SMC Corporation of America
Elite Part Number Search
Search Results "VHS5510-10A-BS-X1"

Regulator Unit Combination: [Other FRL Combination Devices] Other FRL Combination Device, Port Size: NPT1, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge:

Regulator Unit Combination: [Other FRL Combination Devices] Other FRL Combination Device, Port Size: NPT1, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Reverse Flow (Right to Left)] Right to left, Drain Cock: [Not Provided] No, Pressure Gauge: -

Regulator Unit Combination: [Other FRL Combination Devices] Other FRL Combination Device, Port Size: NPT1, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge:

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8

D-X Individual -X 123 Series MXQ External Dimensions of Adjuster With Shock Absorber (BS/BT) Extension End Body mounting section Table mounting section Q P A D J M H K B F G G E E1 L C MXQ-BS20 (L) MXQ-BS25 (L) MXQ-BS 8 (L) MXQ-BS12 (L) MXQ-BS16 (L) Body mounting section Table mounting section A Stroke adjustment range (mm) Applicable size Model D H J K Q 1) B C F G M E L E1 P *1) M3 x 12

D+1 0 mm Stroke length tolerance -X 20Option Data Extension end (AS) Stroke adjustment Rubber stopper Retraction end (AT) range 0 to 5 mm Both ends (A) Extension end (BS) W/ shock absorber is not available in Series MXQ6.

Without adjuster Adjuster on extension end Adjuster on retraction end Adjuster on both ends Absorber on extension end Absorber on retraction end Absorber on both ends Adjuster on extension end + Absorber on retraction end Absorber on extension end + Adjuster on retraction end Nil AS AT A BS (1) Option Combinations Functional option Nil F R P FR FP Adjuster option BT (1) Nil AS AT A BS BT

Common with the MXQ series. 21 Series MXQR Dimensions: Adjuster Shock absorber (BS, JS, BT, JT) Extension stroke end Body mounting parts Table mounting parts P A D Q M J B H K F MXQR-BS20 MXQR-BS25 G MXQR-BS 8 MXQR-BS12 MXQR-BS16 G E E1 L C Stroke adjustment range (mm) Body mounting parts Table mounting parts A Applicable size Model L E1 B C F G M P 1) H J K Q 1) D E MXQR 6 M2.5 x 8 12.5

BS* X X X BT* X X X X B* X X X X X *End lock and shock absorber options are not available for MXS6 Note 1) When buffer is used in conjunction with extension stroke adjust, stroke adjustment will limit stroke of buffer. Applicable auto switch lead wire length(m) Load voltage Auto switch part No.

Safety cannot be assured in the case of unexpected malfunction. x100 x1 x10 6 Seal cap (for M12 connector socket): 5 pcs.

EX245-DX1 2Byte Table 11-3 X0 X1 X2 X3 X4 X5 X6 X7 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 72 No.EX##-OMY0006CN 11.5. LED EX245-DX1 LED 0 15 OFF ON Fig. 11-2 EX245-DX1 LED 73 No.EX##-OMY0006CN 11.6.

Connecting a wireless adapter (EXW1-A11N-X1) to the M8 "ADPTR" port of the AMS will allow wireless communication. ADPTR port Each of the AMS devices need to be set to pairing mode. Starting with DIP switch 4 of SW 1 in the OFF position, perform the sequence ON >> OFF >> ON. The SF/MS/ST and BF/NS/DIAG/SA LEDs of each device will flash red. Connect to the webserver.

For actuators with a stroke less than 1000mm, set parameter PE02 (Feed function selection) to 0 and the "Feed length multiplication (STM) (Multiplier)" value to x1. For actuators with a stroke more than 1000mm, set parameter PE02 (Feed function selection) to 0001 and the "Feed length multiplication (STM) (Multiplier)" value to x10.

UP/DOWN X1 X2 X4 X4 4 SEL. UP DOWN SEL. (4) FUNC. FUNC. 1 LEFT/RIGH UP/DOWN SEL. SEL. (5) FUNC. FUNC. LEFT/RIGH SET SEL. SET FUNC. FUNC. FUNC. FUNC. -2 SEL. UP LEFT/RIGH OFFSET SEL. UP/DOWN SET SEL. 17 - DOWN -3 FUNC. FUNC. FUNC. FUNC. SEL. LEFT/RIGH STOP SEL. UP/DOWN UP 0.1 SET SEL. DOWN -4 FUNC. FUNC. FUNC. FUNC. SEL. UP/DOWN SET SEL. OUTPUT SEL.

(no condensation and freezing) range Storage humidity 90%RH or less (no condensation) range Note1) Controller initial communication settings Communication speed (bps): 38400 Silent interval: x1 Communication delay time (ms): 5ms Teaching box is automatically recognize the communication speed. 12 - 2.

ECAT ID EtherCAT ID 1999(1) EtherCAT ID: 0999 (Factory default 002) Setting EtherCAT ID x100 x10 x1 0 0 0 Value that setting by EtherCAT master device 0 0 1 1 0 0 2 2 (Factory default) 0 0 6 4 64 9 9 9 999 Caution Turn OFF the power supply while setting the switch.

Switch for setting address X1 and X10 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.

STATION No (X10) 161 (x10) STATION No (X1) (x1) B RATE IF CC-Link F D C 10Mbps B 5Mbps A 2.5Mbps 230.4kbps 9 625kbps 8 156kbps 7 5 4 10Mbps 3 5Mbps 2 2.5Mbps 115.2kbps 1 625kbps 0 156kbps B RATE 1(LEC-T1)IF 115.2kbps 2 15 - 4.2 (CN2SW) CC-Link (CN2SW)CC-Link (CN2SW) () PC/TB (CN2)(LEC-T1-)(LEC-W2)(LEC) (CN2SW)CC-Link (LEC) 16 - 4.3 (LEC) (LEC)(LEC-T1-) (LEC-W2)(LEC) (LEC)(LEC)(

Display Description Detail 1 LED lamp LED to indicate the condition of the gateway unit 2 ADDRESS Address switch This switch sets X1 and X10 in the address. 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.