Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. Fluid: air
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 1/4, VALVE, AV SOFT START UP BODY PORT, EA, AV BODY PORT 1/4 NPT, .88184 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A)
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 1/2, VALVE, AV SOFT START UP BODY PORT, JA, AV BODY PORT 1/2 PT, 1.80779 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 1/2, VALVE, AV SOFT START UP BODY PORT, 1A, AV OTHER SIZE RATING, 1.76369 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet
Direct Operated 2-Port Solenoid Valve, 2 WAY SOLENOID VALVE, O68, 380.00000 lb
Direct Operated 2-Port Solenoid Valve, 2 WAY SOLENOID VALVE, O68, 370.00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 4730.00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.40924 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption (W) (Holding)Temperature rise (C)(Rated voltage) InrushHoldingVXP22AC5040187.560
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.03025 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (Holding)Temperature rise (C ) (Rated voltage) InrushHoldingVXR22AC5040187.560
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.02814 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (Holding)Temperature rise (C ) (Rated voltage) InrushHoldingVXR22AC5040187.560
Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.18878 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (
Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.18878 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (
Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.18878 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.18878 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (Holding)Temperature rise (C ) (Rated voltage) InrushHoldingVXR22AC5040187.560