Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Valve Type: Normally Closed, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Right Flange Surface, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA
None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
type=GUIDE&id=XLA-E" target="_blank">here. (Details on the XL series valve with a heat-resistant auto switch can also be found in the new XL series catalog.)
Flange Size: 50, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 80, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed)
HIGH VACUUM ANGLE VALVE, ALUMINUM, HIGH VACUUM VALVE, L45, 0.40600 lb
HIGH VACUUM ANGLE VALVE, ALUMINUM, HIGH VACUUM VALVE, L45, 3.22600 lb
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: U (w/Light & Surge Voltage Suppressor
Flange Size: 16, Flange Type: KF(NW), Port Direction: A (w/Indicator, Flange Side), Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed), Non-standard Indicator: X (Non-standard Indicator), Body Surface Treatment: A (External: Hard Anodized - Internal: Oxalic Acid Anodized)
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 5m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-polar Type, Non-standard
Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: G (w/Indicator, Rear Flange Surface)
Magnet: None, Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 20mm, Stroke: 40mm, Cushion: Rubber Cushion, Rod Boot: None, Mounting Bracket: G (Flange)
Flange Size: -, Flange Type: -, Port Direction: -, Temperature: -, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m)