= (10-3 m2/s) = (mPas)/(kg/m3) 603 PAF Series Performance Curve: Air Operated Type PAF3413 Flow Rate Characteristics PAF5413 Flow Rate Characteristics 0.5 0.5 Cycle 4 Hz Cycle 3 Hz Cycle 2 Hz Cycle 3 Hz Cycle 2 Hz Cycle 1 Hz SUP = 0.5 MPa SUP = 0.4 MPa SUP = 0.5 MPa 0.4 0.4 SUP = 0.4 MPa Discharge pressure (MPa) Discharge pressure (MPa) SUP = 0.3 MPa 0.3 0.3 SUP = 0.3 MPa SUP = 0.2 MPa
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight), Vacuum, V Port: 2 (ø4, Straight
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight), Vacuum, V Port: 5 (ø4, Elbow)
Nozzle Diameter: ø1.0, Exhaust: Silencer for Manifold, Solenoid Valve Combination: Supply Valve: N.C.; Vacuum Release Valve: None, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.3m, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: Suction Filter Only, Vacuum Pressure Switch Unit Specs: Unit Switching Function, Vacuum Pressure
Nozzle Diameter: ø0.7, Exhaust: Silencer for Single Unit, Solenoid Valve Combination: Supply Valve: N.C.; Vacuum Release Valve: None, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.3m, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: 100 to -100kPa/PNP Open Collector 2 Outputs, Suction Filter, Vacuum Pressure Switch Unit Specs
Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø4, Application: Individual Item, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: Grommet w/0.3m Lead Wire, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: w/o Pressure Sensor, Air Pressure Supply, P Port: ø4, Straight, Vacuum, V Port: ø4, Elbow
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: M (Fixed SI Unit), Stations: 2
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP, 2 Outputs, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -