<br>Note) Older tanks are subject to unexpected accidents due to internal corrosion caused by external damage or drainage. <br>Depending on the state of the old VBAT series air tank, consider replacing it with a new VBAT series air tank.
<br>This means that when air is not consumed on the outlet side, the outlet pressure becomes 1 MPa.<br>If 0.6 MPa air is constantly consumed at 1500 L/min (ANR) on the outlet side, the booster regulator will run continuously with almost no stopping time, resulting in a reduced service life.<br><br>
<br><br>
<br>②The pressure for driving may not be sufficiently obtained, resulting in the stopping of operation.<br>③ The operation frequency may increase and reduce the service life.
However, the fittings are in compliance with the following JIS standards: <br>For the KQ2 series: B8381-1 <br>For the KF series: B8381-2 <br>“No leakage occurs within 1 minute when the fitting fixed to a tube is underwater while pressurized for 5 minutes at both the max. operating pressure and 0.1 MPa.”
<br>In addition, the release buttons of the KQ2□-□N and KQ2□-□G have a different shape and dimensions from those of the KG series. <br>All KQ2□-□G series fittings with hexagonal sides have a V-shaped groove for discrimination.<br><br>
<br>Silicone, on the other hand, is an artificial compound made from silicon (the main component of siloxane). <br>Is it perhaps silicone that the user sees as a problem? <br>If so, there is only silicone used in the sealant of KQ2 and KQG2 series One-touch fittings. <br>However, silicone is not used in the fitting body or parts other than the seal.
<br>Note 2) Do not use combustible fluids, corrosive fluids, chemicals, poisonous gases, or seawater.<br>Note 3) Also, refer to the AP64 series check valve catalog, which can be found here. Be sure to check the precautions before considering this product.
<br>AN□02 series: It features 35 dB(A) noise reduction, and uses flame-resistant material (equivalent to UL-94 standard V-O) for the main body. Only 1/4, 3/8, and 1/2 port sizes are available. <br>(Reference 1) Standard AN series compact resin type silencer: 30 dB(A) noise reduction
<br>It removes oil mist contained in the exhaust and reduces exhaust noise of compressed air equipment at the same time.<br>Use this product when you want to both remove oil mist contained in the exhaust air from the solenoid valve and reduce the exhaust noise.<br><br>For selection, refer to the AMC series catalog, which can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=silencers-pressure-gauges&fa_id=10851
<br>Note) Production of the “-C1” type was terminated in October 2019; it has since converged with the “-C2” type.<br>G□ pressure gauge catalogs can be found here.
<br>The visibility of the pressure control range can be improved by color-coding the set pressure range (green) and the overall pressure range (red).<br>To set the color zones, remove the cover and adjust the red zone to highlight the set pressure range with the green zone.<br>The green zone setting range depends on the pressure range. Please refer to the catalog for details.
<br>Special order SMC self-align fittings (Model: “-X2” with electroless nickel plating) or commercially available self-align fittings made of stainless steel should be used. In addition, use an ozone-compatible product.<br>We recommend stainless steel for metal tubes and fluoropolymer for resin tubes.<br>However, as deterioration is unavoidable, be sure to replace them regularly.
<br>PFM5/7 series: Nitrogen, argon, and carbon dioxide <br>PF2A, PFMB, PFMC, and PFMV series: Nitrogen <br>Note 1) If argon is used with a flow switch other than one from the PFM5/7 series, errors in the measured values will occur. <br>Note 2) As helium has a low molecular weight, leakage will occur and errors in the measured values will occur.
<br>PF3W series: Ethylene glycol aqueous solution <br>Note) There are limitations regarding the viscosity, concentration, and temperature.<br>PF2D series: Pure water and liquids that do not corrode or permeate Teflon (Refer to the list of applicable fluids in the catalog.)
<br>PF2A, PF2W, and PF2D series: Straight piping with a length of at least 8 times the piping port size <br>LFE series: Straight piping with a length of at least 5 times the piping port size PFMB, PFMC, and PF3W704/720/740/504/520/540 series: Straight piping with a length of 8 cm or longer<br>PF3W711/511 series: Straight PVC piping with a length of 11 cm or longer<br>PF3W721/521 series: Straight
<br>This can be set by selecting the display unit reference when the flow switch is set. <br>Standard: Temperature 20℃, 1 atm (101.3 kPa), Relative humidity 65%<br>Reference: 0℃, 1 atm (101.3 kPa) <br>Note) Only the standard state can be displayed for PFMV series flow switches.
<br>Note 2) This is only applicable to models which can be selected with brackets.
<br>The max. operating pressure differential of the COM. type is smaller than that of the N.C. and N.O. types.<br><br>
<br>The main changes include a wider variety of port sizes, the addition of a high-temperature specification, lower power consumption, and an improved IP rating. <br>Changes have also been made to the port position and appearance.