Example) -DN VVQ2000-FPG06 Manifold (DIN rail mounting style) 2 (B) 4 (A) 2 (B) 4 (A) Caution Since air leakage from the pipe between the valve and cylinder or the fittings will prevent the cylinder from stopping for a long time. Check for air leakage using neutral household detergent, such as dish washing soap.
) ,CF KF(NW),K(D N) XYC KF(NW) KF(NW) KF(NW) KF(NW) K(DN) KF(NW) K(DN) Main material Body: SCS13(Stainless) Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material) Actuation pressure MPa (G) 0.3 to 0.6 0.4 to 0.6 Air consumption cm3 Note 3 At 0.5MPa 38 91 430 280 500 1000 Port size M5 Rc 1/8 XMC 0.36 (0.40) 0.62 1.40(1.76) 2.10 3.80 (5.16) 6.30 Mass kg Note 4 XYC 0.67 1.42
How to Order EX500 G DN 1 Communication protocol Applicable GW unit DN PR AB DeviceNet PROFIBUS-DP Remote I/O (RIO) DeviceNet PROFIBUS-DP Remote I/O (RIO) Nil -X1 Dimensions 148 EX500-GAB1-X1 VOLTAGE 24 VDC/200 mA INPUT/OUTPUT 64/64 IP CODE IP65 SERIAL NO.
-DN Manifold Drop prevention Stoppage in the middle Caution VVQ2000-FPG 06 2 (B) 4 (A) 2 (B) 4 (A) Since air leakage from the pipe between the valve and cylinder or the fittings will prevent the cylinder from stopping for a long time. Check for air leakage using neutral household detergent, such as dish washing soap.
How to Order EX500 G DN 1 Applicable GW unit Communication protocol DeviceNet PROFIBUS-DP Remote I/O (RIO) DN PR AB DeviceNet PROFIBUS-DP Nil Remote I/O (RIO) -X1 Dimensions 148 E x 500-GAB1-X1 VOLTAGE 24VDC/200mA INPUT/OUTPUT 64/64 IP CODE IP65 SERIAL NO.
How to order manifold VV5Q14 P, R port size 08FS0 DN 00T SY 1. How to Order VQ0 VQ1000 VQ2000 1/4 1/4 5/16 Indicate an option symbol, K, for the manifold No. and be sure to specify the mounting position and number of stations of the single and double wiring by means of a manifold specification form.
D-DN This catalog is printed on recycled paper with concern for the global environment.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Stations: 6 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 0 (w/o Input Block), Input Block: w/o Input Block, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 12 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 10 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 5 (Input Block 5 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 12 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 8 (Input Block 8 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 6 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 3 (Input Block 3 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 7 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 4 (Input Block 4 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 4 (Input Block 4 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 7 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 7 (Input Block 7 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 8 Stations, Port Size: LN7 (Top Ported Elbow w/1/4" NPT One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 0 (w/o Input Block), Input Block: w/o Input Block, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)
Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 0 (w/o Input Block), Input Block: w/o Input Block, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: DN (DIN Rail Mount & Name Plate), Option 2: None, US Option: X160US (Preferred US Option)