SMC Corporation of America
Elite Part Number Search
Search Results "RZQF40-200-100"

This parameter is fixed when shipped, and cannot be modified. (200) Operation direction Direct3 (dir) or Reverse4 (rvS) can be selected. The default when shipped is direct (dir). setting 100% 200=dir 200=rvS Stroke 0% 0% 100% 0% 100% Input current Fig. 24 When the operation direction is modified, it is reflected on each item in accordance with Table 9.

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2 LECSN2-T 200 to 240 A 10 E2 LECSN2-T-E 200 to 240 92 LECSN2-T-9 200 to 240 I/O cable length P2 LECSN2-T-P 200 to 240 Nil Without cable H Without cable Connector only 1 1.5 [m] Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 -9- AC servo motor LECY* series L E K F S

Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,

Maximum measured Maximum measured Minimum measured Minimum measured Part no. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214

Motor output [W] / size [mm] 100 / 40 200 / 60 Type of Motor AC servo motor (100/200VAC) Type of Motor S2,S3 Incremental 17bit encoder (Resolution:131072 p/rev) Type of Motor S6,S7 Absolute 18bit encoder (Resolution:262144 p/rev) specification Encoder Electric Type of Motor T6,T7 [With LECSB-T/LECSS-T]Absolute 22bit encoder (Resolution: 4194304 p/rev) [With LECSC-T]Absolute 18bit encoder

Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series

cpm] Frequency [cpm] Allowable thrust setting value 150 200 120 250 W = 300 LAT3m-30 4 200 150 200 150 W = 0 W = 100 W = 200 200 150 300 100 W = 0 W = 100 W = 200 3 300 100 600 50 600 50 2 0 0 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 1 Operating condition Model: LAT3F-m Mounting orientation: Horizontal/Vertical Step data

Rating symbol DC 24 VS V100-61-5-05 24 VDC DC 12 VS V100-61-5-06 12 VDC 100/110 VS V100-61-4-01 100 VAC 200/220 VS V100-61-4-02 200 VAC 100/110 VS V100-61-4-01 110 VAC 200/220 VS V100-61-4-02 220 VAC 240 VS V100-61-4-07 240 VAC With Light/Surge Voltage Suppressor Rated voltage Part no.

CL1 200 MLGC CNG 100 500 400 300 200 100 100 500 400 300 200 100 MNB Maximum speed: V (mm/s) Maximum speed: V (mm/s) CNA Graph (6) Graph (3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 2000 600 CNS 500 160 160 CLS 140 400 1000 140 700 800 900 CLQ 125 320 Load mass: m (kg) Load mass: m (kg) 125 300 RLQ 600 500 MLU 400 200 300 MLGP ML1C 200 280 100 100 100 500 400 300 200 100 500 400 300 200

Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.

Movement MOD Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position 0 1: Absolute 100 10 3000 3000 0 0 0 100 0 0 0.50 1 1: Absolute 100 100 3000 3000 0 0 0 100 0 0 0.50 2 1: Absolute 100 200 3000 3000 0 0 0 100 0 0 0.50 Note) The step data input range changes depending on the actuator model.

L N VQ110VQ110YVQ110 ZQ1-VQ120Model Push-locking type Non-locking push type / Locking type (Tool type) Manual override Non-locking push type / Locking type (Tool type) Rated coil voltage 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC 12, 24 VDC DC 100 VAC 110 VAC 200 VAC 220 VAC 1 W 1 W 0.5 W 0.6 VA (6 mA) 0.65 VA (5.9 mA) 1.2 VA (6 mA) 1.3 VA (5.9 mA) Grommet

Note) Air flow capacity (scfm [ANR]) Applicable air compressor (kW) 50 Hz Model Power supply voltage (Frequency) Port size 60 Hz IDF1E 3.53 4.24 0.75 Single-phase 100 VAC (50 Hz) Single-phase 100/110 VAC (60 Hz) IDF2E 7.06 8.30 1.5 Rc3/8 IDF3E 11.3 13.1 2.2 IDF4E 18.4 20.1 3.7 Rc1/2 Single-phase 100/200 VAC (50 Hz) IDF6E 26.5 29.0 5.5 Single-phase 100/110 VAC, 200/220 VAC (60 Hz) IDF8E 43.1

Note 10) A reference value for correcting an error in reciprocal operation. -10- (3) LEMH (Linear guide single axis type) / LEMHT (Linear guide double axis type) Model LEMH25/LEMHT25 LEMH32/LEMHT32 50, 100, 150, 100, 150, 200, 250, 300, Stroke (mm) Note 1) 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, (700), (800), (900), (1000) 350, 400, 450, 500, 550, 600, (700), (800), (900

PA05 100 100 Electronic gear numerator *3. PA06 1 100 35 100 (10) (7) (10) Electronic gear denominator *3.