PT), G(PF) or NPT threads, F/MS/R COMBO MODULAR, FRL COMBO, P29, 0.52000 lb
Auto switch Auto Switch Specifications D-M9-5(With indicator light) Auto switch model D-M9P-5 Wiring 3-wire Output PNP type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage 100 A
Indicator light Yes Auto switch model Lead wire length (m) Note 1) Applicable load Applicable model Load voltage Type Special function Electrical entry Wiring (Output) 0.5 Nil 3 (L) 5 Note 2) DC Perpendicular 10 16 20 25 In-line AC (Z) Solid state auto switch M9NV F8N M9PV F8P M9BV F8B M9N M9P M9B 3-wire (NPN) 5 V 12 V IC circuit Relay PLC 3-wire (PNP) 24 V Grommet 2-wire 12 V Note 1