Model: 31, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: H (Stainless Steel, Seals: FKM, Class B), Suffix: Standard, Port Size: 02 (1/4), Thread: Rc, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Model: 31, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: H (Stainless Steel, Seals: FKM, Class B), Suffix: Standard, Port Size: 02 (1/4), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Model: 31, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: H (Stainless Steel, Seals: FKM, Class B), Suffix: Standard, Port Size: 02 (1/4), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Model: 31, Orifice: 2.2mm, Style: N.C., Single Unit, Option: Stainless Steel, Seals: FKM, Class B, Suffix: Standard, Port Size: 1/8, Thread: NPTF, Voltage: 24VDC, Electrical Entry: DIN Terminal, Surge Suppressor: w/Light and Surge Voltage Suppressor, Rectifier: None (for DC or AC Class H Coil), Bracket: Bracket
Model: 31, Orifice: 2.2mm, Style: N.C., Single Unit, Option: Stainless Steel, Seals: FKM, Class B, Suffix: Standard, Port Size: 1/4, Thread: Rc, Voltage: 24VDC, Electrical Entry: DIN Terminal, Surge Suppressor: w/Light and Surge Voltage Suppressor, Rectifier: None (for DC or AC Class H Coil), Bracket: Bracket
Model: 31, Orifice: 2.2mm, Style: N.C., Single Unit, Option: Stainless Steel, Seals: FKM, Class B, Suffix: Standard, Port Size: 1/4, Thread: NPTF, Voltage: 24VDC, Electrical Entry: DIN Terminal, Surge Suppressor: w/Light and Surge Voltage Suppressor, Rectifier: None (for DC or AC Class H Coil), Bracket: Bracket
The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, 1.04785 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX31------?1/81/4
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, 1.04646 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX31------?1/81/4
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, 1.04646 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX31------?1/81/4
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, .00000 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX31------?1/81/4
The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, 1.04646 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX31------?1/81/4
The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Function: 2 Position Double, Piping: Base Mounted, Exhaust: Base, Pressure Specification: High-pressure, 1MPa, Coil Specification: Standard, Voltage: 24VDC, Lead Wire: DIN Connector w/o Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: -, Thread: -, Made to Order: -, CE Approval: -
Function: 3 Position Closed Center, Piping: Base Mounted, Exhaust: Base, Pressure Specification: High-pressure, 1MPa, Coil Specification: Standard, Voltage: 24VDC, Lead Wire: DIN Connector w/o Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: -, Thread: -, Made to Order: -, CE Approval: -
Body Type: For Manifold, Valve Option: Continuous Duty Type, Semi Standard, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 24 VDC, Electrical Entry: w/o Connector, Light_Surge Voltage Suppressor: None, Port Size: -, Thread Type: -, Bracket: -, CE Compliant: -
Body Type: For Manifold, Valve Option: Vacuum Specification Type, Semi-Standard, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 24 VDC, Electrical Entry: w/o Connector, Light_Surge Voltage Suppressor: None, Port Size: -, Thread Type: -, Bracket: -, CE Compliant: -
Body Type: For Manifold, Valve Option: Energy-Saving Type, Vacuum Specification Type, Semi-Standard, Pressure Specifications: High-Pressure Type (1MPa), Semi-Standard, Rated Voltage: 24 VDC, Electrical Entry: w/o Connector, Light_Surge Voltage Suppressor: None, Port Size: -, Thread Type: -, Bracket: -, CE Compliant: -