It cannot be adjusted by a shock absorber. 10 to 80 C Ambient temperature range DSpring force: (N) Extended 1.96 4.22 6.86 8.34 Retracted 3.83 6.18 15.3 20.50 -X It denotes the values at the maximum energy absorption per one cycle. Therefore, the operating frequency can be increased according to the energy absorption.

Pilot port Rc, NPT 1/8 12 R 132 100 42.3 91 116 1 2 SMC 4 x 6.5 (Mounting hole) 80 OUT IN 100 6 HEX.35 (178) With nut 80 Pilot port Rc, NPT 1/8 12 R 132 100 116 1 2 SMC 4 x 6.5 (Mounting hole) 80 100 SRF50 19 Model A1 A2 B1 B2 OUT IN SRF50S-1S19 SRF50S-1S1925 SRF50S-1S25 SRF50S-1S2519 SRF50S-2S19 42.3 91 58 91 58 91 55 98 55 98 55 98 A1 A2 58 91 6 B1 B2 56 95 56 95 Tube extensions 80

PSE200-(M) : NPN open collector 5 outputs + Auto-shift 1 input Max. 30 V, 80 mA Residual voltage 1 V or less PSE201-(M) : PNP open collector 5 outputs + Auto-shift 1 input Max. 80 mA Residual voltage 1 V or less -17No.PS-OMH0006-F Setting of Function Setting procedures Measurement mode Detects pressure, displays values and performs switching.

Maximum load current 80 mA Maximum applied voltage (NPN output) 30 VDC Switch output Internal voltage drop (Residual voltage) NPN: 1 V or less (Load current 80 mA) PNP: 1.5 V or less (Load current 80 mA) Delay time 1 1.5 ms or less (delay time available for anti-chattering function: 20, 100, 500, 1000, 2000, 5000 ms) Hysteresis mode Variable from 0 2 Window comparator mode Hysteresis Protection

mA 1 V Max.30 V80 mA 1 V 15 V 1 k DC+ DC+ OUT1 OUT1 OUT2 OUT2 DCDCPSE34(T) PSE35(T) PNP 2 PNP 2 Max.80 mA 1 V Max.80 mA 1 V 420 mA 300 (DC12 V) 600 (DC24 V) 50 DC+ DC+ OUT1 OUT1 OUT2 OUT2 DCDC-15No.PS-OMG0001CN-H 1 M [S_J] [S_F] 2Sor 1 LCD ON ON OFF OFF [] 2(SorSoG) LCD OUT2 OUT1 [] 3 () 1MPa -101kPa 100kPa 500 kPa 100kPa 2 kPa 4([M]) LCD 2 bar psi inHg mmHg kPa

Problem Possible cause Investigation method Countermeasure (1)(2) Connect the (1) Check if the output current is 80 mA or more. appropriate load. (2) Check if the specified load is (3) Use a relay with a surge connected. voltage suppressor or take measures to prevent noise.

mA Max. applied voltage 30 VDC (NPN output) Internal voltage drop NPN output: 1 V or less (at 80 mA) PNP output: 1.5 V or less (at 80 mA) Switch output Response time 1 s or less Repeatability 1%F.S. max.

HRZ***-WS-F : 110 deg C HRZ***-W1S-F:100 deg C HRZ***-W2S-F:80 deg C HRZ008-L/L1-F :60 deg C 10 Return High Temp WRN Continued Check the circulating fluid flow rate, load specification. The temperature of the circulating fluid exceeded your set value.

80 100 100 120 120 [mm/s] 5 5 5 5 5 5 () [mm/s] 8 8 8 9 9 9 () 110 No.SFOD-OMT0009CN-B LEHF10 LEHF20 LEHF32 LEHF40 K [mm] 40/15 50/15 70/16 70/16 (2.667) (3.333) (4.375) (4.375) [mm/s] 80 100 100 100 [mm/s] 5 5 5 5 () [mm/s] 7 8 8 8 () LEHS10 LEHS20 LEHS32 LEHS40 K [mm] 255/76 235/56 235/40 235/40 (3.355) (4.196) (5.875) (5.875) [mm/s] 70 80 100 120 [mm/s] 5 5 5 5 () [mm/s] 8 8 9 9

L M N P Q R S T U V W X Y AV2000-02-1 to 6D/Y(Z)-A 30 50 51.5 44 5.5 10 66 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 14 AV3000-03-1 to 6D/Y(Z)-A 41 50 53.5 46 5.5 15 70 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 19 AV4000-04-1 to 6D/Y(Z)-A 50 60 64 54 8.5 18 90 3.2 39 74 M5 x 0.8 Depth 6.5 4 Width across flats 22 AV5000-06,10-1 to 6D/Y(Z)-A 70 75 70 60 11 16 100 3.2 45 80

IZE110 NPN open collector output: 2 outputs Max. 30 V, 80 mA Residual voltage 1 V or less Analog output: 1 to 5 V Output impedance: Approx. 1 k IZE111 NPN open collector output: 2 outputs Max. 30 V, 80 mA Residual voltage 1 V or less Analog output: 4 to 20 mA Max. load impedance: 600 (at 24 VDC) Min. load impedance: 50 IZE112 PNP open collector output: 2 outputs Max. 80 mA Residual voltage

40.5 0 28 41.5 27.8 52 f42.5 78 f42.5 78 f42.5 78 AW40K-06-D 3/4 1/8 75 149.1 93 40.5 38.4 M421.5 80 40.5 0 28 41.5 27.8 52 42.5 78 42.5 78 42.5 78 AW60K-D 3/4, 1 1/8 95 234.1 155 50 38.4 M621.5 30 50 0 28 51 27.8 61.5 42.5 87.5 42.5 87.5 42.5 87.5 Optional specifications Semi-standard specifications Metal bowl with PC/ PA bowl Metal bowl level gauge With auto A4 Panel mount Model Bracket

. -25 NPN open collector output Max.30 V, 80 mA Residual voltage 1 V or less -65 PNP open collector output Max.80 mA Residual voltage 1 V or less -10No.PS-OMJ0004-E Pressure Setting Operation When the pressure exceeds the set value, the switch will be turned ON. When the pressure falls below the set value by amount of hysteresis or more, the switch will be turned OFF.

C96*-MM0049Q 4 Tube Trunnion bore part number 32 V5032P 40 V5040P 50 V5050P 63 V5063P 80 V5080P 100 V5100P Product image CP96S*V*-* 125 V5125P 4 1 5 2 3 Component parts No. Description Qty Notes 1 Trunnion 2 2 Retaining bracket 4 3 Trunnion pin 2 4 Hexagon socket head cap screw 8 4 32 to 80 8 100, 125 Set screw 5 Assembly Procedure No.

Grease (10g): 1 bag 80 CA2Y80-PS 100 CA2Y100-PS 40 CA2Y40Z-PS Piston seal: 1 pc. 50 CA2Y50Z-PS Rod seal: 1 pc. 63 CA2Y63Z-PS CA2Y Tube gasket: 2 pc. 80 CA2Y80Z-PS Grease (10g): 1 bag 100 CA2Y100Z-PS 20 CM20Z-PS 25 CM25Z-PS CM2Y Rod seal 32 CM32Z-PS 40 CM40Z-PS 20 CG1Y20Z-PS Piston seal: 1 pc. 25 CG1Y25Z-PS Rod seal: 1 pc. CG1Y 32 CG1Y32Z-PS Tube gasket: 1pcs.

Table 10 Bore size(mm) Hexagon socket head cap screw Width across flats Tightening torque(Nm) A 32,40 MB-32-48-C1247A 4 5.1 B 50,63 MB-50-48-C1249A 5 11 Foot MB-80-48AC1251A 6 25 Other MB-80-48BC1251A 80,100 125 Foot M12X1.75X25(thin socket head) 8 30.1 Other M12X1.75X28(thin socket head) 5)When replacing mounting brackets, tie-rod nuts on the cylinder body become loosened.

MPa] When the arm length is 80 mm, pressure should be MK20/25: 0.45 MPa or less, MK32/40: 0.55 MPa or less.

LEFT RIGHT 68 0.2 2.5sec or more required 35.5 80 4 56 DOWN SEL.

P-80 (JT) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.