Rated voltage 1 2 3 4 5 6 7 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC 240 VAC (50/60 Hz) G: Lead wire length 300 mm H: Lead wire length 600 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) D: With connector T: Condait terminal E: Grommet terminal type has been discontinued.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.
to 2100 300 to 2100 +3.00 to +21.00 mA 1: Follow the methods below when assigning the user set upper and lower limit by E.O.
Jointing material Epoxy resin Operating temperature (C) Note 2) 5 to 100 180 to 300 Nominal filtration accuracy (m) 5, 10, 20, 40, 74, 105 Max. differential pressure resistance 0.7 MPa Element replacement differential pressure 0.1 MPa Acid Cannot be used. Can be used. Note 1) Chemical resistance Alkali Can be used. Can be used.
9 Rod seal NBR Basic (B) CM2QB Bore size Stroke (mm) Stroke range 1 to 300 1 to 300 1 to 300 1 to 300 S 65 65 67 91 N 15 15 15 21.5 Bore A 18 22 22 24 B2 26 32 32 41 D 8 10 12 14 H2 8 8 8 10 I 28 33.5 37.5 46.5 ZZ 119 123 125 157 NA 24 30 34.5 42.5 AL 15.5 19.5 19.5 21 E F 13 13 13 16 K 5 5.5 5.5 7 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 B1 13 17 17 22 G 8 8 8 11 MM M8 X 1.25 P 1/8 1/8 1
300 Pressure 0.6 MP 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) 400 400 250 250 0.5 MPa 0.5 MPa 0.5 MPa 0.5 MP 0.5 MPa 0.5 MPa 0.5 MPa 0.5 MP 0.5 MPa 0.5 MPa 0.4 MP 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MP 0.4 MPa 200 200 300 300 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 150 150 0.3 MPa 0.3 MP 0.3 MPa 0.3 MPa 0.3 MP 0.3
300 0.6MPa 0.6MPa 400 400 Holding force (N) Holding force (N) Holding force (N) Holding force (N) 250 250 0.5MPa 0.5MPa 0.5MPa 0.5MPa 0.4MPa 0.4MPa 200 200 300 300 0.4MPa 0.4MPa 0.3MPa 150 150 0.3MPa 0.3MPa 200 200 0.3MPa 100 100 0.2MPa 0.2MPa 0.2MPa 0.2MPa 100 100 50 50 0.1MPa 0.1MPa 0.1MPa 0.1MPa 50 100 150 200 50 100 150 200 0 0 40 80 120 160 200 40 80 120 160 200 0 0 Holding point R
Both directions Lock direction MXW MXP Stroke Bearing Standard stroke (mm) Long stroke (mm) Bore size (mm) MG Model MGP 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Slide bearing 25 350, 400, 450, 500 MGQ 75, 100, 125, 150, 32 350, 400, 450, 500, 600 MLGCL Ball bushing bearing 200, 250, 300 40 350, 400, 450, 500, 600, 700, 800 MGG * Middle strokes and short strokes other than shown
Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.
Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.
Jointing material Epoxy resin Operating temperature (C) Note 2) 5 to 100 180 to 300 Nominal filtration accuracy (m) 5, 10, 20, 40, 74, 105 Max. differential pressure resistance 0.7 MPa Element replacement differential pressure 0.1 MPa Acid Cannot be used. Can be used. Note 1) Chemical resistance Alkali Can be used. Can be used.
M12 Connector Cable (4 Pins) Made by OMRON Part number Cable length [mm] ZS-37-L 300 ZS-37-M 500 ZS-37-N 1000 ZS-37-P 2000 ZS-37-C 5000 Part number Cable length [mm] Changing the entry direction After separating the terminal block and housing, the cord entry can be changed by attaching the housing in the opposite direction 180.
(Houston) 9001 Jameel, Suite 180 Houston, TX77O4O Tel: (713) 460-0762 FAX: (713) 460-1510 SMC Pneumatics Inc. (Tampa) 8507-H Benjamin Road Tampa, FL 33634 Tel: (813) 243-8350 FAX: (813) 243-8621 SMC Pneumatics Inc. (Chicago) 27725 Diehl Road Warrenville, lL 60555 Tel: (630) 393-0080 FAX: (630) 393-0084 SMC Pneumatics Inc. (Portland) 14107 N.E.
(Houston) 9001 Jameel, Suite 180 Houston, TX77O4O Tel: (713) 460-0762 FAX: (713) 460-1510 SMC Pneumatics Inc. (Tampa) 8507-H Benjamin Road Tampa, FL 33634 Tel: (813) 243-8350 FAX: (813) 243-8621 SMC Pneumatics Inc. (Chicago) 27725 Diehl Road Warrenville, lL 60555 Tel: (630) 393-0080 FAX: (630) 393-0084 SMC Pneumatics Inc. (Portland) 14107 N.E.
25, 32, 40, 50, 63 Sine Rodless Cylinder Series 12-REA How to Order Clean series 12 Special treatment on sliding part Bore size (mm) 12 R E A 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Model Port size Lubrication Standard stroke (mm) 12-REA25 12-REA32 25 32 40 Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 200, 250, 300
HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Model Screw type compressor Reciprocating type compressor Screw type compressor 2.2 55 110 7.5 75 22 37 Applicable compressor (kW) 2.2 37 75 7.5 55 15 22 300 8600 18000 1000 12000 3300 5700 (1) Air flow rate l/min(ANR) Reciprocating type compressor 300 5600 11000 1000 8000 2100 4300 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco
If they are not aligned, the connector cannot be joined properly. (3) When the mark B of the connector has been turned 180 degrees (1/2 turn) , wiring is completed. Confirm that the connection is not loose.
Bore size Series CJ2 Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Series MB, CA Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load ratio 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQC1000
VH600 VR Option VH300 VH410 VH VH300/400 Bottom ported VH210 VHS VH200/300/400 Panel mounted All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
Load DOCOM (Note) 24 V DC 10% 300 mA Note. If the voltage drop (maximum of 2.6 V) interferes with the relay operation, apply high voltage (maximum of 26.4 V) from external source. -12- 4. Axis No. settings Set the control axis No. with the rotary switch.