Fluids VCC Series Union Nut Socket 1209 1008 1075 VCC-G-D-1 (Applicable fitting VCK ) VCC-G-D-1 2 13 Width across flats: 19 25.5 14 60 VCC-G-D-2 (Applicable fitting VCK ) 0806 0604 9 Width across flats: 17 20.5 14 50 For extending the socket VCC-G-D-1 VCC-G-D-1 VNA 113 VNB SGC SGH VCC-G-D-1 VNC VNH VCC-G-D-2 VND 97 VCC VCC TQ 655 VCC Series Disassembly/Assembly/ Maintenance Procedure Cleaning
Note 2) Value on option "V" (Non-leak, Vacuum).
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AC MASS PRO 1/2 MODULAR (NPT), AIRLINE EQUIPMENT, AC MASS PRO, FC, AC MASS PRO 1/2 MODULAR (NPT), 4.71789 lb
ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.
Green OFF COM D has no received data. COM D Green ON COM D is receiving data. NOTE When connecting manifold valve only without connecting Input unit manifold, LEDs of COM A D do not light.
A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)
, Tool required L plug connector Locking type (Manual) Single Locking type Closed center Double Exhaust center Pressure center Grommet Plug-in 12 V 24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz 4/2 5/3 (A/B R1/R2) 3 position Closed center Double Single Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal VQ130 0.73
Designation Content 1 SV24 V (PWR(V)) +24 V for valves 2 SV0 V (PWR(V)) 0 V for valves 3 SI24 V (PWR) +24 V for logic/sensors 4 SI0 V (PWR) 0 V for logic/sensors Fig. 2-4 Pin allocation of M12 4 pin plug A-coded connector Power-supply line for valves and power-supply line for logic/sensors operation are isolated. Be sure to supply power respectively.
AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 Cuts air consumption by operating the return stroke at a reduced pressure.
(A/D ) ( ) 6 2030 20 80 mA (Er1,2) () ( (Er4,6,7,8) ) DC1224 V DC1224 V Er1,2) Er4,6,7,8) 7 (HHH) "HHH" "LLL" Er3) (LLL) (Er3) 7F.S. -27No.PS-OMG0001CN-H No. DC1224 V DC1224 V 8 DC(+) DC(-) DC1224 V DC1224 V DC(+) 9 DC(-) / / 10 ( ) 11 / 5m / 12 2030 20 -28No.PS-OMG0001CN-H No.
OUT() DC(-) DC(+) PSE57--28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -13No.PS-OMS0004CN-D (A/D ) () 20 2030 -14No.PS-OMS0004CN-D PSE570 PSE573 PSE574 01MPa -100100 kPa 0500 kPa 3.0MPa 600 kPa 1.5MPa oC) oC) (25 ) 2F.S.(050 3F.S.(050 oC) oC) 3F.S.(-1060 4F.S.(-1060 PSE57PSE57--28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 oC) 1.0F.S. 0.5F.S. oC)
V 4 Q D 1 5 Clean series Manifold type 2 Body ported 5 Base mounted Valve stations 02 2 stations 20 20 stations (Maximum) Port size M5 M5 x 0.8 C4 4 cassette Note) 1(P), 3(R) ports: Rc1/8.
S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type VQZ VZ VS For AC (50/60Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] VFN Light/Surge voltage suppressor Electrical entry Nil R U Z For DC, AC Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor 24 V, 12 V, 6 V, 5 V, 3 VDC/100
IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 134 Thermo-chiller Inverter Type HRSH090 Series Circulating Fluid Temperature
as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 97 Thermo-chiller Standard Type HRS100/150 Series
tubing O.D.: 3.2 Vacuum (V) port Applicable tubing O.D.: 4 Vacuum (V) port Applicable thread size: M5 Vacuum (V) port VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-50A-M5 5.9 5.9 5.8 (3.7) VVQ1000-F1-LC3 VVQ1000-F1-LC4 21.4 21.4 Applicable tubing O.D.: 3.2 Vacuum (V) port Applicable tubing O.D.: 4 Vacuum (V) port 7.9 7.9 10 10 9.2 9.2 V port
(Range) (Lwr_Lmt) (Upr_Lmt) -10..10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..5 V 5.25 to + 5.22 V 5.22 to +5.25 V -20..20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00 mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA -52No.EX-OMN0034
Designation Description 1 SI24 V +24 V for SI unit operation 2 SV24 V +24 V for solenoid valve 3 SI0 V 0 V for SI unit operation 4 SV0 V 0 V for solenoid valve : Recommended mating M12 5-pin socket, part no. EX500-AP00and PCA-1401804. (Refer to page 40) The M12 connector cable has two types, SPEEDCON compatible and non-compatible.