Body Type: Manifold, Valve Option: for Vacuum, Voltage: 24 VDC, Electrical Entry: Conduit Terminal, Light & Surge Suppressor: -, Port Size: -, Thread: -, CE/UKCA Compliant: -
Function: 2 Position Single, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Port Size: -
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 5, Cable Option: T (Centralized Lead Wired, w/Bracket)
Valve Size: 16, Control Power Supply: None, Voltage: 5 (24VDC), Electrical Entry: T (Terminal), CE Marked: None
Valve Size: 25, Control Power Supply: None, Voltage: 5 (24VDC), Electrical Entry: T (Terminal), CE Marked: None
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: N (NPT)
Function: 4 (3 Position Exhaust Center), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: N (NPT)
Function: 2 (2 Position Double), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping)
Function: 3 (3 Position Closed Center), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: B02 (Base Mounted w/Sub-plate 1/4, Bottom Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: N (NPT)