SMC Corporation of America
Elite Part Number Search
Search Results "PSE541-M5-C2"

Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, KC, PSE5*1 VAC SWITCH 1/4 PORT PT, .57886 lb

0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JC, PSE5*1 VAC SWITCH 1/8 PORT PT, .24541 lb

Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1C, PSE5*1 VAC SW OTHER SIZE PT, .05222 lb

Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1X, PSE5*1 VAC SW OTHER SIZE(MISC), .14856 lb

Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1X, PSE5*1 VAC SW OTHER SIZE(MISC), .28768 lb

Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1C, PSE5*1 VAC SW OTHER SIZE PT, .15434 lb

Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1C, PSE5*1 VAC SW OTHER SIZE PT, .20214 lb

Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1C, PSE5*1 VAC SW OTHER SIZE PT, .17024 lb

Controller side PLC side For 4 Axes JXC73/83 L JXC C2 (Terminal no.) (R1.25-4) 40 20 39 (7.5) 40 20 Cable length (L) [m] 50.8 1 1.5 3 3 5 5 2 21 1 21 1 Pin no. Wire color Pin no. Wire color Pin no. Wire color Pin no.

B L1 W M2 B side Inch Size 6 4 Model A side B side B C1 C2 E1 E2 H1 H2 L1 L2 M1 M2 Min. port size W Applicable tubing O.D.

1 I/O cable length [m]*3 Compatible driver Power supply voltage [V] Size 25 32 40 Nil Without driver A1 LECSA1-S100 to 120 A2 LECSA2-S200 to 230 B1 LECSB1-S100 to 120 B2 LECSB2-S200 to 230 C1 LECSC1-S100 to 120 C2 LECSC2-S200 to 230 S1 LECSS1-S100 to 120 S2 LECSS2-S200 to 230 *3 When Without driver is selected for driver type, only Nil: Without cable can be selected.

To the communication connector (C2) or (1) of SI unit, connect the branch cable with M12 connector from GW. To the communication connector (C1) or (0), connect the branch cable with M12 connector from Input unit. To the communication connector of Input unit, connect the branch cable with M12 connector from SI unit.

-1.8WDC WF333O Exhaust Conter NVF343O GNced Center (B) (A) (B) (a) 01 c2 \ t \ T I'f E I J E Z (R2)(PxFl) (R2XPXR1) Prssure Center NVF3530 (B) (A) Spej;ifications -, Flurd-Art f Operatangprssurcrange2Positionsingle2O-12gPSlS(1.5-9kgF) U 2 pooition double-1 5 1 28 PSI (1 9kgf/cm'?

A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits

A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits

Number of connecting tubes Accessory (Option) How to Use 6 12 Nil C1 C2 None Cover single side 1 pc. Cover both sides 2 pcs. 6 12 Caution K Disassembly (1) Loosen clamp ring and disassemble the connector into the plug case and socket case. Style Tubing O.D.

C1: With connector cable (Length 300 mm) C2: With connector cable (Length 600 mm) C3: With connector cable (Length 1000 mm) Note) The applicable tube of the barb fitting shows the tube outside diameter/inside diameter.

Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: Standard (w/Light Surge Voltage Suppressor)(+COM), Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm)

Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm), Bracket: F (With Bracket)

Valve Stations: 04 (4 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm), Bracket: F (With Bracket)