Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 325, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, Cushion: Rubber cushion, Specification: Built-in magnet, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of
Magnet: Built-in, Mounting: Basic Style, Bore Size: Ø20, Piping: Rc, Stroke: 300mm, Rod Boot: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Mounting bolt C D Flat washer Note) Note) Be sure to use the attached flat washer when mounting a cylinder with through-holes.
For connector with mark C, one piece of cylinder side connector (male) is enclosed. CE1 without connector can be directly connected to terminal block of counter. CE1-ROOC CE1-RO5 CE1-R10 CE1-R15 CE1-R20 CE1-R*C 3.
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a e B part f d z f1 x.Calculate the inertial moment of the attachment. Assuming the attachment material is aluminium alloy (relative density=2.7), r1 = 16.4 (mm).
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
For connector with mark C, one CEP1 without connector can be directly connected to terminal block of counter. piece of cylinder side connector (male) is enclosed.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
Example) -M9NL Symbol Nil A B C Mounting position Valve open/closed Valve open Valve closed Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
Indicator light Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Wiring (Output) Type Special function Electrical entry M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid
(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) Nil XL H0 Solid state auto switch y Number of auto switches/Detecting position XLQ Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
(between lead wire and case) -10C to 60C Ambient temperature Internal circuits Enclosure IEC529 standard IP67, JIS C 0920 watertight construction D-M9N/M9NV Weight Unit: g DC(+) Brown Main switch circuit Model D-M9N(V) D-M9P(V) D-M9B(V) OUT Black 0.5 8 8 7 Lead wire length (m) 3 41 41 38 5 68 68 63 DC(-) Blue How to Order D-M9P/M9PV Standard Model Number DC(+) Brown Main switch circuit Main
Series: CKZ3T, Bore Size: 63 (ø63), Cylinder Port: TP (Rc), Arm Opening Angle: 30°, Proximity Switch: T (TURCK), Top Cover: Rubber Cover, Option: X2734 (Base Type)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: F (Built-in One-touch Fitting), Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m)