Do not operate with any parts removed. When the cylinder is operated with any part removed, malfunction will occur and it is very dangerous. c. Although fittings with sealant are used for pipe fittings and plugs, wind them with pipe tape to prevent air leakage when reassembling after position changes.

Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with same. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.

Double Clevis Pivot Bracket Material: Cast iron Z + Stroke DDH10 (hole) B DX 90 B 4 x DT B A DS DH DF 4 x DR DO DO DE DU DU DL DA DC Rotating Angle (mm) Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 50 63 A B A + B + 90 Part no.

Grommet terminal 7 Conduit terminal D With connector DO Without connector L With lead wire LN Without lead wire LO Without connector M With lead wire MN Without lead wire 9 DIN terminal Option L, M plug connector is 220 VAC at the maximum.

Do not drop or bump the product. Dropping or bumping while handling may cause damage to the product. 5. Lead wire dimensions Pressure Supply Warning Covering: 3.4 Insulator: 1.1 Conductor: 0.64 1. Do not use the switch with corrosive gas or liquid. Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch. Operating Environment Warning 2.

In a locked state, do not apply impacts, strong vibrations or rotational forces. Do not apply a impacts, strong vibrations or rotational forces from external sources, because this could damage or shorten the life of the lock unit. 4. The locking of the fine lock cylinder is directional.

In a locked state, do not apply impacts, strong vibrations or rotational forces. Do not apply a impacts, strong vibrations or rotational forces from external sources, because this could damage or shorten the life of the lock unit. 4. The locking of the fine lock cylinder is directional.

Do not operate in locations with an atmosphere of corrosive gases, chemicals, sea water, water or steam, or where the same substances will adhere to the regulator. 2. Do not operate in locations where vibration or impact occurs. 3. In locations under direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off the radiated heat. 5.

Do not use in locations where static electric charges will be a problem. Please consult with SMC regarding use in this kind of environment. 2. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. 3. Do not use in environments where there is direct contact with liquids such as cutting oil, lubricating oil or coolant oil, etc.

Do not press this button, as it can result in damage to the product.

PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.

Do not use in a location having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. Do not use in locations where radiated heat will be received from nearby heat sources. Maintenance Warning 1. Maintenance should be performed in accordance with the procedures in the Operation Manual.

Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bracket mounting Mount the bracket using the mounting screws supplied. The required tightening torque is 0.420.04 Nm.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Refer to the construction drawings for silencer materials. 2. Avoid exposure to direct sunlight. 3. Do not operate in locations where vibration or impact occurs. 4.

Please execute "initialize (refer to P30)" when ITV do not operate normally after restarting the power supply. Please contact us, when ITV do not operate normally after initialize. Reading or writing errors occurred in EEPROM. System error Please contact us when ITV do not operate normally after restarting the power supply. Reading and writing errors occurred in memory.

. * Products with tiny scratches, marks, or display color or brightness variations which do not affect the performance of the product are verified as conforming products.

Do not use the cylinder as a shock absorber. Weight (kg) & Warning ::..;: . ' Bor~ I SZ" (m",) 140 160 "',' 1 .25 Using the cylinder as a shoe\< absorber may cause damage. 6.50 9.07 ! Basic 5.46 i 2. Do not open the cushion valve beyond F, oot . , . 7.49 . , the stopper.

With light/surge voltage suppressor 9 With surge voltage suppressor Other Option Not available for GZ, HZ and DOZ Electrical entry Grommet L plug connector M plug connector DIN terminal G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire D: With connector LN: Without lead wire LO: Without connector MO: Without connector DO

Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39

Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type