<br>Check that there is no leakage in the piping, including the customer’s device. If there is no leakage, supply circulating fluid according to section “3.5 Fill of circulating fluid” in the HRS series operation manual. <br>Depending on the problem, however, consider requesting maintenance from a maintenance company. <br>We can recommend service providers if needed.

<br>For details on resetting alarms, refer to section “5.18 (and 5.8) Accumulated Time Reset Function” in the HRS series operation manual, which can be found here. <br>Note that there is no alarm code “AL29” (fan motor maintenance) for water-cooled thermo-chillers. <br>Note 1) Every 30,000 hours for the HRS090 to 200 and the HRSH series

<br>Identify the model, and then refer to the catalog to determine the filtration rating. <br>Note that the nominal filtration accuracy is indicated on the side of sintered elements, and for bag filter elements, it is indicated on the tag at the top of the element.<br><br>

<br>Information on industrial filter selection can be found here.<br>The differences between the 2 are as follows. <br>Seal material: Select from NBR or FKM for the FQ1 series and NBR or fluororesin for the FGD series.<br>Housing material: Only stainless steel 304 is available for the FQ1 series.

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Type, Manual)

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: A (Non-locking Push Type, Manual)

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: YO [DIN Terminal (EN175301-803C) w/o Connector], Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Type, Manual)

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal w/o Connector), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 6 (12 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: YO [DIN Terminal (EN175301-803C) w/o Connector], Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type

Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type