Max. operating temperature of the TL/TIL, TLM/TILM, and TD/TID series (fixed use)
Air/inert gases: 260°C
Water: 100°C
Max. operating temperature of the TH/TIH series (fixed use)
Air/inert gases: 200°C
Water: 100°C


For details on resetting the alarm, refer to section “5.18 Accumulated Time Reset Function” in the HRS series operation manual, which can be found here.
Once the accumulated operating time reaches 20,000 hours, pump replacement is recommended.


For details, refer to section “8.4 Stop for a Long Time” in the HRS series operation manual, which can be found here.
Note) Drain the circulating fluid (as well as the facility water for HRS series water-cooled thermo-chillers) if there is a risk of freezing during the winter season.


For details on resetting alarms, refer to section “5.18 (and 5.8) Accumulated Time Reset Function” in the HRS series operation manual, which can be found here.
Note that there is no alarm code “AL29” (fan motor maintenance) for water-cooled thermo-chillers.
Note 1) Every 30,000 hours for the HRS090 to 200 and the HRSH series


The new XL□ series catalog can be found here.

An auto switch can be retrofitted in the following cases.
① When the part number on the nameplate of the product indicates it has an auto switch (e.g., XLA-40-2M9NA, etc.)


For the seal kit part numbers and the seal replacement procedure for CHKD/CHKG, CHN, CHSD/CHSG/CH2E(W), CH2F(W), CH2G/CH2H, and CHA(W) series cylinders as well as the seal kit part numbers for CHQ(W)B and CHA(W) series cylinders, refer to the “Maintenance Parts List,” which can be found here.