A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking PIN PLATE CYLINDER.

Perform the various settings. (1) Name: Input a unit name of your choice. (2) Comm Format: Select the data format of the Connection Parameters. (3) IP Address: Input the IP Address of the SI unit. (4) Assembly Instance: Set as follows: Input = 100 Output = 150 Configuration = 105 (5) Size: Set as follows: Input = 2 bytes (for Data-SINT) = 1 word (for Data-INT) Output = 4 bytes (for Data-SINT

Safety cannot be assured in the case of unexpected malfunction. 7 3 5 6 9 1 2 4 8 10 0 Blue : 24 VDC (for input and controlling) 118.5 76.5 97.5 108 139.5 55.5 66 87 129 150 L1 45 4 3 Black : 0 V (for input and controlling) 236.8 152.8 194.8 215.8 278.8 L2 110.8 131.8 173.8 257.8 299.8 89.8 Power supply connector Provide grounding to assure the safety and noise resistance of the Fieldbus

Displays the diagnosis status of the unit. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 IP address is duplicated. Connection timeout. Connection is established. Recoverable error. The unit is in normal operation. The power supply for control and input is Off. The element in SI unit is broken. The power supply voltage for output is abnormal.

Settings1 Intermediate reinforcing brace (EX600-ZMB2) 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Mode Diagnostic size set for the input Content 2 Vibration resistance NOTE for 2 hours each in direction X, Y and Z respectively (De-energized) 0 OFF 0 byte Input data only (default setting) 147 m/s2 3 times each in directions of X, Y and Z respectively

. : This switch can be enabled and disabled by parameter. 10 to 57 Hz constant amplitude 0.75 mm p-p 57 to 150 Hz constant acceleration 49 m/s2 for 2 hours each in direction X, Y and Z respectively (De-energized) Vibration resistance Diagnostic mode setting switch: Allocates the diagnostic data to the input data. Provide grounding to assure the noise resistance of the Fieldbus system.

Tightening torque: 0.7 to 0.8 Nm. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 : Mode 3 is a function for extension in the future. (not to be used.) Vibration resistance After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.

protection Enclosure IP67 (manifold assembled) 1 Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85% RH (no condensation) Environment Withstand voltage 500 VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150

10.1. . 10-1 EX245-EA2-1 . 10-2 EX245-EA2-2 70 No.EX-OMW0014CN-A . 10-3 EX245-EA2-3 . 10-4 EX245-EA2-4 71 No.EX-OMW0014CN-A . 10-5 EX245-EA2-5 72 No.EX-OMW0014CN-A 10.2. . 10-1 EX245-EA2-1 (WLH)mm 28.612061.5 120 g . 10-2 EX245-EA2-2 (WLH)mm 1412061.5 85 g EX245-EA2-2 (36 0.80.05 Nm) . 10-3 EX245-EA2-3 (WLH)mm 27.612061.5 120 g . 10-4 EX245-EA2-4 (WLH)mm 28.616061.5 150

Caution For use in Pollution Degree 3 Environment (UL508) Pollution degree OFF BUS IN side : No Link, No Activity 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 ON BUS IN side : Link, No Activity Intermediate reinforcing brace (EX600-ZMB1) When handling, assembling or replacing the units: Avoid touching any sharp metal parts of the connectors for connecting

Connected load and output rating Solenoid valve with surge voltage suppressor of 24 VDC and 1.0 W or less (manufactured by SMC) Fail safe HOLD / CLEAR / Force ON Protection Short circuit protection Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85% RH (no dew condition) Environment 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150

For use pollution Degree 3 Environment (UL508) Pollution degree Refer to the SMC website (URL https://www.smcworld.com) for more information about these settings. 10 to 57 Hz constant amplitude 0.75 mm p-p 57 to 150 Hz constant acceleration 49m/s2 2 Vibration resistance Operator for 2 hours each in direction X, Y and Z respectively (De-energized) (3)Connecting the SI unit.

Dimensions for installation L: Dimensions n: Number of stations L n 2 3 4 5 6 7 8 9 10 L1 133.4 166.4 199.4 232.4 265.4 298.4 331.4 364.4 397.4 L2 117 150 183 216 249 282 315 348 381 -11No.EX-OMY0021 Wiring Select the appropriate cables to mate with the connectors mounted on the SI unit.

Security label -20 C to 60 C Ambient temperature OFF The strength of the Fibre-Optic communication is more than 2 dB. 3 3 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 PROFINET connector for Port1 (XF1) Push Pull connector EX245-FPS1: SCRJ EX245-FPS2: RJ45 Flashing The strength of the Fibre-Optic communication is more than 0 dB but less than 2

The power supply for control and input, or the input device, is Off. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 DX E/DX F DY B/DY E/DY F Content Content Content DM E/DM F ST: STatus display LED ST: STatus display LED ST: STatus display LED

URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA

Select from 10 L/pulse and 100 L/pulse Accumulated value hold 2 2 minutes or 5 minutes Rated pressure range 0 to 1.0 MPa Proof pressure 1.5 MPa Pressure specifications Pressure loss Refer to the pressure loss graph Pressure Characteristics 3 5.0%F.S. (0 to 1.0 MPa, 0.5 MPa standard) Power supply voltage 24 VDC 10% Electrical specifications Current consumption 150 mA or less Protection Polarity

Hysteresis 150 L/min Item Default setting System error Panel mount adapter Caution Delay time 0.00 s 3000 L/min Flow range The switch output specification can be selected by pressing or button.

Display Display part Displayed digit: 3 digits 7 segments, Colour: Red Indicator LED (output) LED is ON when output is ON OUT1: Green OUT2: Red Supply voltage 12 to 24 VDC 10% Power consumption (no load) 150 mA or less 160 mA or less 170 mA or less -35No.PF-OMO0008-C Model PF2A710 PF2A750 PF2A711 PF2A721 PF2A751 Enclosure IP65 Operating temperature range Operation: 0 to 50 C, Storage: -25

0.510.5 L/min 2.552.5 L/min 5105 L/min 10210 L/min 25525 L/min / 0.1 L/min 0.5 L/min 1.0 L/min 2.0 L/min 5.0 L/min / 09 L / 1 L 3 4 -50 kPa0.5 MPa -50 kPa0.75 MPa 1.0 MPa NPN PNP 3 () 3 80 mA DC30 V(NPN ) NPN1 V (80 mA ) PNP1.5 V (80 mA ) 1 s 1F.S. 2F.S. 5F.S. 0 3 (3 digits) 50 ms 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse 5 L/pulse 5F.S. 3 7 OUT1ON OUT2ON DC1224 V10 () 150